Moog Type Syringe Pump Repair Aitecs 2016 Advance d Sryinge Pump
View through CrossRef
Syringe Pump is one of the medical equipment that functions to insert medicinal liquid into patients for a certain period of time regularly. The Syringe Pump cannot function as it should. The damage that occurs to the Syringe Pump is caused by an optocoupler sensor error that causes the optocoupler sensor to not be able to push the syringe and the syringe size sensor that does not detect the size of the syringe due to ineffective use and causes the syringe size sensor to not be able to detect the size of the syringe. Therefore, improvements are needed to the sensor part of this tool so that it can detect the syringe as it functions. The repair of this Syringe Pump is carried out by measuring using a multimeter through a specified measurement point, after the results of the calculation are known, followed by the replacement of the optocoupler sensor, then gluing the broken syringe size sensor with glue, and finally testing the function of the tool with the Infusion Device Analyzer (IDA) tool so that the Syringe Pump is successfully repaired and usable. The value obtained from the measurement after making repairs to TP 1 (optocoupler sensor input) was obtained an error of 0% TP 2 (optocoupler sensor output) of 0.5%. TP 3 (syringe size sensor output) of 0%. The tool used for the function test was IDA (Infusion Device Analyzer) and obtained an average of 9.50 ml/h at the 10 ml/h setting. So it was concluded that the tool was functioning well because it was still within the tolerance limit of 10%. And the result of occlusion was 4.7 ml/h which was still at the tolerance limit.
Politeknik Pratama Purwokerto
Title: Moog Type Syringe Pump Repair Aitecs 2016 Advance d Sryinge Pump
Description:
Syringe Pump is one of the medical equipment that functions to insert medicinal liquid into patients for a certain period of time regularly.
The Syringe Pump cannot function as it should.
The damage that occurs to the Syringe Pump is caused by an optocoupler sensor error that causes the optocoupler sensor to not be able to push the syringe and the syringe size sensor that does not detect the size of the syringe due to ineffective use and causes the syringe size sensor to not be able to detect the size of the syringe.
Therefore, improvements are needed to the sensor part of this tool so that it can detect the syringe as it functions.
The repair of this Syringe Pump is carried out by measuring using a multimeter through a specified measurement point, after the results of the calculation are known, followed by the replacement of the optocoupler sensor, then gluing the broken syringe size sensor with glue, and finally testing the function of the tool with the Infusion Device Analyzer (IDA) tool so that the Syringe Pump is successfully repaired and usable.
The value obtained from the measurement after making repairs to TP 1 (optocoupler sensor input) was obtained an error of 0% TP 2 (optocoupler sensor output) of 0.
5%.
TP 3 (syringe size sensor output) of 0%.
The tool used for the function test was IDA (Infusion Device Analyzer) and obtained an average of 9.
50 ml/h at the 10 ml/h setting.
So it was concluded that the tool was functioning well because it was still within the tolerance limit of 10%.
And the result of occlusion was 4.
7 ml/h which was still at the tolerance limit.
Related Results
Neonatal Syringe Pumps in Zambia: a Multisite Cross-Sectional Case Study
Neonatal Syringe Pumps in Zambia: a Multisite Cross-Sectional Case Study
Abstract
Background: The global neonatal mortality rate is due to miss the third Sustainable Development Goal of 12 deaths per 100 live births by 2030. However, medical dev...
Syringe Pump Design
Syringe Pump Design
With the evolution of special care baby, intensive care, and coronary care units over the last decade, there has developed a need for greater accuracy in the control of increasingl...
Concomitant Medial Meniscal Root Repair with Extrusion Repair (Centralization Technique)
Concomitant Medial Meniscal Root Repair with Extrusion Repair (Centralization Technique)
Background:
Meniscal extrusion is a phenomenon in which a degenerative posterior horn tear, radial tear, or root tear results in displacement of the body of the meniscu...
RANCANG BANGUN SYRINGE PUMP
RANCANG BANGUN SYRINGE PUMP
<p> A syringe pump is a tool for inserting high-dose drug fluids given to patients. The accuracy and accuracy of the amount of fluid given to this device are quite high. The...
I Bought Bob Moog
I Bought Bob Moog
Abstract
The Moog mystique was untouchable, but the synthesizer industry had evolved into a dog-eat-dog business. CBS had dropped the Buchla, and ARP was gaining on ...
ANALISIS PEMELIHARAAN SYRINGE PUMP DI.LAB TERPADU UNIVERSITAS SARI MUTIARA INDONESIA
ANALISIS PEMELIHARAAN SYRINGE PUMP DI.LAB TERPADU UNIVERSITAS SARI MUTIARA INDONESIA
Medical devices are divices that are always in a ready to use condition and can function properly. This requires the Sari Mutiara University Integrated Laboratory to assist and med...
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Abstract
New results for downhole beam or rod pumps, from fairly recent test data are in conflict with traditional relationships. Additional testing is in progres...
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Abstract
New results for downhole beam or rod pumps from fairly recent test data are in conflict with traditional relationships. Additional testing is in progress...