Research on Voltage Regulation Methods for Flexible On‐Load Tap‐Changing Transformers

View through CrossRef
ABSTRACT This paper investigates the fundamental principles of voltage regulation and commutation failure mitigation for flexible power transformer (FPT). By introducing a voltage source converter (VSC) with adjustable amplitude is inserted between the high‐voltage winding terminal and the ground of the main transformer, dynamic voltage regulation is achieved, which enhances the commutation voltage and mitigating commutation failure. The steady‐state control strategy of the VSC and a compensation strategy for DC commutation failure are developed. When a voltage drop caused by grid disturbances is detected and a commutation failure occurs in the DC transmission system, the converter activates its compensation function to inject a voltage either in phase or in opposition to the transformer's high‐voltage winding voltage, thereby increasing the commutation voltage, reducing the commutation angle, extending the arc extinction period and improving the overall reliability of DC transmission. Furthermore, simulation studies are conducted for a typical ± 800 kV/10,000 MW ultrahigh‐voltage direct current (UHVDC) transmission project, validating the effectiveness and accuracy of the proposed control strategy.
Institution of Engineering and Technology (IET)
Title: Research on Voltage Regulation Methods for Flexible On‐Load Tap‐Changing Transformers
Description:
ABSTRACT This paper investigates the fundamental principles of voltage regulation and commutation failure mitigation for flexible power transformer (FPT).
By introducing a voltage source converter (VSC) with adjustable amplitude is inserted between the high‐voltage winding terminal and the ground of the main transformer, dynamic voltage regulation is achieved, which enhances the commutation voltage and mitigating commutation failure.
The steady‐state control strategy of the VSC and a compensation strategy for DC commutation failure are developed.
When a voltage drop caused by grid disturbances is detected and a commutation failure occurs in the DC transmission system, the converter activates its compensation function to inject a voltage either in phase or in opposition to the transformer's high‐voltage winding voltage, thereby increasing the commutation voltage, reducing the commutation angle, extending the arc extinction period and improving the overall reliability of DC transmission.
Furthermore, simulation studies are conducted for a typical ± 800 kV/10,000 MW ultrahigh‐voltage direct current (UHVDC) transmission project, validating the effectiveness and accuracy of the proposed control strategy.

Related Results

On the Remote Calibration of Instrumentation Transformers: Influence of Temperature
On the Remote Calibration of Instrumentation Transformers: Influence of Temperature
The remote calibration of instrumentation transformers is theoretically possible using synchronous measurements across a transmission line with a known impedance and a local set of...
CREATION OF A STRUCTURAL MODEL OF AN POWER TRANSFORMERS IN THE FORM OF AC TRANSFORMING COMPLEXES
CREATION OF A STRUCTURAL MODEL OF AN POWER TRANSFORMERS IN THE FORM OF AC TRANSFORMING COMPLEXES
Due to the multiple transformation of electrical energy, the rated capacity of power transformers can be 8 or more times the rated generation capacity. Therefore, the state of reli...
The influence of harmonics from non-linear loads in the measuring transformers of electrical substations.
The influence of harmonics from non-linear loads in the measuring transformers of electrical substations.
 The  mainstreams  of  research  papers  developed  to  analysis  of  electrical  systems power  quality  for  non-linear  loads  are  conducted  for  low  voltage  feed.  This,  i...
Control Relay Circuit of Dynamic Load Balancer on Medium Voltage Distribution Line
Control Relay Circuit of Dynamic Load Balancer on Medium Voltage Distribution Line
The distribution of electricity is commonly done in 3 phase radial network or loop type system. The voltage varies from 34 KV (Kilovolts) down to 13.8 or 11 KV. The single-phase tr...
Crane Load Moment System For Offshore Crane Operations
Crane Load Moment System For Offshore Crane Operations
Abstract History has shown that dependency upon the crane operator to monitor loads and boom angle or load radius do not allow the margin necessary to perform the...
Optimal operation of paralleled power transformers
Optimal operation of paralleled power transformers
Parallel operation of power transformers is a common practice. Interest is placed on minimizing the reactive current circulation between transformers due to mismatching of electric...
Assessment and Mitigation Studies of Voltage Sags during Sympathetic Inrush Current
Assessment and Mitigation Studies of Voltage Sags during Sympathetic Inrush Current
The system voltage may be negatively impacted by the transformer’s energisation which draws a large value of magnetising inrush current for a few seconds. During the transformer’s ...