Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Early experience of placing image-guided minimally invasive pedicle screws without K-wires or bone-anchored trackers

View through CrossRef
OBJECTIVEImage guidance for spine surgery has been reported to improve the accuracy of pedicle screw placement and reduce revision rates and radiation exposure. Current navigation and robot-assisted techniques for percutaneous screws rely on bone-anchored trackers and Kirchner wires (K-wires). There is a paucity of published data regarding the placement of image-guided percutaneous screws without K-wires. A new skin-adhesive stereotactic patient tracker (SpineMask) eliminates both an invasive bone-anchored tracker and K-wires for pedicle screw placement. This study reports the authors’ early experience with the use of SpineMask for “K-wireless” placement of minimally invasive pedicle screws and makes recommendations for its potential applications in lumbar fusion.METHODSForty-five consecutive patients (involving 204 screws inserted) underwent K-wireless lumbar pedicle screw fixation with SpineMask and intraoperative neuromonitoring. Screws were inserted by percutaneous stab or Wiltse incisions. If required, decompression with or without interbody fusion was performed using mini-open midline incisions. Multimodality intraoperative neuromonitoring assessing motor and sensory responses with triggered electromyography (tEMG) was performed. Computed tomography scans were obtained 2 days postoperatively to assess screw placement and any cortical breaches. A breach was defined as any violation of a pedicle screw involving the cortical bone of the pedicle.RESULTSFourteen screws (7%) required intraoperative revision. Screws were removed and repositioned due to a tEMG response < 13 mA, tactile feedback, and 3D fluoroscopic assessment. All screws were revised using the SpineMask with the same screw placement technique. The highest proportion of revisions occurred with Wiltse incisions (4/12, 33%) as this caused the greatest degree of SpineMask deformation, followed by a mini midline incision (3/26, 12%). Percutaneous screws via a single stab incision resulted in the fewest revisions (7/166, 4%). Postoperative CT demonstrated 7 pedicle screw breaches (3%; 5 lateral, 1 medial, 1 superior), all with percutaneous stab incisions (7/166, 4%). The radiological accuracy of the SpineMask tracker was 97% (197/204 screws). No patients suffered neural injury or required postoperative screw revision.CONCLUSIONSThe noninvasive cutaneous SpineMask tracker with 3D image guidance and tEMG monitoring provided high accuracy (97%) for percutaneous pedicle screw placement via stab incisions without K-wires.
Journal of Neurosurgery Publishing Group (JNSPG)
Title: Early experience of placing image-guided minimally invasive pedicle screws without K-wires or bone-anchored trackers
Description:
OBJECTIVEImage guidance for spine surgery has been reported to improve the accuracy of pedicle screw placement and reduce revision rates and radiation exposure.
Current navigation and robot-assisted techniques for percutaneous screws rely on bone-anchored trackers and Kirchner wires (K-wires).
There is a paucity of published data regarding the placement of image-guided percutaneous screws without K-wires.
A new skin-adhesive stereotactic patient tracker (SpineMask) eliminates both an invasive bone-anchored tracker and K-wires for pedicle screw placement.
This study reports the authors’ early experience with the use of SpineMask for “K-wireless” placement of minimally invasive pedicle screws and makes recommendations for its potential applications in lumbar fusion.
METHODSForty-five consecutive patients (involving 204 screws inserted) underwent K-wireless lumbar pedicle screw fixation with SpineMask and intraoperative neuromonitoring.
Screws were inserted by percutaneous stab or Wiltse incisions.
If required, decompression with or without interbody fusion was performed using mini-open midline incisions.
Multimodality intraoperative neuromonitoring assessing motor and sensory responses with triggered electromyography (tEMG) was performed.
Computed tomography scans were obtained 2 days postoperatively to assess screw placement and any cortical breaches.
A breach was defined as any violation of a pedicle screw involving the cortical bone of the pedicle.
RESULTSFourteen screws (7%) required intraoperative revision.
Screws were removed and repositioned due to a tEMG response < 13 mA, tactile feedback, and 3D fluoroscopic assessment.
All screws were revised using the SpineMask with the same screw placement technique.
The highest proportion of revisions occurred with Wiltse incisions (4/12, 33%) as this caused the greatest degree of SpineMask deformation, followed by a mini midline incision (3/26, 12%).
Percutaneous screws via a single stab incision resulted in the fewest revisions (7/166, 4%).
Postoperative CT demonstrated 7 pedicle screw breaches (3%; 5 lateral, 1 medial, 1 superior), all with percutaneous stab incisions (7/166, 4%).
The radiological accuracy of the SpineMask tracker was 97% (197/204 screws).
No patients suffered neural injury or required postoperative screw revision.
CONCLUSIONSThe noninvasive cutaneous SpineMask tracker with 3D image guidance and tEMG monitoring provided high accuracy (97%) for percutaneous pedicle screw placement via stab incisions without K-wires.

Related Results

Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
There are no published biomechanical studies evaluating the effect of stabilization techniques on the stability of the 3D printed models of the canine lumbosacral junction. The p...
Effect of Pedicle Fill on Axial Pullout Strength in Spinal Fixation After Rod Reduction
Effect of Pedicle Fill on Axial Pullout Strength in Spinal Fixation After Rod Reduction
Rod reduction to pedicle screws is used for a variety of spinal fixation procedures; however, it can alter the integrity of the screw-bone interface. The authors investigated the e...
Bone Allograft Pedicle Screw Augmentation
Bone Allograft Pedicle Screw Augmentation
Study Design: We performed a comprehensive cadaveric biomechanical study to compare the fixation strength of primary screws, screws augmented with bone allograft, and s...
Pull-out strength of cemented solidversusfenestrated pedicle screws in osteoporotic vertebrae
Pull-out strength of cemented solidversusfenestrated pedicle screws in osteoporotic vertebrae
ObjectivesCement augmentation of pedicle screws could be used to improve screw stability, especially in osteoporotic vertebrae. However, little is known concerning the influence of...
Pedicle Screw Bond Strength and Resistance Characteristics With Various Mineral Quality
Pedicle Screw Bond Strength and Resistance Characteristics With Various Mineral Quality
Abnormal quality and composition of bone mineral bonds in the spine are found in many patients with cases of idiopathic scoliosis. The data shows that poor bone quality promotes th...
Osseointegration Potential of Boron-Coated Titanium Alloy Pedicle Screw in Rabbit Spine Model
Osseointegration Potential of Boron-Coated Titanium Alloy Pedicle Screw in Rabbit Spine Model
Abstract Study Design: Prospective, randomized controlled trial Objective To enhance stem cell conversion and osseointegration using boron-coated screws and leveraging bo...
Poster 107: The Use of Coacervate Sustained Release System to Identify the Most Potent BMP for Bone Regeneration
Poster 107: The Use of Coacervate Sustained Release System to Identify the Most Potent BMP for Bone Regeneration
Objectives: Bone morphogenetic proteins (BMPs) belong to the transforming growth factor superfamily that were first discovered by Marshall Urist. There are 14 B...

Back to Top