Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Influence of Roxolid Implant Material on The Implant Stability of Maxillary Implant Retained Overdenture

View through CrossRef
Abstract Background Long-term success of implant restoration depends on many factors one of them is the sufficient implant stability which is lowered in compromised bone density sites such as the maxilla as it is categorized as type III & IV bone, so searching for a new innovation and updates in implant material and features is very mandatory. So, the aim of this study was to compare between two implant materials (roxolid and traditional titanium) on the primary and secondary stability of implant retained maxillary overdenture. Methods Eighteen completely edentulous patients were selected. All patients received maxillary implant-retained overdentures and lower complete dentures; patients were divided equally into two groups according to the type of implant materials. Group A received a total number of 36 implants made of roxolid material and Group B received a total number of 36 implants made of traditional titanium alloys. Implant stability was assessed using ostell device, the primary implant stability was measured at the day of implant installation however, secondary implant stability was measured after six weeks of implant placement. Paired t-test was used to compare between primary and secondary stability in the same group and an independent t-test was used to compare between the two groups with a significant level < 0.05. Results Independent t-test revealed a significant difference between the two groups with p -value = 0.0141 regarding primary stability and p-value < 0.001 regarding secondary stability, as roxolid implant group was statistically higher stability than titanium group in both. Paired t- test showed a statistically significant difference in roxolid implant group with p-value = 0.0122 however, there was non-statistically significant difference in titanium group with p-value = 0.636. Mann Whitney test showed a significant difference between the two groups regarding amount of change in stability with p value = 0.191. roxolid implant group showed a higher amount of change in stability than the titanium implant group. Conclusion Within the limitation of this study, it could be concluded that: Roxolid implants showed better primary and secondary stability than conventional titanium one in implant retained maxillary overdenture. Trial registration: NCT06334770 at 27-3-2024.
Title: Influence of Roxolid Implant Material on The Implant Stability of Maxillary Implant Retained Overdenture
Description:
Abstract Background Long-term success of implant restoration depends on many factors one of them is the sufficient implant stability which is lowered in compromised bone density sites such as the maxilla as it is categorized as type III & IV bone, so searching for a new innovation and updates in implant material and features is very mandatory.
So, the aim of this study was to compare between two implant materials (roxolid and traditional titanium) on the primary and secondary stability of implant retained maxillary overdenture.
Methods Eighteen completely edentulous patients were selected.
All patients received maxillary implant-retained overdentures and lower complete dentures; patients were divided equally into two groups according to the type of implant materials.
Group A received a total number of 36 implants made of roxolid material and Group B received a total number of 36 implants made of traditional titanium alloys.
Implant stability was assessed using ostell device, the primary implant stability was measured at the day of implant installation however, secondary implant stability was measured after six weeks of implant placement.
Paired t-test was used to compare between primary and secondary stability in the same group and an independent t-test was used to compare between the two groups with a significant level < 0.
05.
Results Independent t-test revealed a significant difference between the two groups with p -value = 0.
0141 regarding primary stability and p-value < 0.
001 regarding secondary stability, as roxolid implant group was statistically higher stability than titanium group in both.
Paired t- test showed a statistically significant difference in roxolid implant group with p-value = 0.
0122 however, there was non-statistically significant difference in titanium group with p-value = 0.
636.
Mann Whitney test showed a significant difference between the two groups regarding amount of change in stability with p value = 0.
191.
roxolid implant group showed a higher amount of change in stability than the titanium implant group.
Conclusion Within the limitation of this study, it could be concluded that: Roxolid implants showed better primary and secondary stability than conventional titanium one in implant retained maxillary overdenture.
Trial registration: NCT06334770 at 27-3-2024.

Related Results

Awareness about Roxolid Implants among Dental Students
Awareness about Roxolid Implants among Dental Students
Roxolid implants are endosseous root form implants made of alloy comprising 85% Titanium and 15% Zirconium. This unique combination greatly improves the tensile and fatigue strengt...
The influence of mandibular implant‐retained overdentures in masticatory efficiency
The influence of mandibular implant‐retained overdentures in masticatory efficiency
doi: 10.1111/j.1741‐2358.2011.00539.xThe influence of mandibular implant‐retained overdentures in masticatory efficiencyObjective:  To evaluate the masticatory efficiency of patien...
Observation of the effect on immediate mandibular implant-supported overdenture of micro implant system of Italy
Observation of the effect on immediate mandibular implant-supported overdenture of micro implant system of Italy
The study was design to investigate the clinical effect of Micro implant system in Italy on immediate mandibular implant-supported overdenture. A total of 192 patients with mandibu...
Mandibular Magnet Retained Complete Overdenture
Mandibular Magnet Retained Complete Overdenture
Background: Complete denture in the lower jaw often has problems. The entire loss of the mandibular teeth often has a large resorption, so it is difficult to obtain retention and s...
Studies on maxillary overdentures: implant- and prosthesis survival, cost analysis and patient-reported outcomes
Studies on maxillary overdentures: implant- and prosthesis survival, cost analysis and patient-reported outcomes
Edentulism is a debilitating condition which may negatively affect quality of life, particularly in relation to nutritional and social health, speech, and poor facial appearance. P...
Swallowing dynamics of two implants versus single implant-retained mandibular overdentures: randomized clinical trial
Swallowing dynamics of two implants versus single implant-retained mandibular overdentures: randomized clinical trial
Objective This study evaluated the swallowing dynamics of two-implant (2-IOD) versus singleimplant (1-IOD) mandibular overdentures using the Test of Mastication and Swallowing Soli...
Tooth Supported Overdenture as Prosthetic Solution for Elderly Patients: A Case Series
Tooth Supported Overdenture as Prosthetic Solution for Elderly Patients: A Case Series
Overdenture treatment is a notion which precludes the inevitability of “floating plastic” in edentulous mouths. The concept of tooth retained overdenture is a simple and cost effec...
Relationship of Maxillary Sinus and Maxillary First Molar Root Using Cone Beam Computed Tomography
Relationship of Maxillary Sinus and Maxillary First Molar Root Using Cone Beam Computed Tomography
Background: Cone beam CT (CBCT) is an advancement of conventional CT that uses a divergent pyramidal or conical X-ray beam for imaging the craniofacial complex. Studies on the maxi...

Back to Top