The Effect of the Accuracy of Various Measuring Devices on Recorded Joint Kinematics
View through CrossRef
Knowledge of joint kinematics contributes to the understanding of the function of soft tissue restraints, injury mechanisms, and can be used to evaluate surgical repair techniques. (Tibone, McMahon et al. 1998; Karduna, McClure et al. 2001; Abramowitch, Papageorgiou et al. 2003) Previous studies have measured joint kinematics using a variety of non-invasive methods that include: optical tracking, magnetic tracking, and mechanical linkage systems. (Rudins, Laskowski et al. 1997; Apreleva, Hasselman et al. 1998; Gabriel, Wong et al. 2004) These measurement devices report kinematics of rigid bodies with respect their own global coordinate system. However, it is often useful to understand these kinematics in terms of a coordinate system whose axes coincide with the degrees of freedom of each specific joint (anatomical coordinate systems). Once the kinematics are obtained with respect to the global coordinate system of the measurement device, the joint kinematics can be calculated with respect to anatomical coordinate systems if the relationship between the measurement device and the anatomical coordinate systems are known. Although the accuracy of these kinematic measurement devices is provided by the manufacturer, the effect of their accuracy on joint kinematics reported with respect to anatomical coordinate systems must be determined. (Panjabi, Goel et al. 1982; Crisco, Chen et al. 1994) For example, small errors in orientation of the measurement system could lead to large errors in position for an anatomical coordinate system located at some distance away. As researchers report joint kinematics with respect to the anatomical coordinate systems, understanding the errors produced by one’s measurement device with respect to the anatomical coordinate systems is necessary. Further, a great deal of interest exists for studying knee joint kinematics. (Sakane, Livesay et al. 1999; Lephart, Ferris et al. 2002; Ford, Myer et al. 2003) Within our research center our goal is to collect knee joint kinematics of a cadaver and reproduce them with respect to the anatomical coordinate systems using robotic technology. Therefore, the objective of this study was to determine the effect of the accuracy of three measurement devices (optical tracking device-OptoTrak® 3020, magnetic tracking device-Flock of Birds®, instrumented spatial linkage-EnduraTec Corp.) on knee joint kinematics reported with respect to an anatomical coordinate system.
Title: The Effect of the Accuracy of Various Measuring Devices on Recorded Joint Kinematics
Description:
Knowledge of joint kinematics contributes to the understanding of the function of soft tissue restraints, injury mechanisms, and can be used to evaluate surgical repair techniques.
(Tibone, McMahon et al.
1998; Karduna, McClure et al.
2001; Abramowitch, Papageorgiou et al.
2003) Previous studies have measured joint kinematics using a variety of non-invasive methods that include: optical tracking, magnetic tracking, and mechanical linkage systems.
(Rudins, Laskowski et al.
1997; Apreleva, Hasselman et al.
1998; Gabriel, Wong et al.
2004) These measurement devices report kinematics of rigid bodies with respect their own global coordinate system.
However, it is often useful to understand these kinematics in terms of a coordinate system whose axes coincide with the degrees of freedom of each specific joint (anatomical coordinate systems).
Once the kinematics are obtained with respect to the global coordinate system of the measurement device, the joint kinematics can be calculated with respect to anatomical coordinate systems if the relationship between the measurement device and the anatomical coordinate systems are known.
Although the accuracy of these kinematic measurement devices is provided by the manufacturer, the effect of their accuracy on joint kinematics reported with respect to anatomical coordinate systems must be determined.
(Panjabi, Goel et al.
1982; Crisco, Chen et al.
1994) For example, small errors in orientation of the measurement system could lead to large errors in position for an anatomical coordinate system located at some distance away.
As researchers report joint kinematics with respect to the anatomical coordinate systems, understanding the errors produced by one’s measurement device with respect to the anatomical coordinate systems is necessary.
Further, a great deal of interest exists for studying knee joint kinematics.
(Sakane, Livesay et al.
1999; Lephart, Ferris et al.
2002; Ford, Myer et al.
2003) Within our research center our goal is to collect knee joint kinematics of a cadaver and reproduce them with respect to the anatomical coordinate systems using robotic technology.
Therefore, the objective of this study was to determine the effect of the accuracy of three measurement devices (optical tracking device-OptoTrak® 3020, magnetic tracking device-Flock of Birds®, instrumented spatial linkage-EnduraTec Corp.
) on knee joint kinematics reported with respect to an anatomical coordinate system.
Related Results
ANALISIS INFORMASI ANATOMI PENGGUNAAN PROYEKSI SKYLINE PADA PEMERIKSAAN KNEE JOINT POST ARTHROSCOPY
ANALISIS INFORMASI ANATOMI PENGGUNAAN PROYEKSI SKYLINE PADA PEMERIKSAAN KNEE JOINT POST ARTHROSCOPY
Latar belakang: knee Joint atau sendi lutut merupakan salah satu sendi terbesar dalam tubuh, sendi ini merupakan sendi yang kompleks. Osteoarthritis merupakan kelainan sendi degene...
Adjacent Joint Kinematics after Ankle Arthrodesis in Cadaveric Gait Simulation
Adjacent Joint Kinematics after Ankle Arthrodesis in Cadaveric Gait Simulation
Category:
Ankle Arthritis
Introduction/Purpose:
Ankle arthrodesis is an effective ...
Effects of Calcaneal Osteotomies on Gait Kinematics in Simulated Progressive Collapsing Foot Deformity: A Cadaveric Study
Effects of Calcaneal Osteotomies on Gait Kinematics in Simulated Progressive Collapsing Foot Deformity: A Cadaveric Study
Background:
Calcaneal osteotomies are often used to correct hindfoot valgus and forefoot abduction in patients with PCFD. Calcaneal osteotomies are commonly per...
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Abstract
Thoracic outlet syndrome (TOS) is a complex and often overlooked condition caused by the compression of neurovascular structures as they pass through the thoracic outlet. ...
Influence of Tibial Component Position on Altered Kinematics Following Total Ankle Arthroplasty During Simulated Gait
Influence of Tibial Component Position on Altered Kinematics Following Total Ankle Arthroplasty During Simulated Gait
Category:
Ankle Arthritis
Introduction/Purpose:
Correct positioning of total ankle...
Ankle and Hindfoot Kinematics After Total Ankle Arthroplasty in Cadaveric Gait Simulation
Ankle and Hindfoot Kinematics After Total Ankle Arthroplasty in Cadaveric Gait Simulation
Category:
Ankle Arthritis.
Introduction/Purpose:
Total ankle arthroplasty (TAA) is...
The Ankle-Hindfoot Kinematics of Current Generation Total Ankle Replacement: A Cadaveric Gait Simulation
The Ankle-Hindfoot Kinematics of Current Generation Total Ankle Replacement: A Cadaveric Gait Simulation
Category:
Ankle Arthritis
Introduction/Purpose:
Total ankle replacement (TAR) has ...
KINEMATICS OF SPERMATOZOA IN FRESH AND FROZEN SEMEN OF PESISIR CATTLE
KINEMATICS OF SPERMATOZOA IN FRESH AND FROZEN SEMEN OF PESISIR CATTLE
This study aimed to evaluate the quality and kinematics of spermatozoa in fresh and frozen semen of coastal cattle. Semen of coastal cattle was collected using an artificial vagina...