Javascript must be enabled to continue!
Pedicle Screw Bond Strength and Resistance Characteristics With Various Mineral Quality
View through CrossRef
Abnormal quality and composition of bone mineral bonds in the spine are found in many patients with cases of idiopathic scoliosis. The data shows that poor bone quality promotes thoracic spine degenerative disc swelling and physiological anomalies. Implants in the form of pedicle screws, rods, and connectors are one of the measures for scoliosis correction. When the pedicle screws are taken out after some use poor bone quality remains. In this study, fixation strength analysis will be carried out through tensile testing of bone joints and pedicle screws with variations in bone quality. Two specimen materials were used for approach analysis: polylactic acid (PLA) and bovine backbone. Pedicle screws are classified into three types: cylindrical, conical with a single thread, and double cylindrical screws. Tensile testing revealed that PLA specimens with pedicle screw variants provided the maximum force of 7.4 N and 8.31 N with double screw cylindrical implants at PLA 70:30 and PLA 40:60. A comparison of PLA specimens with a series of cylindrical screws to double-screw cylindrical screws yielded a displacement increase of 79.6%, whereas conical screws yielded a displacement increase of 222.3%. Fixation with double-screw cylindrical screws greatly increases tensile strength. However, the conical pedicle screw model with connecting rods gives greater fixation strength.
Association for Information Communication Technology Education and Science (UIKTEN)
Title: Pedicle Screw Bond Strength and Resistance Characteristics With Various Mineral Quality
Description:
Abnormal quality and composition of bone mineral bonds in the spine are found in many patients with cases of idiopathic scoliosis.
The data shows that poor bone quality promotes thoracic spine degenerative disc swelling and physiological anomalies.
Implants in the form of pedicle screws, rods, and connectors are one of the measures for scoliosis correction.
When the pedicle screws are taken out after some use poor bone quality remains.
In this study, fixation strength analysis will be carried out through tensile testing of bone joints and pedicle screws with variations in bone quality.
Two specimen materials were used for approach analysis: polylactic acid (PLA) and bovine backbone.
Pedicle screws are classified into three types: cylindrical, conical with a single thread, and double cylindrical screws.
Tensile testing revealed that PLA specimens with pedicle screw variants provided the maximum force of 7.
4 N and 8.
31 N with double screw cylindrical implants at PLA 70:30 and PLA 40:60.
A comparison of PLA specimens with a series of cylindrical screws to double-screw cylindrical screws yielded a displacement increase of 79.
6%, whereas conical screws yielded a displacement increase of 222.
3%.
Fixation with double-screw cylindrical screws greatly increases tensile strength.
However, the conical pedicle screw model with connecting rods gives greater fixation strength.
Related Results
The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert
The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert
When used in combination with decompression, spinal fusion is a successful procedure for treating patients with spinal stenosis and degenerative spondylolisthesis. While a number o...
Effect of Pedicle Fill on Axial Pullout Strength in Spinal Fixation After Rod Reduction
Effect of Pedicle Fill on Axial Pullout Strength in Spinal Fixation After Rod Reduction
Rod reduction to pedicle screws is used for a variety of spinal fixation procedures; however, it can alter the integrity of the screw-bone interface. The authors investigated the e...
Bone Allograft Pedicle Screw Augmentation
Bone Allograft Pedicle Screw Augmentation
Study Design:
We performed a comprehensive cadaveric biomechanical study to compare the fixation strength of primary screws, screws augmented with bone allograft, and s...
The Place of 3D Printing Preoperative Planning in Upper Thoracic Fractures
The Place of 3D Printing Preoperative Planning in Upper Thoracic Fractures
Abstract
Background: This study aims to compare the clinical results of patients with upper thoracic vertebral fractures treated with pedicle screw and posterior spinal fus...
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
There are no published biomechanical studies evaluating the effect of stabilization techniques on the stability of the 3D printed models of the canine lumbosacral junction. The p...
Minimizing Pedicle Screw Pullout Risks
Minimizing Pedicle Screw Pullout Risks
Study Design:
Detailed biomechanical analysis of the anchorage performance provided by different pedicle screw designs and placement strategies under pullout loading.
...
Comparison of posterior open screw fixation with percutaneous fixation among traumatic thoracolumbar fracture patients.
Comparison of posterior open screw fixation with percutaneous fixation among traumatic thoracolumbar fracture patients.
Objectives: To compare outcome and adverse events of open posterior pedicle screw fixation with percutaneous posterior pedicle screw fixation among patients suffering traumatic tho...
Biomechanical analysis of pedicle screw density in spinal instrumentation for scoliosis treatment: first results
Biomechanical analysis of pedicle screw density in spinal instrumentation for scoliosis treatment: first results
Clinical studies reveal remarkable variation in screw patterns, or screw density in spinal instrumentation. Screw density may have a great impact on blood loss, operative time, rad...