Javascript must be enabled to continue!
Bolometric diagnostics in Tokamak de Varennes
View through CrossRef
Radiative power from the main and divertor plasmas of Tokamak de Varennes (TdeV) is measured using a compact bolometric diagnostic. The diagnostic is comprised of a multichannel pin-hole camera and several collimated bolometers. The electronic circuit of the bolometers permits remotely controlled in situ calibration of the detectors. The pin-hole camera, with its 17 channels of thermistor bolometers, monitors the plasma poloidal cross section horizontally. In the same camera housing reside a pair of wide angle metal film bolometers that measure the total radiative losses from the main plasma, and a 16 channel x-ray-ultraviolet photodiode array. Five collimated thermistor bolometers project the vertical view of the plasma poloidal cross section. The divertor plasma losses are monitored by six pairs of collimated thermistor bolometers installed at different toroidal locations. One pair in the lower and three pairs in the upper divertor chamber measure the global power loss from the plasma in front of the outboard divertor plates. Two other pairs of bolometers located just behind the inclined divertor plate, measure the poloidal distribution of the plasma losses from the divertor plate to the X point with an improved spatial resolution. Three divertor bolometers and one of the wide angle bolometers in the main plasma are covered with MgF2 windows, for rough spectral analysis of the radiative power loss. Examples of bolometric measurements of the radiative loss and its distribution in the TdeV during plasma detachment, plasma biasing and lower hybrid current drive and heating experiments are given.
Title: Bolometric diagnostics in Tokamak de Varennes
Description:
Radiative power from the main and divertor plasmas of Tokamak de Varennes (TdeV) is measured using a compact bolometric diagnostic.
The diagnostic is comprised of a multichannel pin-hole camera and several collimated bolometers.
The electronic circuit of the bolometers permits remotely controlled in situ calibration of the detectors.
The pin-hole camera, with its 17 channels of thermistor bolometers, monitors the plasma poloidal cross section horizontally.
In the same camera housing reside a pair of wide angle metal film bolometers that measure the total radiative losses from the main plasma, and a 16 channel x-ray-ultraviolet photodiode array.
Five collimated thermistor bolometers project the vertical view of the plasma poloidal cross section.
The divertor plasma losses are monitored by six pairs of collimated thermistor bolometers installed at different toroidal locations.
One pair in the lower and three pairs in the upper divertor chamber measure the global power loss from the plasma in front of the outboard divertor plates.
Two other pairs of bolometers located just behind the inclined divertor plate, measure the poloidal distribution of the plasma losses from the divertor plate to the X point with an improved spatial resolution.
Three divertor bolometers and one of the wide angle bolometers in the main plasma are covered with MgF2 windows, for rough spectral analysis of the radiative power loss.
Examples of bolometric measurements of the radiative loss and its distribution in the TdeV during plasma detachment, plasma biasing and lower hybrid current drive and heating experiments are given.
Related Results
Measuring the CMB primordial B-modes with Bolometric Interferometry
Measuring the CMB primordial B-modes with Bolometric Interferometry
The Q&U Bolometric Interferometer for Cosmology (QL’BIC) is the first bolometric interferometer designed to measure the primordial B-mode polarization of the Cosmic Microwave B...
Conceptual design and preliminary data analysis for classification of plasma disruption event at Aditya-U tokamak
Conceptual design and preliminary data analysis for classification of plasma disruption event at Aditya-U tokamak
Disruption prediction and its avoidance/mitigation is an essential part of the tokamak operations, particularly for large size tokamak as the disruptions could produce very large h...
Analysis of energetic particle-driven Alfvénic instabilities in tokamak and stellarator plasmas using three dimensional numerical tools
Analysis of energetic particle-driven Alfvénic instabilities in tokamak and stellarator plasmas using three dimensional numerical tools
In this thesis, a detailed analysis of the experientially observed energetic particle-driven Alfvénic instabilities in tokamak and stellarator plasmas using three dimensional numer...
Stabilized C1-bicubic finite element method for nonlinear MHD modeling of tokamak plasma
Stabilized C1-bicubic finite element method for nonlinear MHD modeling of tokamak plasma
Méthode d'éléments finis C1-bicubique stabilisée pour la modélisation MHD non linéaire du plasma de tokamak
Le tokamak est l’un des systèmes prometteurs mis au poin...
Systems of in situ diagnostics of plasma-surface interaction in MEPHIST-1 tokamak
Systems of in situ diagnostics of plasma-surface interaction in MEPHIST-1 tokamak
In the Institute for Laser and Plasma Technologies of NRNU MEPhI a compact spherical tokamak MEPhIST (MEPhI-Spherical Tokamak) for educational, demonstration and research purposes ...
Simulateur numérique de décharge de Tokamak
Simulateur numérique de décharge de Tokamak
Cette thèse s'inscrit dans le contexte de la recherche sur la fusion nucléaire par confinement magnétique d'un plasma dans un tokamak. Elle a pour objectif de développer un simulat...
Plasma column position measurements using magnetic diagnostics in ADITYA-U tokamak
Plasma column position measurements using magnetic diagnostics in ADITYA-U tokamak
Abstract
Due to several forces acting on the plasma column in a tokamak, the plasma column tends to move horizontally and/or vertically leadi...
QUBIC II: Spectral polarimetry with bolometric interferometry
QUBIC II: Spectral polarimetry with bolometric interferometry
Abstract
Bolometric interferometry is a novel technique that has the ability to perform spectral imaging. A bolometric interferometer observes the sky in a wide freq...

