Javascript must be enabled to continue!
The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert
View through CrossRef
When used in combination with decompression, spinal fusion is a successful procedure for treating patients with spinal stenosis and degenerative spondylolisthesis. While a number of auxiliary devices have been proposed to enhance the fixation of the screw within the pedicle and vertebral body, there is conflicting information regarding the efficacy of their use. Therefore, the aim of this study was to determine the ability of a novel expandable pedicle screw to improve the fixation of the pedicle screw within the pedicle and vertebral body. A three-dimensional (3D) printed, screw sleeve was designed that expanded within the pedicle and vertebral body when a standard pedicle screw was inserted into it. The left and right pedicle of ten (N = 10) cadaveric lumbar spine specimens (L3–L5) were randomly assigned to be instrumented with either a pedicle screw and the sleeve or a pedicle screw only. Following instrumentation, the screws were exposed to tensile load at 5 mm/min until failure. The failure force, failure deformation, and area under the force–deformation curve were determined and compared between screw conditions. There were no significant differences between the screws and sleeve, and the screw only conditions for the failure force (p = 0.24), failure displacement (p = 0.10), and area under the curve (p = 0.38). While the novel screw sleeve presented here performed as well as a screw without a sleeve, it was better than other screw augmentation devices reported previously. In addition, it is likely that this device would prove useful as an enhancement to revision.
Title: The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert
Description:
When used in combination with decompression, spinal fusion is a successful procedure for treating patients with spinal stenosis and degenerative spondylolisthesis.
While a number of auxiliary devices have been proposed to enhance the fixation of the screw within the pedicle and vertebral body, there is conflicting information regarding the efficacy of their use.
Therefore, the aim of this study was to determine the ability of a novel expandable pedicle screw to improve the fixation of the pedicle screw within the pedicle and vertebral body.
A three-dimensional (3D) printed, screw sleeve was designed that expanded within the pedicle and vertebral body when a standard pedicle screw was inserted into it.
The left and right pedicle of ten (N = 10) cadaveric lumbar spine specimens (L3–L5) were randomly assigned to be instrumented with either a pedicle screw and the sleeve or a pedicle screw only.
Following instrumentation, the screws were exposed to tensile load at 5 mm/min until failure.
The failure force, failure deformation, and area under the force–deformation curve were determined and compared between screw conditions.
There were no significant differences between the screws and sleeve, and the screw only conditions for the failure force (p = 0.
24), failure displacement (p = 0.
10), and area under the curve (p = 0.
38).
While the novel screw sleeve presented here performed as well as a screw without a sleeve, it was better than other screw augmentation devices reported previously.
In addition, it is likely that this device would prove useful as an enhancement to revision.
Related Results
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
There are no published biomechanical studies evaluating the effect of stabilization techniques on the stability of the 3D printed models of the canine lumbosacral junction. The p...
Determination of effective riser sleeve thermophysical properties for simulation and analysis of riser sleeve performance
Determination of effective riser sleeve thermophysical properties for simulation and analysis of riser sleeve performance
<p>Riser sleeve thermophysical properties for simulation are developed using an inverse modeling technique. Casting experiments using riser sleeves are performed in order to ...
Technology of preparation of sleeve ends before pilgrims rolling
Technology of preparation of sleeve ends before pilgrims rolling
The paper considers the issues of improvement of hot pilgrim rolling of pipes by means of preparation of front and rear ends of sleeves. The presence of a gap between the sleeve an...
Minimizing Pedicle Screw Pullout Risks
Minimizing Pedicle Screw Pullout Risks
Study Design:
Detailed biomechanical analysis of the anchorage performance provided by different pedicle screw designs and placement strategies under pullout loading.
...
Comparison of posterior open screw fixation with percutaneous fixation among traumatic thoracolumbar fracture patients.
Comparison of posterior open screw fixation with percutaneous fixation among traumatic thoracolumbar fracture patients.
Objectives: To compare outcome and adverse events of open posterior pedicle screw fixation with percutaneous posterior pedicle screw fixation among patients suffering traumatic tho...
Biomechanical analysis of pedicle screw density in spinal instrumentation for scoliosis treatment: first results
Biomechanical analysis of pedicle screw density in spinal instrumentation for scoliosis treatment: first results
Clinical studies reveal remarkable variation in screw patterns, or screw density in spinal instrumentation. Screw density may have a great impact on blood loss, operative time, rad...
Study on Positioning Accuracy of Aerostatic Lead Screw
Study on Positioning Accuracy of Aerostatic Lead Screw
The aerostatic lead screw is a non-contact type lead screw in which the contact surface of a male screw and a female screw is supported by a pressurized air film. It is characteriz...
Patient-specific template-guided versus standard freehand lumbar pedicle screw implantation: a randomized controlled trial
Patient-specific template-guided versus standard freehand lumbar pedicle screw implantation: a randomized controlled trial
OBJECTIVE
Patient-specific template-guided (TG) pedicle screw placement currently achieves the highest reported accuracy in cadaveric and early clinical studies, with reports of re...

