Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Pengaruh Panjang Sambungan Pada Beton Prategang Segmental Bertulangan Limbah Ban

View through CrossRef
Prestressed concrete with reinforcement of waste tires can improve significantly the flexural strength. The problems when applied in the project is difficult to move from the production site to the location of the structure. One method to overcome this is applied precast segmental. Molded concrete blocks with a shorter length is easy to carry to the project site. Connectors between concrete beams segment plays a very important thing. This study tried to determine the influence of length of connectors on the precast segmental concrete. Three specimens are concrete beam with no connections, segmental concrete blocks with a connection length of 10 cm and 15 used in the experiment. Flexural testing was conducted to determine the carrying capacity of the three beams. The result showed that the length of the connection contribute on flexural strength of concrete beam. However, segmental concrete beam flexural capacity was still below the concrete beam flexural capacity without connection.Beton prategang bertulangan limbah ban dapat meningkatkan kuat lentur yang cukup besar. Kendalanya ketika diaplikasikan di lapangan adalah kesulitan memindahkan dari tempat pengecoran ke lokasi struktur. Salah satu metode untuk mengatasi ini digunakanlah pracetak segmental. Balok beton dicetak dengan ukuran panjang yang pendek sehingga mudah dibawa ke lokasi proyek. Penyambung antara segmen balok beton memegang peranan yang sangat penting. Studi ini mencoba mengetahui pengaruh panjang sambungan pada jenis sambungan yang sudah tertentu. Tiga buah benda uji yaitu balok beton tanpa sambungan, balok beton segmental dengan panjang sambungan 10 cm dan 15 digunakan dalam eksperimen. Pengujian lentur dilakukan untuk mengetahui kapasitas dukung ketiga balok tersebut. Hasilnya menunjukkan bahwa panjang sambungan berpengaruh terhadap kuat lentur balok beton segemental. Namun kapasistas lentur balok beton segmental masih dibawah kapasitas lentur balok beton tanpa sambungan.
Title: Pengaruh Panjang Sambungan Pada Beton Prategang Segmental Bertulangan Limbah Ban
Description:
Prestressed concrete with reinforcement of waste tires can improve significantly the flexural strength.
The problems when applied in the project is difficult to move from the production site to the location of the structure.
One method to overcome this is applied precast segmental.
Molded concrete blocks with a shorter length is easy to carry to the project site.
Connectors between concrete beams segment plays a very important thing.
This study tried to determine the influence of length of connectors on the precast segmental concrete.
Three specimens are concrete beam with no connections, segmental concrete blocks with a connection length of 10 cm and 15 used in the experiment.
Flexural testing was conducted to determine the carrying capacity of the three beams.
The result showed that the length of the connection contribute on flexural strength of concrete beam.
However, segmental concrete beam flexural capacity was still below the concrete beam flexural capacity without connection.
Beton prategang bertulangan limbah ban dapat meningkatkan kuat lentur yang cukup besar.
Kendalanya ketika diaplikasikan di lapangan adalah kesulitan memindahkan dari tempat pengecoran ke lokasi struktur.
Salah satu metode untuk mengatasi ini digunakanlah pracetak segmental.
Balok beton dicetak dengan ukuran panjang yang pendek sehingga mudah dibawa ke lokasi proyek.
Penyambung antara segmen balok beton memegang peranan yang sangat penting.
Studi ini mencoba mengetahui pengaruh panjang sambungan pada jenis sambungan yang sudah tertentu.
Tiga buah benda uji yaitu balok beton tanpa sambungan, balok beton segmental dengan panjang sambungan 10 cm dan 15 digunakan dalam eksperimen.
Pengujian lentur dilakukan untuk mengetahui kapasitas dukung ketiga balok tersebut.
Hasilnya menunjukkan bahwa panjang sambungan berpengaruh terhadap kuat lentur balok beton segemental.
Namun kapasistas lentur balok beton segmental masih dibawah kapasitas lentur balok beton tanpa sambungan.

