Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

RANCANG BANGUN SYRINGE PUMP

View through CrossRef
<p>  A syringe pump is a tool for inserting high-dose drug fluids given to patients. The accuracy and accuracy of the amount of fluid given to this device are quite high. The need for this tool in hospitals is very large, but in terms of the economy, the price of the equipment is still very expensive so it is not affordable for small hospitals. The purpose of making a syringe pump is to be able to meet the needs of the syringe pump in small hospitals so that it can save on budget expenses. Therefore a syringe pump is designed, designed using the Arduino Nano as a control system, display flow speed with 16x2 LCD, stepper motor as a syringe booster according to the regulated flow speed, and buzzer as an alarm when a blockage occurs and the syringe placement is incorrect. Flowrate parameters at a speed of 10 ml / hour, 20 ml / hour, 30 ml / hour, 40 ml / hour and 50 ml / hour.</p><p>Keywords: Syringe Pump, flowrate, stepper motor, Arduino Nano  </p>
Universitas Semarang
Title: RANCANG BANGUN SYRINGE PUMP
Description:
<p>  A syringe pump is a tool for inserting high-dose drug fluids given to patients.
The accuracy and accuracy of the amount of fluid given to this device are quite high.
The need for this tool in hospitals is very large, but in terms of the economy, the price of the equipment is still very expensive so it is not affordable for small hospitals.
The purpose of making a syringe pump is to be able to meet the needs of the syringe pump in small hospitals so that it can save on budget expenses.
Therefore a syringe pump is designed, designed using the Arduino Nano as a control system, display flow speed with 16x2 LCD, stepper motor as a syringe booster according to the regulated flow speed, and buzzer as an alarm when a blockage occurs and the syringe placement is incorrect.
Flowrate parameters at a speed of 10 ml / hour, 20 ml / hour, 30 ml / hour, 40 ml / hour and 50 ml / hour.
</p><p>Keywords: Syringe Pump, flowrate, stepper motor, Arduino Nano  </p>.

Related Results

Syringe Pump Design
Syringe Pump Design
With the evolution of special care baby, intensive care, and coronary care units over the last decade, there has developed a need for greater accuracy in the control of increasingl...
Neonatal Syringe Pumps in Zambia: a Multisite Cross-Sectional Case Study
Neonatal Syringe Pumps in Zambia: a Multisite Cross-Sectional Case Study
Abstract Background: The global neonatal mortality rate is due to miss the third Sustainable Development Goal of 12 deaths per 100 live births by 2030. However, medical dev...
Pumping Unit Optimization
Pumping Unit Optimization
Abstract In order to produce available fluids, pump jacks used at surface have been engineered to stroke as slow as 6 (six) strokes per minute (SPM) and as fast a...
New Solutions for Installation of Sucker Rod Pumps in Marginal Field
New Solutions for Installation of Sucker Rod Pumps in Marginal Field
Abstract This paper uses case studies to showcase the techno-economic impact of insert anchor and portable foundation on the development of marginal fields. Case stu...
ANALISIS PEMELIHARAAN SYRINGE PUMP DI.LAB TERPADU UNIVERSITAS SARI MUTIARA INDONESIA
ANALISIS PEMELIHARAAN SYRINGE PUMP DI.LAB TERPADU UNIVERSITAS SARI MUTIARA INDONESIA
Medical devices are divices that are always in a ready to use condition and can function properly. This requires the Sari Mutiara University Integrated Laboratory to assist and med...
PROTOTYPE POMPA APUNG
PROTOTYPE POMPA APUNG
ABSTRACT Floating pump is a water pump than can flat and adapt to the level of water surface. This water pump is solution of the problem happens because of the significant increas...
Investigation of vortex in pump sump by V3V measurements
Investigation of vortex in pump sump by V3V measurements
Abstract The aims, scope and conclusions of the paper must be in a self-contained abstract of a single paragraph with 60-120 words. The abstract must be informative ...
Effect of flushing technique on residual anaesthetic drug content in syringes
Effect of flushing technique on residual anaesthetic drug content in syringes
Abstract Introduction: The practice of reusing the same syringe to administer different medications during anaesthesia fo...