Syringe Pump Design
View through CrossRef
With the evolution of special care baby, intensive care, and coronary care units over the last decade, there has developed a need for greater accuracy in the control of increasingly potent infusions. The design of bedside syringe pump infusers that administer the contents of a syringe to a patient at a constant and predetermined rate will be considered in terms of their ergonomics, control, and safety. Syringe pump design has evolved over the past few years from simple mechanised forms of syringe driving to very sophisticated and precisely-controlled drive systems capable of high volumetric accuracy over a wide range of clinical conditions and sustained for long time periods. This has led to the development of new and critical forms of drug therapy. In addition, important progress has been made in the safety and reliability aspects of syringe pump design. Modern syringe pumps are expected to have fail-safe electronics to protect the patient in the event of a fault occurring. With the advent of modern microprocessor techniques, future syringe pumps can be expected to incorporate further sophisticated operational and safety enhancements, whilst remaining simple to operate. Typical safety enhancements could include the incorporation of a variable pressure sensor to protect against unwanted pressure build up in the IV line, the use of absolute linear encoding techniques for control and monitoring of the infusion, and the increasing use of self-tests and diagnostics to aid the user. Operational enhancements could include the ability to support pharmacokinetic techniques, as well as closed loop drug therapy and remote computer control. Whilst this suggests that infusion therapy might become too sophisticated for day to day use, comprehensive interactive instructions and diagnostic aids would contribute greatly to ease of use. Good user training will be of increasing importance to maximize the benefits of the advances in syringe pump design.
Title: Syringe Pump Design
Description:
With the evolution of special care baby, intensive care, and coronary care units over the last decade, there has developed a need for greater accuracy in the control of increasingly potent infusions.
The design of bedside syringe pump infusers that administer the contents of a syringe to a patient at a constant and predetermined rate will be considered in terms of their ergonomics, control, and safety.
Syringe pump design has evolved over the past few years from simple mechanised forms of syringe driving to very sophisticated and precisely-controlled drive systems capable of high volumetric accuracy over a wide range of clinical conditions and sustained for long time periods.
This has led to the development of new and critical forms of drug therapy.
In addition, important progress has been made in the safety and reliability aspects of syringe pump design.
Modern syringe pumps are expected to have fail-safe electronics to protect the patient in the event of a fault occurring.
With the advent of modern microprocessor techniques, future syringe pumps can be expected to incorporate further sophisticated operational and safety enhancements, whilst remaining simple to operate.
Typical safety enhancements could include the incorporation of a variable pressure sensor to protect against unwanted pressure build up in the IV line, the use of absolute linear encoding techniques for control and monitoring of the infusion, and the increasing use of self-tests and diagnostics to aid the user.
Operational enhancements could include the ability to support pharmacokinetic techniques, as well as closed loop drug therapy and remote computer control.
Whilst this suggests that infusion therapy might become too sophisticated for day to day use, comprehensive interactive instructions and diagnostic aids would contribute greatly to ease of use.
Good user training will be of increasing importance to maximize the benefits of the advances in syringe pump design.
Related Results
Neonatal Syringe Pumps in Zambia: a Multisite Cross-Sectional Case Study
Neonatal Syringe Pumps in Zambia: a Multisite Cross-Sectional Case Study
Abstract
Background: The global neonatal mortality rate is due to miss the third Sustainable Development Goal of 12 deaths per 100 live births by 2030. However, medical dev...
RANCANG BANGUN SYRINGE PUMP
RANCANG BANGUN SYRINGE PUMP
<p> A syringe pump is a tool for inserting high-dose drug fluids given to patients. The accuracy and accuracy of the amount of fluid given to this device are quite high. The...
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Abstract
New results for downhole beam or rod pumps, from fairly recent test data are in conflict with traditional relationships. Additional testing is in progres...
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Abstract
New results for downhole beam or rod pumps from fairly recent test data are in conflict with traditional relationships. Additional testing is in progress...
Pumping Unit Optimization
Pumping Unit Optimization
Abstract
In order to produce available fluids, pump jacks used at surface have been engineered to stroke as slow as 6 (six) strokes per minute (SPM) and as fast a...
New Solutions for Installation of Sucker Rod Pumps in Marginal Field
New Solutions for Installation of Sucker Rod Pumps in Marginal Field
Abstract
This paper uses case studies to showcase the techno-economic impact of insert anchor and portable foundation on the development of marginal fields. Case stu...
ANALISIS PEMELIHARAAN SYRINGE PUMP DI.LAB TERPADU UNIVERSITAS SARI MUTIARA INDONESIA
ANALISIS PEMELIHARAAN SYRINGE PUMP DI.LAB TERPADU UNIVERSITAS SARI MUTIARA INDONESIA
Medical devices are divices that are always in a ready to use condition and can function properly. This requires the Sari Mutiara University Integrated Laboratory to assist and med...