Control Relay Circuit of Dynamic Load Balancer on Medium Voltage Distribution Line

View through CrossRef
The distribution of electricity is commonly done in 3 phase radial network or loop type system. The voltage varies from 34 KV (Kilovolts) down to 13.8 or 11 KV. The single-phase transformers are evenly distributed or connected along the system, that causes unbalance loading to the system as the load behavior of the customers is dynamically changing. Due to these unbalance loading, the voltage at the sending end is adjusted by the distribution operator to compensate for the unbalance. The voltage regulator (VR) used has a maximum tap setting capacity that when the unbalance occurs and beyond the capability of the VR, the unbalance voltage will be imminent. Therefore, the operator has no option, although this can rarely happen, but to change the physical connection of a few single-phase transformers connected to the system to correct the unbalances. Power interruption is needed to execute the desired connection of the single-phase transformer, and the duration varies depending on the type of connector used. Hotline clamps are commonly used along overhead lines but sometimes wedge type or clamp connector is used. The process of removing and transferring the transformer leads and, in most cases, the primary leads are either long or short to the new phase and therefore is not efficient and the safety of personnel is always in question as this is done with the live line procedure when hot line clamp was utilized. This research paper investigated the potential of a new hardware to be permanently connected to all the single-phase transformers that can facilitate the needed changing of phase connection should the unbalance in the system be beyond the VR tap setting limits and the on-load tap changer (OLTC) of the substation transformer. The aim of this new hardware design is to have a fast and efficient way to transfer the phase connection of single-phase transformers to any desired phase (AB, BC, or CA). The research is currently limited to the control unit using electromechanical relays and timers.
Title: Control Relay Circuit of Dynamic Load Balancer on Medium Voltage Distribution Line
Description:
The distribution of electricity is commonly done in 3 phase radial network or loop type system.
The voltage varies from 34 KV (Kilovolts) down to 13.
8 or 11 KV.
The single-phase transformers are evenly distributed or connected along the system, that causes unbalance loading to the system as the load behavior of the customers is dynamically changing.
Due to these unbalance loading, the voltage at the sending end is adjusted by the distribution operator to compensate for the unbalance.
The voltage regulator (VR) used has a maximum tap setting capacity that when the unbalance occurs and beyond the capability of the VR, the unbalance voltage will be imminent.
Therefore, the operator has no option, although this can rarely happen, but to change the physical connection of a few single-phase transformers connected to the system to correct the unbalances.
Power interruption is needed to execute the desired connection of the single-phase transformer, and the duration varies depending on the type of connector used.
Hotline clamps are commonly used along overhead lines but sometimes wedge type or clamp connector is used.
The process of removing and transferring the transformer leads and, in most cases, the primary leads are either long or short to the new phase and therefore is not efficient and the safety of personnel is always in question as this is done with the live line procedure when hot line clamp was utilized.
This research paper investigated the potential of a new hardware to be permanently connected to all the single-phase transformers that can facilitate the needed changing of phase connection should the unbalance in the system be beyond the VR tap setting limits and the on-load tap changer (OLTC) of the substation transformer.
The aim of this new hardware design is to have a fast and efficient way to transfer the phase connection of single-phase transformers to any desired phase (AB, BC, or CA).
The research is currently limited to the control unit using electromechanical relays and timers.

Related Results

ANALISIS PENGUJIAN RELAY PROTEKSI MENGGUNAKAN RELAY TESTING UNIT TIPE PTE-100-C PLUS
ANALISIS PENGUJIAN RELAY PROTEKSI MENGGUNAKAN RELAY TESTING UNIT TIPE PTE-100-C PLUS
Relay proteksi adalah suatu relay listrik yang digunakan untuk mengamankan peralatan-peralatan listrik terhadap kondisi abnormal. Banyaknya karakteristik beban dan penambahan beban...
Proposal Topologies of RF Rectifiers Using 65nm TSMC MOS Technology
Proposal Topologies of RF Rectifiers Using 65nm TSMC MOS Technology
Radio-Frequency Energy Harvesting (RFEH) can be considered a promising solution for powering devices in the Internet of Things era, such as low-power wireless sensors, since RF ele...
Study on Anatomycal Structure of Watergum Wood (<i>Syzygium </i>sp.)
Study on Anatomycal Structure of Watergum Wood (<i>Syzygium </i>sp.)
<!--[if gte mso 9]><xml> <w:WordDocument> <w:View>Normal</w:View> <w:Zoom>0</w:Zoom> <w:TrackMoves /> <w:TrackFormatting /> &l...
A CHINA E A TRANSIÇÃO SOCIALISTA – UM BREVE BOSQUEJO
A CHINA E A TRANSIÇÃO SOCIALISTA – UM BREVE BOSQUEJO
<!--[if gte mso 9]><xml> <o:DocumentProperties> <o:Revision>0</o:Revision> <o:TotalTime>0</o:TotalTime> <o:Pages>1</o:Pages> &...
Three Dimensional Simulations in Real Time for Personalized Drug Release Prosthesis Used in Lumbosacral Rehabilitation
Three Dimensional Simulations in Real Time for Personalized Drug Release Prosthesis Used in Lumbosacral Rehabilitation
This paper presents a theoretical method for simulation and three-dimensional reconstruction of the anatomical elements of the spine in order to achieve hydrogel disc prosthesis by...

Back to Top