SU‐F‐T‐473: Evaluation of Off‐Axis And Peripheral Dose Using Different Detectors

View through CrossRef
Purpose:In radiation therapy, measurement of off‐axis and peripheral dose is a tedious task. The dose distribution along the beam central axis give only part of the information required for an accurate dose description inside the patient. Dose distributions in 2‐D and 3‐D are determined with central axis data in conjunction with off‐axis dose profiles. Combining a central axis dose distribution with off‐axis data results in volume dose matrix that provides 2‐D and 3‐D information on dose distribution. By considering the importance of these two parameters this study investigates and compares the off axis and peripheral dose measurement using Ionization chamber, MOSFET, Radiochromic film and EDR2 film.Methods:In the measurement of off‐axis and peripheral doses 0.6cc farmer type chamber, EDR‐2 film, MD‐55 radiochromic film and MOSFET detectors were used for both 6MV and 15MV beams. The off‐axis and peripheral dose was measured at every 1 cm interval by changing the position of the couch without disturbing the other experimental setup in particular, the phantom with detector position.Results:Readings were obtained for both 6MV and 15MV photon beams at SSD technique for various field size using MOSFET, Ionization chamber and Radiochromic film. The results shows the percentage difference between various detectors for various field sizes. For Peripheral dose measurement were taken from the edge of the field size and for off axis it is measured form central axis dose.Conclusion:In conclusion, our study shows that no detector is ideal and only a comparison between different detectors highlights the weaknesses of each detector. MOSFET provides adequate dose assessment in off‐axis and peripheral regions in 6MV and 15MV photon beams. Film dosimetry in general a convenient method to generate one‐ and two‐dimensional dose distributions. The result of this indicates that MOSFET is flexible tool for relative dosimetry as films.
Title: SU‐F‐T‐473: Evaluation of Off‐Axis And Peripheral Dose Using Different Detectors
Description:
Purpose:In radiation therapy, measurement of off‐axis and peripheral dose is a tedious task.
The dose distribution along the beam central axis give only part of the information required for an accurate dose description inside the patient.
Dose distributions in 2‐D and 3‐D are determined with central axis data in conjunction with off‐axis dose profiles.
Combining a central axis dose distribution with off‐axis data results in volume dose matrix that provides 2‐D and 3‐D information on dose distribution.
By considering the importance of these two parameters this study investigates and compares the off axis and peripheral dose measurement using Ionization chamber, MOSFET, Radiochromic film and EDR2 film.
Methods:In the measurement of off‐axis and peripheral doses 0.
6cc farmer type chamber, EDR‐2 film, MD‐55 radiochromic film and MOSFET detectors were used for both 6MV and 15MV beams.
The off‐axis and peripheral dose was measured at every 1 cm interval by changing the position of the couch without disturbing the other experimental setup in particular, the phantom with detector position.
Results:Readings were obtained for both 6MV and 15MV photon beams at SSD technique for various field size using MOSFET, Ionization chamber and Radiochromic film.
The results shows the percentage difference between various detectors for various field sizes.
For Peripheral dose measurement were taken from the edge of the field size and for off axis it is measured form central axis dose.
Conclusion:In conclusion, our study shows that no detector is ideal and only a comparison between different detectors highlights the weaknesses of each detector.
MOSFET provides adequate dose assessment in off‐axis and peripheral regions in 6MV and 15MV photon beams.
Film dosimetry in general a convenient method to generate one‐ and two‐dimensional dose distributions.
The result of this indicates that MOSFET is flexible tool for relative dosimetry as films.

Related Results

Quantitative assessment of variation in CBCT image technical parameters related to CBCT detector lateral-offset position
Quantitative assessment of variation in CBCT image technical parameters related to CBCT detector lateral-offset position
Objectives: To assess the effect of CBCT detector position (aligned/lateral-offset) on image technical parameters (mean voxel value - MVV, standard deviation of voxel value (SDVV) ...
Pulse-Resolved Dosimetry Using CVD Diamond Detectors and Applications in Advanced Radiotherapy Treatment
Pulse-Resolved Dosimetry Using CVD Diamond Detectors and Applications in Advanced Radiotherapy Treatment
A pulse-by-pulse dosimetry system based on diamond material was developed for the purpose of point dose measurements that require high spatial and temporal dose resolutions during ...
A meta-evaluation of sustainable land management Initiatives in Senegal
A meta-evaluation of sustainable land management Initiatives in Senegal
Evaluation is the systematic determination of the merit, worth and significance of a programme, initiative or intervention. As a young discipline, its empirical study is still limi...
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Abstract The rapid growth of open access publishing (OAP) has significantly improved the accessibility and dissemination of scientific knowledge. However, this expansion has also c...
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract Introduction Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
Abstract 1656: Quantifying task performance with photon-processing detectors
Abstract 1656: Quantifying task performance with photon-processing detectors
Abstract Purpose. To estimate task performance (e.g., the ability to correctly detect a small lesion in a normal tissue) when the imaging system uses a new class of ...

Back to Top