Javascript must be enabled to continue!
COMPARISON OF RADIATION DOSE FOR TWO DIGITAL RADIOGRAPHIC SYSTEM IN CORONARY ANGIOGRAPHY PROCEDURE
View through CrossRef
Objectives
To evaluate the radiation dose to patients using flat-panel detector (FPD) and image intensifier charge-coupled device (II-CCD) digital radiographic system in coronary angiography procedure.
Methods
Radiation dose and dose rate with FPD and II-CCD digital radiographic system in coronary angiography procedure were measured using a phantom and radiation detector. Measurements were carried out for three times with each digital radiographic system, and the arithmetic were calculated.
Results
For fluoroscopy, the phantom radiation dose with FPD digital radiographic system was reduced by 5.6% compared to II-CCD digital radiographic system. However, for digital cineangiography, the phantom radiation dose with FPD digital radiographic system was increased by 7.8%. Compared to II-CCD digital radiographic system, the total phantom radiation dose with FPD digital radiographic system were increased by 2.3% for completing the coronary angiography procedure.
Conclusions
This study demonstrates that, compared to II-CCD digital radiographic system, the phantom radiation dose and dose rates with FPD digital radiographic system were reduced for fluoroscopy during coronary angiography, but increased for digital cineangiography. The same increase was also observed for the total phantom radiation dose with FPD digital radiographic system. These findings suggest that, compared with II-CCD digital radiographic system, FPD digital radiographic system did not inherently reduce the radiation dose, although FPD digital radiographic system possess good detective quantum efficiency.
Title: COMPARISON OF RADIATION DOSE FOR TWO DIGITAL RADIOGRAPHIC SYSTEM IN CORONARY ANGIOGRAPHY PROCEDURE
Description:
Objectives
To evaluate the radiation dose to patients using flat-panel detector (FPD) and image intensifier charge-coupled device (II-CCD) digital radiographic system in coronary angiography procedure.
Methods
Radiation dose and dose rate with FPD and II-CCD digital radiographic system in coronary angiography procedure were measured using a phantom and radiation detector.
Measurements were carried out for three times with each digital radiographic system, and the arithmetic were calculated.
Results
For fluoroscopy, the phantom radiation dose with FPD digital radiographic system was reduced by 5.
6% compared to II-CCD digital radiographic system.
However, for digital cineangiography, the phantom radiation dose with FPD digital radiographic system was increased by 7.
8%.
Compared to II-CCD digital radiographic system, the total phantom radiation dose with FPD digital radiographic system were increased by 2.
3% for completing the coronary angiography procedure.
Conclusions
This study demonstrates that, compared to II-CCD digital radiographic system, the phantom radiation dose and dose rates with FPD digital radiographic system were reduced for fluoroscopy during coronary angiography, but increased for digital cineangiography.
The same increase was also observed for the total phantom radiation dose with FPD digital radiographic system.
These findings suggest that, compared with II-CCD digital radiographic system, FPD digital radiographic system did not inherently reduce the radiation dose, although FPD digital radiographic system possess good detective quantum efficiency.
Related Results
DUAL-AXIS ROTATIONAL CORONARY ANGIOGRAPHY CAN REDUCE PEAK SKIN DOSE AND SCATTERED DOSE: A PHANTOM STUDY
DUAL-AXIS ROTATIONAL CORONARY ANGIOGRAPHY CAN REDUCE PEAK SKIN DOSE AND SCATTERED DOSE: A PHANTOM STUDY
Objectives
to evaluate the peak skin dose received by the patient and scattered dose to the operator during the dual-axis rotational coronary angiography and comp...
e0543 Clinical and coronary angiography characteristics between young (<45) and old (>60) patients with coronary artery disease
e0543 Clinical and coronary angiography characteristics between young (<45) and old (>60) patients with coronary artery disease
Objective
To study the clinical Clinical and coronary angiography characteristics between young (≤45) and old (>60) patients with coronary artery disease.
...
e0425 Clinical and coronary angiography characteristics between young (≤45) and old (>60) patients with coronary artery disease
e0425 Clinical and coronary angiography characteristics between young (≤45) and old (>60) patients with coronary artery disease
Objective
To study the clinical Clinical and coronary angiography characteristics between young (≤45) and old (>60) patients with coronary artery disease.
...
Assessing the Appropriateness and Effectiveness of Coronary CT Angiography in COVID-19 Patients with Chest Pain
Assessing the Appropriateness and Effectiveness of Coronary CT Angiography in COVID-19 Patients with Chest Pain
Coronary CT Angiography (CCTA) is well established for Chest Pain (CP) evaluation to assess coronary artery stenosis. However, the appropriateness of CCTA for COVID-19 patients wit...
Coronary angiography of the ex‐situ beating donor heart in a portable organ care system
Coronary angiography of the ex‐situ beating donor heart in a portable organ care system
AbstractObjectivesTo determine safety and feasibility of ex‐situ coronary angiography.BackgroundTo cater for the perpetually growing demand for heart donors, interest in donation f...
CT-Coronary Angiography
CT-Coronary Angiography
A large body of literature has demonstrated the ability of coronary computed tomographic (CT) angiography to rule out significant stenosis. This test is a non-invasive alternative ...
THE EFFECT OF ATROVASTATIN ON THE QRS DURATION IN THE PATIENTS WITH ACUTE ANTERIOR ST ELEVATION MYOCARDIAL INFARCTION UNDERGOING PRIMARY ANGIOPLASTY
THE EFFECT OF ATROVASTATIN ON THE QRS DURATION IN THE PATIENTS WITH ACUTE ANTERIOR ST ELEVATION MYOCARDIAL INFARCTION UNDERGOING PRIMARY ANGIOPLASTY
Objectives
To evaluate the value of intensive atorvastatin treatment on changes of QRS duration and ventricular arrhythmia in the patients with acute anterior ST ...
THE SAFETY AND EFFICACY OF DUAL-AXIS ROTATIONAL CORONARY ANGIOGRAPHY IN THE DIAGNOSIS OF CORONARY ARTERY DISEASE
THE SAFETY AND EFFICACY OF DUAL-AXIS ROTATIONAL CORONARY ANGIOGRAPHY IN THE DIAGNOSIS OF CORONARY ARTERY DISEASE
Objectives
Standard coronary angiography (SA) is performed in multiple stationary views at different angles around the patient to evaluate the severity and locati...

