Javascript must be enabled to continue!
Digital tomosynthesis spot view in architectural distortions: outcomes in management and radiation dose
View through CrossRef
Abstract
Purpose
To evaluate if digital breast tomosynthesis spot compression view (DBT-SCV) could be an additional projection to confirm or deny architectural distortions (ADs) detected by digital breast tomosynthesis (DBT) while assessing the average glandular radiation dose.
Methods
This is a retrospective cohort study enrolling 8864 DBT exams, of which only cases detecting primary AD and with BI-RADS 2–5 score were considered. Seventy-one AD cases examined with DBT-SCV, US and MRI were evaluated for correlation in terms of BI-RADS score; variables among exams were assessed for inter-relationships.
Results
Of all ADs identified at DBT, biopsy yielded malignancy in only 38%. PPV in identifying malignancy of ADs was higher for DBT-SCV than DBT (p < 0.05); the NPV of DBT-SCV was 94%. The difference between DBT and DBT-SCV in the detection of benign ADs was statistically significant (p < 0.05). AD without US or MRI confirmation was less likely to represent malignancy (p < 0.05). In detecting malignant cases of ADs, both DBT and DBT-SCV were strongly correlated with US and RM (Kappa > 0.90). In identifying benign cases of ADs, DBT-SCV was poorly/moderately correlated with US and RM (Kappa 0.25 and 0.66); DBT was negatively correlated with US and MRI.
Conclusion
DBT-SCV could be useful to better characterize AD firstly identified by DBT, keeping dose levels within the reference limits. If AD is detected by DBT without an US or MRI correlate, that is not confirmed by DBT-SCV, a “wait and see” approach can be applied to reduce unnecessary biopsy.
Springer Science and Business Media LLC
Title: Digital tomosynthesis spot view in architectural distortions: outcomes in management and radiation dose
Description:
Abstract
Purpose
To evaluate if digital breast tomosynthesis spot compression view (DBT-SCV) could be an additional projection to confirm or deny architectural distortions (ADs) detected by digital breast tomosynthesis (DBT) while assessing the average glandular radiation dose.
Methods
This is a retrospective cohort study enrolling 8864 DBT exams, of which only cases detecting primary AD and with BI-RADS 2–5 score were considered.
Seventy-one AD cases examined with DBT-SCV, US and MRI were evaluated for correlation in terms of BI-RADS score; variables among exams were assessed for inter-relationships.
Results
Of all ADs identified at DBT, biopsy yielded malignancy in only 38%.
PPV in identifying malignancy of ADs was higher for DBT-SCV than DBT (p < 0.
05); the NPV of DBT-SCV was 94%.
The difference between DBT and DBT-SCV in the detection of benign ADs was statistically significant (p < 0.
05).
AD without US or MRI confirmation was less likely to represent malignancy (p < 0.
05).
In detecting malignant cases of ADs, both DBT and DBT-SCV were strongly correlated with US and RM (Kappa > 0.
90).
In identifying benign cases of ADs, DBT-SCV was poorly/moderately correlated with US and RM (Kappa 0.
25 and 0.
66); DBT was negatively correlated with US and MRI.
Conclusion
DBT-SCV could be useful to better characterize AD firstly identified by DBT, keeping dose levels within the reference limits.
If AD is detected by DBT without an US or MRI correlate, that is not confirmed by DBT-SCV, a “wait and see” approach can be applied to reduce unnecessary biopsy.
Related Results
Access Denied
Access Denied
Introduction
As social-distancing mandates in response to COVID-19 restricted in-person data collection methods such as participant observation and interviews, researchers turned t...
Staging of breast cancer and the advanced applications of digital mammogram: what the physician needs to know?
Staging of breast cancer and the advanced applications of digital mammogram: what the physician needs to know?
Objective:
To study the role of advanced applications of digital mammogram, whether contrast-enhanced spectral mammography (CESM) or digital breast tomosynthesis ...
Correcting geometric image distortions in slice‐based 4D‐MRI on the MR‐linac
Correcting geometric image distortions in slice‐based 4D‐MRI on the MR‐linac
PurposeThe importance of four‐dimensional‐magnetic resonance imaging (4D‐MRI) is increasing in guiding online plan adaptation in thoracic and abdominal radiotherapy. Many 4D‐MRI se...
Unusual Presentation of Alice in Wonderland Syndrome: A Case Report and Literature Review
Unusual Presentation of Alice in Wonderland Syndrome: A Case Report and Literature Review
Abstract
Introduction
Alice in Wonderland Syndrome (AIWS) is an uncommon and frequently overlooked neuropsychiatric condition, marked by brief episodes of altered visual and somato...
Low-dose, X-ray-based Imaging of Lung Function
Low-dose, X-ray-based Imaging of Lung Function
<p>Chronic obstructive pulmonary disease (COPD) is characterized by chronic airflow limitation resulting from emphysema and small airway disease. Functional lung imaging of C...
Low-dose, X-ray-based Imaging of Lung Function
Low-dose, X-ray-based Imaging of Lung Function
<p>Chronic obstructive pulmonary disease (COPD) is characterized by chronic airflow limitation resulting from emphysema and small airway disease. Functional lung imaging of C...
SU‐FF‐I‐113: Anatomical Power Spectrum and Detectability: An Analytical and Experimental Basis
SU‐FF‐I‐113: Anatomical Power Spectrum and Detectability: An Analytical and Experimental Basis
Purpose: Superposition of anatomical clutter in medical images is known to degrade detectability of underlying structures. This paper investigates background power spectrum (PS) in...
COMPARISON OF RADIATION DOSE FOR TWO DIGITAL RADIOGRAPHIC SYSTEM IN CORONARY ANGIOGRAPHY PROCEDURE
COMPARISON OF RADIATION DOSE FOR TWO DIGITAL RADIOGRAPHIC SYSTEM IN CORONARY ANGIOGRAPHY PROCEDURE
Objectives
To evaluate the radiation dose to patients using flat-panel detector (FPD) and image intensifier charge-coupled device (II-CCD) digital radiographic sy...

