Javascript must be enabled to continue!
SU‐FF‐I‐113: Anatomical Power Spectrum and Detectability: An Analytical and Experimental Basis
View through CrossRef
Purpose: Superposition of anatomical clutter in medical images is known to degrade detectability of underlying structures. This paper investigates background power spectrum (PS) in tomosynthesis and cone‐beam CT (CBCT) in a manner that is general to various applications (e.g., breast and chest imaging) and allows analysis of generalized noise‐equivalent quanta (GNEQ) and task‐specific detectability. Methods: An analytical basis for physical phantom design was established from principles of self‐similarity and fractal dimension. Random arrangements of equal volumes of spheres were found to present power‐law noise comparable to that of, for example, breast or chest imaging. Rectangular and cylindrical phantoms containing spheres of various diameter (3–16 mm) were configured on an experimental bench for tomosynthesis and CBCT. Background PS was analyzed as a function of orbital extent, ranging from ∼10°–360°. Results were fit to the empirical form K/f∧b and incorporated in the GNEQ to investigate detectability versus tomosynthesis arc, imaging task, and dose. Results: Clutter phantoms based on self‐similar collections of spheres provided background PS described well by power‐law noise. 3D background PS were highly asymmetric, subtending the tomosynthesis arc in the Fourier domain and scales with the number of backprojected views. Analysis of the fully 3D background PS yields K and b that vary with tomosynthesis angle in a manner consistent with expectations, is distinct from that previously analyzed in 2D slices, and highlights the effect of orbital extent on 3D detectability. Analysis of GNEQ identified total arc and dose required to achieve a given level of detectability, depending on the imaging task. Conclusions: An analytical basis drawn from fractal theory guided phantom design providing power‐law noise. Analysis of background PS, GNEQ, and detectability index over a broad range of system configurations provided a general basis pertinent to modality‐specific systems, such as breast and chest tomosynthesis and CBCT.
Title: SU‐FF‐I‐113: Anatomical Power Spectrum and Detectability: An Analytical and Experimental Basis
Description:
Purpose: Superposition of anatomical clutter in medical images is known to degrade detectability of underlying structures.
This paper investigates background power spectrum (PS) in tomosynthesis and cone‐beam CT (CBCT) in a manner that is general to various applications (e.
g.
, breast and chest imaging) and allows analysis of generalized noise‐equivalent quanta (GNEQ) and task‐specific detectability.
Methods: An analytical basis for physical phantom design was established from principles of self‐similarity and fractal dimension.
Random arrangements of equal volumes of spheres were found to present power‐law noise comparable to that of, for example, breast or chest imaging.
Rectangular and cylindrical phantoms containing spheres of various diameter (3–16 mm) were configured on an experimental bench for tomosynthesis and CBCT.
Background PS was analyzed as a function of orbital extent, ranging from ∼10°–360°.
Results were fit to the empirical form K/f∧b and incorporated in the GNEQ to investigate detectability versus tomosynthesis arc, imaging task, and dose.
Results: Clutter phantoms based on self‐similar collections of spheres provided background PS described well by power‐law noise.
3D background PS were highly asymmetric, subtending the tomosynthesis arc in the Fourier domain and scales with the number of backprojected views.
Analysis of the fully 3D background PS yields K and b that vary with tomosynthesis angle in a manner consistent with expectations, is distinct from that previously analyzed in 2D slices, and highlights the effect of orbital extent on 3D detectability.
Analysis of GNEQ identified total arc and dose required to achieve a given level of detectability, depending on the imaging task.
Conclusions: An analytical basis drawn from fractal theory guided phantom design providing power‐law noise.
Analysis of background PS, GNEQ, and detectability index over a broad range of system configurations provided a general basis pertinent to modality‐specific systems, such as breast and chest tomosynthesis and CBCT.
Related Results
Detectability of an intermediate layer by magnetotelluric sounding
Detectability of an intermediate layer by magnetotelluric sounding
Abstract
The recent publication by Verma and Mallick (1979) on the detectability of an intermediate layer by time domain EM sounding provides some informative ans...
Uudissanoja
Uudissanoja
Kielenaineksetajoittaa (kieli: suomi, sivulla: 112)alisteinen (kieli: suomi, sivulla: 112)emälaiva (kieli: suomi, sivulla: 113)emälippu (kieli: suomi, sivulla: 113)ennakoida (kieli...
Isolation, characterization and semi-synthesis of natural products dimeric amide alkaloids
Isolation, characterization and semi-synthesis of natural products dimeric amide alkaloids
Isolation, characterization of natural products dimeric amide alkaloids from roots of the Piper chaba Hunter. The synthesis of these products using intermolecular [4+2] cycloaddit...
Improving Detectability of Illegal Fishing Activities Across Supply Chains
Improving Detectability of Illegal Fishing Activities Across Supply Chains
Abstract
Improving detectability (i.e., enforcers’ capacity to detect illegal fishing activities) is crucial for fisheries management, food security and livelihoods. Identi...
A phantom study for ground-glass nodule detectability using chest digital tomosynthesis with iterative reconstruction algorithm by ten observers: association with radiation dose and nodular characteristics
A phantom study for ground-glass nodule detectability using chest digital tomosynthesis with iterative reconstruction algorithm by ten observers: association with radiation dose and nodular characteristics
Objective:
To compare detectability of simulated ground-glass nodules (GGNs) on chest digital tomosynthesis (CDT) among 12 images obtained at 6 radiation doses us...
Malleable Anatomies
Malleable Anatomies
Malleable Anatomies examines the early stages of the practice of anatomical modelling. It investigates the ‘mania’ for anatomical displays that swept the Italian peninsula in the m...
The second four-electron singlet in the Hubbard impurity model
The second four-electron singlet in the Hubbard impurity model
We consider the energy operator of four-electron systems in the Hubbard impurity model and investigate the structure of the essential spectrum and discrete spectra for the second s...
Distance sampling and the challenge of monitoring butterfly populations
Distance sampling and the challenge of monitoring butterfly populations
Summary1. Abundance indices generated by the UK Butterfly Monitoring Scheme (UKBMS) have been influential in informing our understanding of environmental change and highlighting UK...

