Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets

View through CrossRef
To simplify the cross-calibration process and improve calibration frequency and accuracy, this paper proposes a cross-calibration method for the multispectral remote sensor Multi-Spectral Instrument (MSI) carried by Sentinel-2B using the hyperspectral remote sensor, that is, the satellite calibration spectrometer (SCS) carried by Hai Yang (HY)-1C, as the reference sensor and establishes the calibration process. Precise spectral response matching between SCS and MSI spectral channels is performed by the interpolation and iteration of hyperspectral data to eliminate the difference in band settings and significantly improve the accuracy of cross-calibration coefficients. The SNO-x inherited from the simultaneous nadir overpass (SNO) method is used as a prediction method to carry out cross-calibration imaging in mid- and low-latitude regions, which improves the cross-calibration frequency and broadens the dynamic range of calibration. The cross-calibration coefficients and offsets of MSI B1∼B7 and B8a were obtained by processing the earth observation images of the MSI and SCS on January 24, 2019. Then, the cross-calibration coefficients and offsets are applied to the ocean, farmland and other ground objects with different reflectance, and the reliability and accuracy of the cross-calibration results are evaluated with the Moderate-resolution Imaging Spectroradiometer (MODIS) carried by Terra as a reference. To improve the accuracy of the evaluation, the spectral band adjustment factor between the corresponding channels of MSI and MODIS is used to correct the measured reflectance of MODIS based on the satellite calibration coefficient. The reflectance directly obtained by processing the MSI image is used as the MSI-measured reflectance, the reflectance obtained based on the cross-calibration coefficient is used as the MSI-calculated reflectance, and the reflectance corrected by the spectral band adjustment factor (SBAF) is used as the MODIS-calculated reflectance. The results show that the mean root-mean-square relative error (RMSRE) between the MODIS-calculated reflectance and the MSI-calculated reflectance is 2.16% and that the mean RMSRE between the MODIS-calculated reflectance and the MSI-measured reflectance is 3.05%, indicating that the reflectance corrected based on calibration coefficients is closer to the MODIS-calculated reflectance. Finally, each uncertainty source in the cross-calibration is analyzed, and the comprehensive uncertainty is found to be 4.03%, indicating that SCS can be used as a reference for MSI cross-calibration.
Title: Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
Description:
To simplify the cross-calibration process and improve calibration frequency and accuracy, this paper proposes a cross-calibration method for the multispectral remote sensor Multi-Spectral Instrument (MSI) carried by Sentinel-2B using the hyperspectral remote sensor, that is, the satellite calibration spectrometer (SCS) carried by Hai Yang (HY)-1C, as the reference sensor and establishes the calibration process.
Precise spectral response matching between SCS and MSI spectral channels is performed by the interpolation and iteration of hyperspectral data to eliminate the difference in band settings and significantly improve the accuracy of cross-calibration coefficients.
The SNO-x inherited from the simultaneous nadir overpass (SNO) method is used as a prediction method to carry out cross-calibration imaging in mid- and low-latitude regions, which improves the cross-calibration frequency and broadens the dynamic range of calibration.
The cross-calibration coefficients and offsets of MSI B1∼B7 and B8a were obtained by processing the earth observation images of the MSI and SCS on January 24, 2019.
Then, the cross-calibration coefficients and offsets are applied to the ocean, farmland and other ground objects with different reflectance, and the reliability and accuracy of the cross-calibration results are evaluated with the Moderate-resolution Imaging Spectroradiometer (MODIS) carried by Terra as a reference.
To improve the accuracy of the evaluation, the spectral band adjustment factor between the corresponding channels of MSI and MODIS is used to correct the measured reflectance of MODIS based on the satellite calibration coefficient.
The reflectance directly obtained by processing the MSI image is used as the MSI-measured reflectance, the reflectance obtained based on the cross-calibration coefficient is used as the MSI-calculated reflectance, and the reflectance corrected by the spectral band adjustment factor (SBAF) is used as the MODIS-calculated reflectance.
The results show that the mean root-mean-square relative error (RMSRE) between the MODIS-calculated reflectance and the MSI-calculated reflectance is 2.
16% and that the mean RMSRE between the MODIS-calculated reflectance and the MSI-measured reflectance is 3.
05%, indicating that the reflectance corrected based on calibration coefficients is closer to the MODIS-calculated reflectance.
Finally, each uncertainty source in the cross-calibration is analyzed, and the comprehensive uncertainty is found to be 4.
03%, indicating that SCS can be used as a reference for MSI cross-calibration.

Related Results

(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
Introduction Heterogeneous gas sensor arrays coupled with machine learning algorithms have been proposed for a wide range of applications. However, i...
Multi-Resolution Ocean Color roducts to support the Copernicus Marine High-Resolution Coastal Service 
Multi-Resolution Ocean Color roducts to support the Copernicus Marine High-Resolution Coastal Service 
High-quality satellite-based ocean colour products can provide valuable support and insights in the management and monitoring of coastal ecosystems. Today’s availability ...
Clinical and epigenetic features of colorectal cancer patients with somatic POLE proofreading mutations
Clinical and epigenetic features of colorectal cancer patients with somatic POLE proofreading mutations
Abstract Background Mutations in the POLE gene result in an ultra-hypermutated phenotype in colorectal cancer (CRC); however, the molecular characte...
High-Frequency versus Conventional Spinal Cord Stimulation in Patients with Failed-Back Surgery Syndrome
High-Frequency versus Conventional Spinal Cord Stimulation in Patients with Failed-Back Surgery Syndrome
Objective: Failed-back surgery syndrome (FBSS) is characterized by chronic pain and disability. Spinal cord stimulation (SCS) is a viable treatment option, with conventional SCS (C...
Abstract 7560: Microsatellite instability (MSI) detection using flow-based sequencing
Abstract 7560: Microsatellite instability (MSI) detection using flow-based sequencing
Abstract Background: Microsatellite instability (MSI) is an important genomic biomarker associated with various cancers and hereditary conditions. Accurate and effic...
Cross-modal interactions between auditory attention and oculomotor control
Cross-modal interactions between auditory attention and oculomotor control
Abstract Microsaccades are small, involuntary eye movements that occur during fixation. Their role is debated with recent hypotheses proposing a contribution to aut...
Microsatellite unstable gastrointestinal neuroendocrine carcinomas: a new clinicopathologic entity
Microsatellite unstable gastrointestinal neuroendocrine carcinomas: a new clinicopathologic entity
Gastroenteropancreatic (GEP) neuroendocrine carcinomas (NECs) and mixed adenoneuroendocrine carcinomas (MANECs) are heterogeneous neoplasms characterized by poor outcome. Microsate...

Back to Top