Syringe Pump With Nearly Empty Based Microcontroller Atmega328

View through CrossRef
Syringe Pump is a tool used to give liquid medicine or food liquid into the patient's body in a certain amount and within a certain period of time on a regular basis. The purpose of this study is to facilitate monitoring of fluid in the syringe so that the hose is not installed continuously when the liquid has run out. The circuit consists of an Atmega328 microcontroller, a motor driver, and an optocoupler sensor. Setting the syringe, volume and flowrate is done at the beginning. To insert liquid, the motor must be run by the way the settings have been done and press the start button. Tools need supply from PLN grids. Calibration is done using IDA 4 Plus. This tool is equipped with the addition of alarms nearly empty and the bolus button. From the measurements taken, at the 20 ml syringe the biggest error occurred at the 5 ml volume point of 0.4% and at the 50 ml syringe the biggest error occurred at the 5 ml volume point of 0.280%.This module can be used according to its function, because the% error is still below the ± 5% standard.
Title: Syringe Pump With Nearly Empty Based Microcontroller Atmega328
Description:
Syringe Pump is a tool used to give liquid medicine or food liquid into the patient's body in a certain amount and within a certain period of time on a regular basis.
The purpose of this study is to facilitate monitoring of fluid in the syringe so that the hose is not installed continuously when the liquid has run out.
The circuit consists of an Atmega328 microcontroller, a motor driver, and an optocoupler sensor.
Setting the syringe, volume and flowrate is done at the beginning.
To insert liquid, the motor must be run by the way the settings have been done and press the start button.
Tools need supply from PLN grids.
Calibration is done using IDA 4 Plus.
This tool is equipped with the addition of alarms nearly empty and the bolus button.
From the measurements taken, at the 20 ml syringe the biggest error occurred at the 5 ml volume point of 0.
4% and at the 50 ml syringe the biggest error occurred at the 5 ml volume point of 0.
280%.
This module can be used according to its function, because the% error is still below the ± 5% standard.

Related Results

Neonatal Syringe Pumps in Zambia: a Multisite Cross-Sectional Case Study
Neonatal Syringe Pumps in Zambia: a Multisite Cross-Sectional Case Study
Abstract Background: The global neonatal mortality rate is due to miss the third Sustainable Development Goal of 12 deaths per 100 live births by 2030. However, medical dev...
RANCANG BANGUN SYRINGE PUMP
RANCANG BANGUN SYRINGE PUMP
<p>  A syringe pump is a tool for inserting high-dose drug fluids given to patients. The accuracy and accuracy of the amount of fluid given to this device are quite high. The...
SISTEM KONTROL TINGKAT KEKERUHAN DAN PH PEMBERIAN PAKAN PADA AQUARIUM MENGGUNAKAN ATMEGA328 VIA IoT
SISTEM KONTROL TINGKAT KEKERUHAN DAN PH PEMBERIAN PAKAN PADA AQUARIUM MENGGUNAKAN ATMEGA328 VIA IoT
Rutinitas dalam pemberian pakan serta nilai parameter lingkungan akuarium perlu senantiasa diawasi dan dijaga pada rentang tertentu. Dengan memanfaatkan teknologi IoT peneliti ingi...
PROTOTYPE POMPA APUNG
PROTOTYPE POMPA APUNG
ABSTRACT Floating pump is a water pump than can flat and adapt to the level of water surface. This water pump is solution of the problem happens because of the significant increas...
Investigation of vortex in pump sump by V3V measurements
Investigation of vortex in pump sump by V3V measurements
Abstract The aims, scope and conclusions of the paper must be in a self-contained abstract of a single paragraph with 60-120 words. The abstract must be informative ...
A Multisite Inventory Study of Neonatal Syringe Pumps in Zambia
A Multisite Inventory Study of Neonatal Syringe Pumps in Zambia
Abstract Background: The global neonatal mortality rate is due to miss the third Sustainable Development Goal of 12 deaths per 100 live births by 2030. However, medical dev...
Modification of a Radial Pump Characteristics With Fluid Suction in the Vaneless Space
Modification of a Radial Pump Characteristics With Fluid Suction in the Vaneless Space
Abstract Flow instability is a common unsteady phenomenon in the field of turbomachinery that often causes large pressure fluctuations, performance penalties, and st...
Efficacy of air/water syringe tip sterilization
Efficacy of air/water syringe tip sterilization
AbstractBackgroundDental procedures involve contact between instruments and the patient's tissues, blood or saliva. This study evaluated the efficacy of the standardized sterilizat...

Back to Top