Related Results

ANALISIS KUAT TARIK BELAH BETON PADA STANDAR KUAT TEKAN K.250 DENGAN MENGGUNAKAN LIMBAH PECAHAN BETON SEBAGAI PENGGANTI AGREGAT KASAR
ANALISIS KUAT TARIK BELAH BETON PADA STANDAR KUAT TEKAN K.250 DENGAN MENGGUNAKAN LIMBAH PECAHAN BETON SEBAGAI PENGGANTI AGREGAT KASAR
Beton merupakan bahan konstruksi yang sangat penting dan paling dominan digunakan pada struktur bangunan. Beton sangat diminati karena bahan ini merupakan bahan konstruksi yang mem...
Studi Pemanfaatan Limbah Serat Gergaji Kayu dan Limbah Kertas Sebagai Campuran Beton Ringan
Studi Pemanfaatan Limbah Serat Gergaji Kayu dan Limbah Kertas Sebagai Campuran Beton Ringan
Limbah sering digunakan sebagai bahan untuk berbagai keperluan, termasuk dalam rekayasa bahan bangunan. Salah satu jenis limbah yang masih jarang diteliti sebagai campuran dalam pe...
ANALISIS PENURUNAN MUTU BETON STRUKTURAL AKIBAT PENGARUH AIR LAUT PADA MASA PEMELIHARAAN
ANALISIS PENURUNAN MUTU BETON STRUKTURAL AKIBAT PENGARUH AIR LAUT PADA MASA PEMELIHARAAN
Air laut memiliki kandungan garam yang tinggi yang dapat menggerogoti kekuatan dan keawetan beton. Hal ini disebabkan klorida yang terdapat pada air laut yang merupakan garam yang ...
Pengaruh Serat Baja Canai Dingin Bergelombang Terhadap Kekuatan Tekan Dan Lentur Beton
Pengaruh Serat Baja Canai Dingin Bergelombang Terhadap Kekuatan Tekan Dan Lentur Beton
Beton merupakan material konstruksi yang bersifat getas. Kombinasinya dengan baja pada material beton bertulang menjadikan material beton yang getas getas menjadi daktail. Pada bet...
Pemanfaatan Bahan PET Terhadap Daya Serap Air Pada Beton Pracetak Tipe U-Ditch
Pemanfaatan Bahan PET Terhadap Daya Serap Air Pada Beton Pracetak Tipe U-Ditch
Sampah merupakan salah satu pencemaran yang sangat umum ditemui pada saat ini. Hal ini disebabkan konsumsi plastik yang setiap tahunnya terus meningkat, salah satu jenis sampah pla...
Pengaruh Penggunaan Bonding Adhesive Terhadap Perilaku Lentur Balok Yang Disambung
Pengaruh Penggunaan Bonding Adhesive Terhadap Perilaku Lentur Balok Yang Disambung
Pada umumnya pengerjaan pengecoran banyak yang tidak sesuai atau berhenti karena adanya beberapa kendala dalam pelaksanaan pengerjaan beton. Hal ini menyebabkan adanya sambungan an...
LIMBAH KACA SEBAGAI PENGANTI SEBAGIAN AGREGAT HALUS UNTUK BETON RAMAH LINGKUNGAN
LIMBAH KACA SEBAGAI PENGANTI SEBAGIAN AGREGAT HALUS UNTUK BETON RAMAH LINGKUNGAN
Abstrak Limbah kaca menyebabkan masalah lingkungan yang kronis karena sangat sulit terurai di dalam tanah. Kaca banyak digunakan dalam kehidupan sehari-hari melalui produk manufakt...
ANALISIS SUBSTITUSI AGGREGAT KASAR MENGGUNAKAN LIMBAH KERAMIK TERHADAP KUAT TEKAN BETON
ANALISIS SUBSTITUSI AGGREGAT KASAR MENGGUNAKAN LIMBAH KERAMIK TERHADAP KUAT TEKAN BETON
Limbah keramik merupakan salah satu limbah yang dihasilkan dari perenovasian rumah maupun gedung di Kota Bukittinggi yang tidak dimanfaatkan. Pemanfaatan kembali limbah keramik men...

Back to Top