Plasma column position measurements using magnetic diagnostics in ADITYA-U tokamak
View through CrossRef
Abstract
Due to several forces acting on the plasma column in a tokamak, the plasma column tends to move horizontally and/or vertically leading to many adverse events including termination of plasma. Precise measurement of plasma column position throughout the discharge with good temporal resolution in the real time is hence necessary in order to restrict the column movement using the stabilizing equilibrium magnetic fields. The plasma column position is measured by several magnetic diagnostics such as magnetic pick-up probe, Mirnov coil, Sine-Cosine coil along with flux loops in ADITYA Upgrade tokamak (ADITYA-U). In spite of the simplicity of the measurement principle of these probes as well as of their construction, obtaining the position of the plasma column is not very straightforward. The diversity of all these magnetic diagnostics in terms of their structures, installation location, mounting scenario etc leads to improper position estimations as these probes are being affected differently by the unwanted magnetic pick-ups. These unwanted pickups, especially those arising from vessel eddies, are successfully removed by introducing a scaling method for all the above-mentioned position probes in ADITYA-U based on the
in situ
calibration of these probes. The correction factors are deduced by estimating the known positions of a central current carrying conductor correctly using the probe measurements during the
in situ
calibration. These correction factors are used for estimating the plasma column position in the tokamak experiment along with proper nullification of magnetic fields arising from other magnets during tokamak operation. The plasma column position estimation from different magnetic probes are compared with each other and also with those estimated from diagnostics other than the magnetic ones.
Title: Plasma column position measurements using magnetic diagnostics in ADITYA-U tokamak
Description:
Abstract
Due to several forces acting on the plasma column in a tokamak, the plasma column tends to move horizontally and/or vertically leading to many adverse events including termination of plasma.
Precise measurement of plasma column position throughout the discharge with good temporal resolution in the real time is hence necessary in order to restrict the column movement using the stabilizing equilibrium magnetic fields.
The plasma column position is measured by several magnetic diagnostics such as magnetic pick-up probe, Mirnov coil, Sine-Cosine coil along with flux loops in ADITYA Upgrade tokamak (ADITYA-U).
In spite of the simplicity of the measurement principle of these probes as well as of their construction, obtaining the position of the plasma column is not very straightforward.
The diversity of all these magnetic diagnostics in terms of their structures, installation location, mounting scenario etc leads to improper position estimations as these probes are being affected differently by the unwanted magnetic pick-ups.
These unwanted pickups, especially those arising from vessel eddies, are successfully removed by introducing a scaling method for all the above-mentioned position probes in ADITYA-U based on the
in situ
calibration of these probes.
The correction factors are deduced by estimating the known positions of a central current carrying conductor correctly using the probe measurements during the
in situ
calibration.
These correction factors are used for estimating the plasma column position in the tokamak experiment along with proper nullification of magnetic fields arising from other magnets during tokamak operation.
The plasma column position estimation from different magnetic probes are compared with each other and also with those estimated from diagnostics other than the magnetic ones.
Related Results
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
(English) Spacecraft entering planetary atmospheres are enveloped by a plasma layer with high levels of ionization, caused by the extreme temperatures in the shock layer. The charg...
Conceptual design and preliminary data analysis for classification of plasma disruption event at Aditya-U tokamak
Conceptual design and preliminary data analysis for classification of plasma disruption event at Aditya-U tokamak
Disruption prediction and its avoidance/mitigation is an essential part of the tokamak operations, particularly for large size tokamak as the disruptions could produce very large h...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Lectin C gene analysis v1
Lectin C gene analysis v1
Mammalian Tissue Total RNA Purification Protocol by GeneJET RNA Purification Kit (Thermo Scientific, USA) Before starting: • Supplement the required amount of Lysis Buffer with β-...
Stabilized C1-bicubic finite element method for nonlinear MHD modeling of tokamak plasma
Stabilized C1-bicubic finite element method for nonlinear MHD modeling of tokamak plasma
Méthode d'éléments finis C1-bicubique stabilisée pour la modélisation MHD non linéaire du plasma de tokamak
Le tokamak est l’un des systèmes prometteurs mis au poin...
Analysis of energetic particle-driven Alfvénic instabilities in tokamak and stellarator plasmas using three dimensional numerical tools
Analysis of energetic particle-driven Alfvénic instabilities in tokamak and stellarator plasmas using three dimensional numerical tools
In this thesis, a detailed analysis of the experientially observed energetic particle-driven Alfvénic instabilities in tokamak and stellarator plasmas using three dimensional numer...
The Effect of Some Parameters on Behaviour and Bearing Capacity of Multi-Drum Stone Columns under Static Load and Earthquake
The Effect of Some Parameters on Behaviour and Bearing Capacity of Multi-Drum Stone Columns under Static Load and Earthquake
In this thesis, the effect of several important parameters on the behaviour and bearing capacity of multi-drum stone columns loaded by short-term static loads and earthquakes was i...
Simulateur numérique de décharge de Tokamak
Simulateur numérique de décharge de Tokamak
Cette thèse s'inscrit dans le contexte de la recherche sur la fusion nucléaire par confinement magnétique d'un plasma dans un tokamak. Elle a pour objectif de développer un simulat...