Javascript must be enabled to continue!
Implant‐Abutment Interface: Biomechanical Study of Flat Top versus Conical
View through CrossRef
ABSTRACT Background: Overloading has been identified as a primary factor behind dental implant failure. The peak bone stresses normally appear in the marginal bone. The anchorage strength is maximized if the implant is given a design that minimizes the peak bone stress caused by a standardized load. Clinical studies have shown that it is possible to obtain a marginal bone level close to the crest of the implant. Different implant systems make use of different designs of the implant‐abutment interface. Different implant‐abutment interfaces imply that the functional load is distributed in different ways upon the implant. According to Saint‐Venant's principle, this will result in different stress patterns in the marginal bone when this reaches levels close to the implant crest. Purpose: One aim of the study was to theoretically investigate if a conical implant‐abutment interface gives rise to a changed stress pattern in the marginal bone, as compared to a flat top interface, for an axially loaded mandibular titanium implant, the neck of which is provided with retention elements giving effective interlocking with the bone. Further aims were to investigate if the way in which the axial load is distributed on the flat top and on the inner conus respectively affects the stress pattern in the marginal bone. The pertinent stress was considered to be the bone‐implant interfacial shear stress. It was assumed that the marginal bone reached the level of the implant–abutment interface. Method: The investigation was performed by means of axisymmetric finite element analysis. Results: The conical implant‐abutment interface of the type studied brought about a decrease in the peak bone‐implant interfacial shear stress as compared to the flat top interface of the type studied. This peak interfacial shear stress was located at the top marginal bone for the flat top implant‐abutment interface whereas it was located more apically in the bone for the conical implant‐abutment interface. The way in which the axial load was distributed on the flat top and on the inner conus respectively affected the peak interfacial shear stress level. Conclusion: The design of the implant‐abutment interface has a profound effect upon the stress state in the marginal bone when this reaches the level of this interface. The implant with the conical interface can theoretically resist a larger axial load than the implant with the flat top interface.
Title: Implant‐Abutment Interface: Biomechanical Study of Flat Top versus Conical
Description:
ABSTRACT Background: Overloading has been identified as a primary factor behind dental implant failure.
The peak bone stresses normally appear in the marginal bone.
The anchorage strength is maximized if the implant is given a design that minimizes the peak bone stress caused by a standardized load.
Clinical studies have shown that it is possible to obtain a marginal bone level close to the crest of the implant.
Different implant systems make use of different designs of the implant‐abutment interface.
Different implant‐abutment interfaces imply that the functional load is distributed in different ways upon the implant.
According to Saint‐Venant's principle, this will result in different stress patterns in the marginal bone when this reaches levels close to the implant crest.
Purpose: One aim of the study was to theoretically investigate if a conical implant‐abutment interface gives rise to a changed stress pattern in the marginal bone, as compared to a flat top interface, for an axially loaded mandibular titanium implant, the neck of which is provided with retention elements giving effective interlocking with the bone.
Further aims were to investigate if the way in which the axial load is distributed on the flat top and on the inner conus respectively affects the stress pattern in the marginal bone.
The pertinent stress was considered to be the bone‐implant interfacial shear stress.
It was assumed that the marginal bone reached the level of the implant–abutment interface.
Method: The investigation was performed by means of axisymmetric finite element analysis.
Results: The conical implant‐abutment interface of the type studied brought about a decrease in the peak bone‐implant interfacial shear stress as compared to the flat top interface of the type studied.
This peak interfacial shear stress was located at the top marginal bone for the flat top implant‐abutment interface whereas it was located more apically in the bone for the conical implant‐abutment interface.
The way in which the axial load was distributed on the flat top and on the inner conus respectively affected the peak interfacial shear stress level.
Conclusion: The design of the implant‐abutment interface has a profound effect upon the stress state in the marginal bone when this reaches the level of this interface.
The implant with the conical interface can theoretically resist a larger axial load than the implant with the flat top interface.
Related Results
Dental Implant Abutments and Their Selection - A Review
Dental Implant Abutments and Their Selection - A Review
Dental implants have become the most promising and accepted prosthetic alternative to missing teeth. Innovative and technological advances in implant dentistry have improved the pe...
REUSE OF THE INTRAOSSEOUS PART OF THE DENTAL IMPLANT (THE CLINICAL CASE)
REUSE OF THE INTRAOSSEOUS PART OF THE DENTAL IMPLANT (THE CLINICAL CASE)
Introduction. Replacement of a small included defect in the frontal area with a fixed structure based on the implant is the optimal solution. It is not always required to remove th...
Stress analysis in implant, abutment, and peripheral bone with different restorative crown and abutment materials: A three-dimensional finite element analysis study
Stress analysis in implant, abutment, and peripheral bone with different restorative crown and abutment materials: A three-dimensional finite element analysis study
Background:
Stresses on prosthetic crown directly influences the survival rate of implants hence it should be considered while selecting prosthetic material.
...
Factors Influencing Marginal Bone Loss around Dental Implants: A Narrative Review
Factors Influencing Marginal Bone Loss around Dental Implants: A Narrative Review
Implant supported dental prostheses are increasingly used in dental practice. The aim of this narrative review is to present the influence of transmucosal surface of prosthetic abu...
<span style="mso-ansi-language: EN;">Retrieval of Fractured Abutment Screw of Dental Implant. Case Report<span style="font-size: 10.0pt; mso-ansi-font-size: 18.0pt; font-family: 'Times New Roman',serif; mso-ascii-font-family: 'Palatino Linotype';
<span style="mso-ansi-language: EN;">Retrieval of Fractured Abutment Screw of Dental Implant. Case Report<span style="font-size: 10.0pt; mso-ansi-font-size: 18.0pt; font-family: 'Times New Roman',serif; mso-ascii-font-family: 'Palatino Linotype';
Background: The advancement of dental implants marks a significant milestone in modern dentistry, offering an effective solution for tooth replacement while improving both function...
Evaluation of Peri-implant Bone Change and its Risk Factors in Patients Presenting to a Medical Center: A 7-year Cross-sectional Study
Evaluation of Peri-implant Bone Change and its Risk Factors in Patients Presenting to a Medical Center: A 7-year Cross-sectional Study
<p>Abstract: Objective: To evaluate the amount of peri-implant bone loss detected on digital panoramic radiographs in patient presenting to Chi-Mei medical center and to det...
Soft tissue reconstructive techniques at implant sites
Soft tissue reconstructive techniques at implant sites
Dental implants have shown to be a reliable tool for single, multiple and full-arch rehabilitations 1. Dental implants have a very high success rate in terms of osseointegration, h...
Influence of Roxolid Implant Material on The Implant Stability of Maxillary Implant Retained Overdenture
Influence of Roxolid Implant Material on The Implant Stability of Maxillary Implant Retained Overdenture
Abstract
Background
Long-term success of implant restoration depends on many factors one of them is the sufficient implant stability which is lowered in compromised bone d...