Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Assessment of cranial reconstruction utilizing various implant materials: finite element study

View through CrossRef
AbstractThe human head can sometimes experience impact loads that result in skull fractures or other injuries, leading to the need for a craniectomy. Cranioplasty is a procedure that involves replacing the removed portion with either autologous bone or alloplastic material. While titanium has traditionally been the preferred material for cranial implants due to its excellent properties and biocompatibility, its limitations have prompted the search for alternative materials. This research aimed to explore alternative materials to titanium for cranial implants in order to address the limitations of titanium implants and improve the performance of the cranioplasty process. A 3D model of a defective skull was reconstructed with a cranial implant, and the implant was simulated using various stiff and soft materials (such as alumina, zirconia, hydroxyapatite, zirconia-reinforced PMMA, and PMMA) as alternatives to titanium under 2000N impact forces. Alumina and zirconia implants were found to reduce stresses and strains on the skull and brain compared to titanium implants. However, PMMA implants showed potential for causing skull damage under current loading conditions. Additionally, PMMA and hydroxyapatite implants were prone to fracture. Despite these findings, none of the implants exceeded the limits for tensile and compressive stresses and strains on the brain. Zirconia-reinforced PMMA implants were also shown to reduce stresses and strains on the skull and brain compared to PMMA implants. Alumina and zirconia show promise as alternatives to titanium for the production of cranial implants. The use of alternative implant materials to titanium has the potential to enhance the success of cranial reconstruction by overcoming the limitations associated with titanium implants. Graphical Abstract
Title: Assessment of cranial reconstruction utilizing various implant materials: finite element study
Description:
AbstractThe human head can sometimes experience impact loads that result in skull fractures or other injuries, leading to the need for a craniectomy.
Cranioplasty is a procedure that involves replacing the removed portion with either autologous bone or alloplastic material.
While titanium has traditionally been the preferred material for cranial implants due to its excellent properties and biocompatibility, its limitations have prompted the search for alternative materials.
This research aimed to explore alternative materials to titanium for cranial implants in order to address the limitations of titanium implants and improve the performance of the cranioplasty process.
A 3D model of a defective skull was reconstructed with a cranial implant, and the implant was simulated using various stiff and soft materials (such as alumina, zirconia, hydroxyapatite, zirconia-reinforced PMMA, and PMMA) as alternatives to titanium under 2000N impact forces.
Alumina and zirconia implants were found to reduce stresses and strains on the skull and brain compared to titanium implants.
However, PMMA implants showed potential for causing skull damage under current loading conditions.
Additionally, PMMA and hydroxyapatite implants were prone to fracture.
Despite these findings, none of the implants exceeded the limits for tensile and compressive stresses and strains on the brain.
Zirconia-reinforced PMMA implants were also shown to reduce stresses and strains on the skull and brain compared to PMMA implants.
Alumina and zirconia show promise as alternatives to titanium for the production of cranial implants.
The use of alternative implant materials to titanium has the potential to enhance the success of cranial reconstruction by overcoming the limitations associated with titanium implants.
Graphical Abstract.

Related Results

Implant‐Abutment Interface: Biomechanical Study of Flat Top versus Conical
Implant‐Abutment Interface: Biomechanical Study of Flat Top versus Conical
ABSTRACT Background: Overloading has been identified as a primary factor behind dental implant failure. The peak bone stresses normally appear in the marginal bone. The anchorage s...
Influence of Roxolid Implant Material on The Implant Stability of Maxillary Implant Retained Overdenture
Influence of Roxolid Implant Material on The Implant Stability of Maxillary Implant Retained Overdenture
Abstract Background Long-term success of implant restoration depends on many factors one of them is the sufficient implant stability which is lowered in compromised bone d...
Soft tissue reconstructive techniques at implant sites
Soft tissue reconstructive techniques at implant sites
Dental implants have shown to be a reliable tool for single, multiple and full-arch rehabilitations 1. Dental implants have a very high success rate in terms of osseointegration, h...
Soft tissue features of peri‐implant diseases and related treatment
Soft tissue features of peri‐implant diseases and related treatment
AbstractBackgroundThe need for soft tissue grafting at implant sites for preventing and treating peri‐implant diseases is a currently investigated and debated topic.PurposeThe aim ...
Dental Implant Abutments and Their Selection - A Review
Dental Implant Abutments and Their Selection - A Review
Dental implants have become the most promising and accepted prosthetic alternative to missing teeth. Innovative and technological advances in implant dentistry have improved the pe...

Back to Top