Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Study on custom centrifugal pump performance in supplying food based high viscos liquid

View through CrossRef
Viscosity is one of the factors affecting the performance of the centrifugal pump. A centrifugal pump is a device that used driven motor called impeller to move fluid by rotational energy. This thesis is about the analysis of the performance of the centrifugal pump when transferring viscous liquids. For this project, the objective is to design and fabricate a device that can pump liquid with various viscosity using centrifugal pump. The liquids used in the experiment are comprised of a mixture of detergent and water with different ratio to alter the viscosity. The viscosity is being identified by the usage of Zahn Cup Method with the temperature kept constant at 26 °C throughout the experiment. The performance of the centrifugal pump is being investigated by four parameters which is the flowrate, Total Dynamic Head (TDH), power and efficiency. The performance of the centrifugal pump can be accessed by altering the pump shaft speed in order to get various reading for the flow rate. In order to alter the pump shaft speed, the usage of motor with Variable Frequency Drive (VFD) is implemented. The values for the flowrate and pump shaft power are measured by flowmeter and Variable Frequency Drive (VFD). The Total Dynamic Head (TDH), hydraulic power and pump efficiency is calculated based on the reading of the flowmeter and pump shaft power displayed at Variable Frequency Drive (VFD). At the end of this project, the pump performance while pumping different viscous liquids at different flowrates is being identified.
Title: Study on custom centrifugal pump performance in supplying food based high viscos liquid
Description:
Viscosity is one of the factors affecting the performance of the centrifugal pump.
A centrifugal pump is a device that used driven motor called impeller to move fluid by rotational energy.
This thesis is about the analysis of the performance of the centrifugal pump when transferring viscous liquids.
For this project, the objective is to design and fabricate a device that can pump liquid with various viscosity using centrifugal pump.
The liquids used in the experiment are comprised of a mixture of detergent and water with different ratio to alter the viscosity.
The viscosity is being identified by the usage of Zahn Cup Method with the temperature kept constant at 26 °C throughout the experiment.
The performance of the centrifugal pump is being investigated by four parameters which is the flowrate, Total Dynamic Head (TDH), power and efficiency.
The performance of the centrifugal pump can be accessed by altering the pump shaft speed in order to get various reading for the flow rate.
In order to alter the pump shaft speed, the usage of motor with Variable Frequency Drive (VFD) is implemented.
The values for the flowrate and pump shaft power are measured by flowmeter and Variable Frequency Drive (VFD).
The Total Dynamic Head (TDH), hydraulic power and pump efficiency is calculated based on the reading of the flowmeter and pump shaft power displayed at Variable Frequency Drive (VFD).
At the end of this project, the pump performance while pumping different viscous liquids at different flowrates is being identified.

Related Results

Integrated switchable ventricular assist devices for pediatric patients
Integrated switchable ventricular assist devices for pediatric patients
Thousands of children are born each year with significant cardiac defects that result in the development of heart disease and ultimately premature congestive heart failure (CHF). I...
CONVERSION OF CHARACTERISTICS OF CENTRIFUGAL PUMPS TO VISCOUS LIQUIDS
CONVERSION OF CHARACTERISTICS OF CENTRIFUGAL PUMPS TO VISCOUS LIQUIDS
The urgency of the work is due to the large use of modern industry centrifugal pumps for pumping viscous liquids. In the energy sector, this is the use of fuel oil and thermal powe...
Cash‐based approaches in humanitarian emergencies: a systematic review
Cash‐based approaches in humanitarian emergencies: a systematic review
This Campbell systematic review examines the effectiveness, efficiency and implementation of cash transfers in humanitarian settings. The review summarises evidence from five studi...
ANALISIS PERFORMANCE POMPA FEED SENTRIFUGAL
ANALISIS PERFORMANCE POMPA FEED SENTRIFUGAL
To support the optimization of operations at a refinery, a tool is urgently needed that can help process crude oil into a product. The centrifugal feed pump P-100/4 is a pump that ...
Series multi-blood pump with dual activation for pediatric patients with heart failure
Series multi-blood pump with dual activation for pediatric patients with heart failure
Pediatric heart failure (HF), arising from both congenital and acquired disorders, is a serious pathology that affects thousands of children each year. Severe cases of pediatric HF...
Gaseous cavitation characteristics of high-speed hydraulic electric motor-pump based on centrifugal pressurization: A numerical study
Gaseous cavitation characteristics of high-speed hydraulic electric motor-pump based on centrifugal pressurization: A numerical study
Hydraulic electric motor-pump is an integrated hydraulic power unit, raising rotational speed will further increase its power density. However, gaseous cavitation at high speed is ...
NUMERICAL CALCULATIONS OF THE IMPELLER OF A CENTRIFUGAL PUMP USED IN THE OIL AND GAS INDUSTRY
NUMERICAL CALCULATIONS OF THE IMPELLER OF A CENTRIFUGAL PUMP USED IN THE OIL AND GAS INDUSTRY
Pumps are used to transport liquid products within technological installations inside and outside any petrochemical industry enterprise. Pumps are also used in drilling oil and gas...
Development of a Compact, Sealless, Tripod Supported, Magnetically Driven Centrifugal Blood Pump
Development of a Compact, Sealless, Tripod Supported, Magnetically Driven Centrifugal Blood Pump
Abstract: In this study, a tripod supported sealless centrifugal blood pump was designed and fabricated for implantable application using a specially designed DC brushless motor. T...

Back to Top