SU‐F‐T‐474: Evaluation of Dose Perturbation, Temperature and Sensitivity Variation With Accumulated Dose of MOSFET Detector

View through CrossRef
Purpose:The use of mega voltage gamma and x‐ray sources with their skin sparring qualities in radiation therapy has been a boon in relieving patient discomfort and allowing high tumor doses to be given with fewer restrictions due to radiation effects in the skin. However, high doses given to deep tumors may require careful consideration of dose distribution in the buildup region in order to avoid irreparable damage to the skin.Methods:To measure the perturbation of MOSFET detector in Co60,6MV and 15MV the detector was placed on the surface of the phantom covered with the brass build up cap. To measure the effect of temperature the MOSFET detector was kept on the surface of hot water polythene container and the radiation was delivere. In order to measure the sensitivity variation with accumulated dose Measurements were taken by delivering the dose of 200 cGy to MOSFET until the MOSFET absorbed dose comes to 20,000 cGyResults:the Measurement was performed by positioning the bare MOSFET and MOSFET with brass build up cap on the top surface of the solid water phantom for various field sizes in order to find whether there is any attenuation caused in the dose distribution. The response of MOSFET was monitored for temperature ranging from 42 degree C to 22 degree C. The integrated dose dependence of MOSFET dosimeter sensitivity over different energy is not well characterized. This work investigates the dual‐bias MOSFET dosimeter sensitivity response to 6 MV and 15 MV beams.Conclusion:From this study it is observed that unlike diode, bare MOSFET does not perturb the radiation field.. It is observed that the build‐up influences the temperature dependency of MOSFET and causes some uncertainty in the readings. In the case of sensitivity variation with accumulated dose MOSFET showed higher sensitivity with dose accumulation for both the energies.
Title: SU‐F‐T‐474: Evaluation of Dose Perturbation, Temperature and Sensitivity Variation With Accumulated Dose of MOSFET Detector
Description:
Purpose:The use of mega voltage gamma and x‐ray sources with their skin sparring qualities in radiation therapy has been a boon in relieving patient discomfort and allowing high tumor doses to be given with fewer restrictions due to radiation effects in the skin.
However, high doses given to deep tumors may require careful consideration of dose distribution in the buildup region in order to avoid irreparable damage to the skin.
Methods:To measure the perturbation of MOSFET detector in Co60,6MV and 15MV the detector was placed on the surface of the phantom covered with the brass build up cap.
To measure the effect of temperature the MOSFET detector was kept on the surface of hot water polythene container and the radiation was delivere.
In order to measure the sensitivity variation with accumulated dose Measurements were taken by delivering the dose of 200 cGy to MOSFET until the MOSFET absorbed dose comes to 20,000 cGyResults:the Measurement was performed by positioning the bare MOSFET and MOSFET with brass build up cap on the top surface of the solid water phantom for various field sizes in order to find whether there is any attenuation caused in the dose distribution.
The response of MOSFET was monitored for temperature ranging from 42 degree C to 22 degree C.
The integrated dose dependence of MOSFET dosimeter sensitivity over different energy is not well characterized.
This work investigates the dual‐bias MOSFET dosimeter sensitivity response to 6 MV and 15 MV beams.
Conclusion:From this study it is observed that unlike diode, bare MOSFET does not perturb the radiation field.
It is observed that the build‐up influences the temperature dependency of MOSFET and causes some uncertainty in the readings.
In the case of sensitivity variation with accumulated dose MOSFET showed higher sensitivity with dose accumulation for both the energies.

Related Results

SU‐E‐T‐198: Evaluation of Dosimetric Characteristics of MOSFET Dosimeter for the Quality Assurance of Photon and Electron Beams
SU‐E‐T‐198: Evaluation of Dosimetric Characteristics of MOSFET Dosimeter for the Quality Assurance of Photon and Electron Beams
Purpose: To study the basic dosimetric characteristics of MOSFET dosimeter for its suitability on constructing the quality assurance phantom. Methods: For all the measurements, the...
Characterization of a novel HgCdTe focal plane array for ground and space astronomy through innovative infrared setups
Characterization of a novel HgCdTe focal plane array for ground and space astronomy through innovative infrared setups
(English) Nowadays, mercury-cadmium-telluride (MCT) short-wave infrared (SWIR) detectors are widely used in cutting-edge space missions and ground-based telescopes. They take adva...
A method to generate adversarial examples based on color variety of adjacent pixels
A method to generate adversarial examples based on color variety of adjacent pixels
Deep neural networks have improved the performance of large-scale learning tasks such as image recognition and speech recognition. However, neural networks also have vulnerabilitie...
Conceptual design report of the MPD Cosmic Ray Detector (MCORD)
Conceptual design report of the MPD Cosmic Ray Detector (MCORD)
Abstract This report presents a concept of constructing a detector dedicated for detection of muons observed during measurements carried out at the MPD (Multi-Pu...
DEVICE AND CIRCUIT LEVEL SIMULATION STUDY OF NOR GATE LOGIC FAMILIES DESIGNED USING NANO-MOSFETs
DEVICE AND CIRCUIT LEVEL SIMULATION STUDY OF NOR GATE LOGIC FAMILIES DESIGNED USING NANO-MOSFETs
The investigation of silicon-based nano-MOSFETs logic circuits is helpful to gain more comprehensive knowledge about nanoscale transistors. Therefore, a simulation study has been p...
Study of Strained-SiGe Channel P-MOSFET Using Silvaco TCAD: Impact of Channel Thickness
Study of Strained-SiGe Channel P-MOSFET Using Silvaco TCAD: Impact of Channel Thickness
Compressively strained SiGe is an interesting channel material for sub 45 nm p-MOSFETs because of its superior hole mobility (up to 10x over bulk Si channels) and compatibility wit...
SU‐F‐T‐473: Evaluation of Off‐Axis And Peripheral Dose Using Different Detectors
SU‐F‐T‐473: Evaluation of Off‐Axis And Peripheral Dose Using Different Detectors
Purpose:In radiation therapy, measurement of off‐axis and peripheral dose is a tedious task. The dose distribution along the beam central axis give only part of the information req...

Back to Top