The influence of harmonics from non-linear loads in the measuring transformers of electrical substations.

View through CrossRef
 The  mainstreams  of  research  papers  developed  to  analysis  of  electrical  systems power  quality  for  non-linear  loads  are  conducted  for  low  voltage  feed.  This,  if  in  one  hand  have furnished important results about the performance of power quality provide by installation, in other hand drops off bad quality effects of electrical energy in high and medium voltage distribution net, mainly in effects of harmonics components, in principals apparatus in substations entrance, notably in current and voltage transformers employed to feed protection and measuring systems of installa-tion.  This  paper  explains  conclusions  of  a  comparative  analysis  of  voltage  and  currents  behavior and  harmonics  components  between  voltage  in  secondary  feed  side  and  primary  feed  side  of  a medium voltage substation. In this way, the objective of research is contributed to a better under-standing  of  measurement  transformers  behavior  and  his  influence  in  measuring,  protection  and control, when installed in equipment with predominance of non-linear loads. The  objective  of  paper  is  identifying  the  error  that  can  be  present  in  electrical  parameters  of substation,  when measuring in medium or high voltage are used. With this proposal was building an experimental substation in Power Quality Laboratory of Sao Paulo State University. The installa-tion is composite by 2 distribution transformers, 30 kVA, 13,800 / 220 V, connect in substation entry and other in outlet. Between transformers exist 3 current transformers and 2 voltage transformers and also surge arresters and monophase disconnectors. The load was welding machines, resistors and gas discharge high pressure sodium lamps, used in public illumination and industrial installa-tions. The results demonstrate that exist an intense influence of non-linear loads in medium voltage when measuring with current or voltage transformers.
Title: The influence of harmonics from non-linear loads in the measuring transformers of electrical substations.
Description:
 The  mainstreams  of  research  papers  developed  to  analysis  of  electrical  systems power  quality  for  non-linear  loads  are  conducted  for  low  voltage  feed.
 This,  if  in  one  hand  have furnished important results about the performance of power quality provide by installation, in other hand drops off bad quality effects of electrical energy in high and medium voltage distribution net, mainly in effects of harmonics components, in principals apparatus in substations entrance, notably in current and voltage transformers employed to feed protection and measuring systems of installa-tion.
 This  paper  explains  conclusions  of  a  comparative  analysis  of  voltage  and  currents  behavior and  harmonics  components  between  voltage  in  secondary  feed  side  and  primary  feed  side  of  a medium voltage substation.
In this way, the objective of research is contributed to a better under-standing  of  measurement  transformers  behavior  and  his  influence  in  measuring,  protection  and control, when installed in equipment with predominance of non-linear loads.
The  objective  of  paper  is  identifying  the  error  that  can  be  present  in  electrical  parameters  of substation,  when measuring in medium or high voltage are used.
With this proposal was building an experimental substation in Power Quality Laboratory of Sao Paulo State University.
The installa-tion is composite by 2 distribution transformers, 30 kVA, 13,800 / 220 V, connect in substation entry and other in outlet.
Between transformers exist 3 current transformers and 2 voltage transformers and also surge arresters and monophase disconnectors.
The load was welding machines, resistors and gas discharge high pressure sodium lamps, used in public illumination and industrial installa-tions.
The results demonstrate that exist an intense influence of non-linear loads in medium voltage when measuring with current or voltage transformers.

Related Results

Harmonics In Offshore Electrical Power System
Harmonics In Offshore Electrical Power System
Abstract Recently Electrical Submersible Pumps (ESPs) are being widely used in the depleting oil fields with low pressure (Dead Crude) and in deep wells with marg...
CREATION OF A STRUCTURAL MODEL OF AN POWER TRANSFORMERS IN THE FORM OF AC TRANSFORMING COMPLEXES
CREATION OF A STRUCTURAL MODEL OF AN POWER TRANSFORMERS IN THE FORM OF AC TRANSFORMING COMPLEXES
Due to the multiple transformation of electrical energy, the rated capacity of power transformers can be 8 or more times the rated generation capacity. Therefore, the state of reli...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
FIELD INVESTIGATIONS INTO HARMONICS POLLUTION AFFECTING TRANSFORMERS
FIELD INVESTIGATIONS INTO HARMONICS POLLUTION AFFECTING TRANSFORMERS
Field investigations on harmonics caused by loads are essential to have a quantitative visualization and formation of premise of research. Field investigations have been carried ou...
Sea Loads On Floating Offshore Systems
Sea Loads On Floating Offshore Systems
ABSTRACT High frequency and low frequency nonlinear wave loads on large volume offshore structures are discussed. The importance of ringing are pointed out. Mathe...
On the Remote Calibration of Instrumentation Transformers: Influence of Temperature
On the Remote Calibration of Instrumentation Transformers: Influence of Temperature
The remote calibration of instrumentation transformers is theoretically possible using synchronous measurements across a transmission line with a known impedance and a local set of...
Evaluasi Metode Health Index Untuk Menentukan Prioritas Pemeliharaan Gardu Distribusi
Evaluasi Metode Health Index Untuk Menentukan Prioritas Pemeliharaan Gardu Distribusi
Electricity is an essential energy source that plays a crucial role in human life. A key component of power distribution systems is the distribution substation. As distribution sub...
Harmonic Assessment in Jordanian Low-Voltage Electrical Power Grid
Harmonic Assessment in Jordanian Low-Voltage Electrical Power Grid
With the proliferation of nonlinear loads in the power system, harmonic pollution becomes a serious problem that affects the power quality in both transmission and distribution sys...