Javascript must be enabled to continue!
Minimizing Pedicle Screw Pullout Risks
View through CrossRef
Study Design:
Detailed biomechanical analysis of the anchorage performance provided by different pedicle screw designs and placement strategies under pullout loading.
Objective:
To biomechanically characterize the specific effects of surgeon-specific pedicle screw design parameters on anchorage performance using a finite element model.
Summary of Background Data:
Pedicle screw fixation is commonly used in the treatment of spinal pathologies. However, there is little consensus on the selection of an optimal screw type, size, and insertion trajectory depending on vertebra dimension and shape.
Methods:
Different screw diameters and lengths, threads, and insertion trajectories were computationally tested using a design of experiment approach. A detailed finite element model of an L3 vertebra was created including elastoplastic bone properties and contact interactions with the screws. Loads and boundary conditions were applied to the screws to simulate axial pullout tests. Force-displacement responses and internal stresses were analyzed to determine the specific effects of each parameter.
Results:
The design of experiment analysis revealed significant effects (P<0.01) for all tested principal parameters along with the interactions between diameter and trajectory. Screw diameter had the greatest impact on anchorage performance. The best insertion trajectory to resist pullout involved placing the screw threads closer to the pedicle walls using the straightforward insertion technique, which showed the importance of the cortical layer grip. The simulated cylindrical single-lead thread screws presented better biomechanical anchorage than the conical dual-lead thread screws in axial loading conditions.
Conclusions:
The model made it possible to quantitatively measure the effects of both screw design characteristics and surgical choices, enabling to recommend strategies to improve single pedicle screw performance under axial loading.
Ovid Technologies (Wolters Kluwer Health)
Title: Minimizing Pedicle Screw Pullout Risks
Description:
Study Design:
Detailed biomechanical analysis of the anchorage performance provided by different pedicle screw designs and placement strategies under pullout loading.
Objective:
To biomechanically characterize the specific effects of surgeon-specific pedicle screw design parameters on anchorage performance using a finite element model.
Summary of Background Data:
Pedicle screw fixation is commonly used in the treatment of spinal pathologies.
However, there is little consensus on the selection of an optimal screw type, size, and insertion trajectory depending on vertebra dimension and shape.
Methods:
Different screw diameters and lengths, threads, and insertion trajectories were computationally tested using a design of experiment approach.
A detailed finite element model of an L3 vertebra was created including elastoplastic bone properties and contact interactions with the screws.
Loads and boundary conditions were applied to the screws to simulate axial pullout tests.
Force-displacement responses and internal stresses were analyzed to determine the specific effects of each parameter.
Results:
The design of experiment analysis revealed significant effects (P<0.
01) for all tested principal parameters along with the interactions between diameter and trajectory.
Screw diameter had the greatest impact on anchorage performance.
The best insertion trajectory to resist pullout involved placing the screw threads closer to the pedicle walls using the straightforward insertion technique, which showed the importance of the cortical layer grip.
The simulated cylindrical single-lead thread screws presented better biomechanical anchorage than the conical dual-lead thread screws in axial loading conditions.
Conclusions:
The model made it possible to quantitatively measure the effects of both screw design characteristics and surgical choices, enabling to recommend strategies to improve single pedicle screw performance under axial loading.
Related Results
The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert
The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert
When used in combination with decompression, spinal fusion is a successful procedure for treating patients with spinal stenosis and degenerative spondylolisthesis. While a number o...
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
There are no published biomechanical studies evaluating the effect of stabilization techniques on the stability of the 3D printed models of the canine lumbosacral junction. The p...
The anti-loosening characteristics of cortical bone trajectory screws and conventional pedicle screws under different bone quality conditions: a comparative study
The anti-loosening characteristics of cortical bone trajectory screws and conventional pedicle screws under different bone quality conditions: a comparative study
Abstract
Purpose: We aimed to compare the characteristics of anti-loosening and the pullout force between cortical bone trajectory (CBT) and conventional trajectory (CT) sc...
Comparison of posterior open screw fixation with percutaneous fixation among traumatic thoracolumbar fracture patients.
Comparison of posterior open screw fixation with percutaneous fixation among traumatic thoracolumbar fracture patients.
Objectives: To compare outcome and adverse events of open posterior pedicle screw fixation with percutaneous posterior pedicle screw fixation among patients suffering traumatic tho...
Biomechanical analysis of pedicle screw density in spinal instrumentation for scoliosis treatment: first results
Biomechanical analysis of pedicle screw density in spinal instrumentation for scoliosis treatment: first results
Clinical studies reveal remarkable variation in screw patterns, or screw density in spinal instrumentation. Screw density may have a great impact on blood loss, operative time, rad...
Comparison of Pedicle Screw Loosening Mechanisms and the Effect on Fixation Strength
Comparison of Pedicle Screw Loosening Mechanisms and the Effect on Fixation Strength
Screw loosening is a common complication in spinal fixation using pedicle screws which may lead to loss of correction and revision surgery. The mechanisms of pedicle screw loosenin...
Study on Positioning Accuracy of Aerostatic Lead Screw
Study on Positioning Accuracy of Aerostatic Lead Screw
The aerostatic lead screw is a non-contact type lead screw in which the contact surface of a male screw and a female screw is supported by a pressurized air film. It is characteriz...
Patient-specific template-guided versus standard freehand lumbar pedicle screw implantation: a randomized controlled trial
Patient-specific template-guided versus standard freehand lumbar pedicle screw implantation: a randomized controlled trial
OBJECTIVE
Patient-specific template-guided (TG) pedicle screw placement currently achieves the highest reported accuracy in cadaveric and early clinical studies, with reports of re...

