Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

DESCRIPTIVE STATISTICAL CALIBRATION METHOD OF TRIAXIAL DIGITAL ACCELEROMETER ADXL345 AS EARTHQUAKES SENSOR

View through CrossRef
Seismic monitoring networks are the crucial elements in strong motion seismology for effective risk reduction. Low scale lateral variation of high intensity ground movement caused by earthquakes will be detected more effectively with densely located networks. However, the limitations of developing such project are rooted in expensive costs associated with the construction and installation in addition to bulky size of the conventional seismic observation system. Recently, micro-electromechanical system (MEMS) has being recognized in the applications of seismological and earthquake engineering due to the high precision obtained in these micron size semiconductor instruments and cheaper alternative for traditional seismic detector. ADXL345 is a type of digital triaxial MEMS accelerometer that is ideal for measurement of low-frequency vibrations and static accelerations of gravity, which makes it suitable for ground motion detection. Thus, this study aims at calibrating ADXL345 sensor that is required as sensing component in an affordable earthquake monitoring system with the Earthquake Benchmarking System (Penanda Aras Gempa Bumi, PAG) available in the inventory of Department of Mineral and Geoscience Malaysia, Sabah. Soil vibrations in EW (east-west or x-axis), NS (north-south or y-axis), and UD (up-down or z-axis) directions during random forces hit on the surface are recorded by both accelerometers. Acceleration magnitudes recorded by PAG and ADXL345 are extracted and data exploration is performed. Predominantly, ADXL345 measurements in horizontal and vertical ground movements are on a higher scale than the reference device. Subsequently, evaluation by using descriptive statistical analysis is chosen to produce numerical equations for data correction operations. İmplementation of the mathematical functions in ADXL345 for observing land movements in EW, NS, and UD directions resulted in decreasing the range values of output readings. Higher approximation of magnitudes of ground motion with the PAG system is achieved.
Title: DESCRIPTIVE STATISTICAL CALIBRATION METHOD OF TRIAXIAL DIGITAL ACCELEROMETER ADXL345 AS EARTHQUAKES SENSOR
Description:
Seismic monitoring networks are the crucial elements in strong motion seismology for effective risk reduction.
Low scale lateral variation of high intensity ground movement caused by earthquakes will be detected more effectively with densely located networks.
However, the limitations of developing such project are rooted in expensive costs associated with the construction and installation in addition to bulky size of the conventional seismic observation system.
Recently, micro-electromechanical system (MEMS) has being recognized in the applications of seismological and earthquake engineering due to the high precision obtained in these micron size semiconductor instruments and cheaper alternative for traditional seismic detector.
ADXL345 is a type of digital triaxial MEMS accelerometer that is ideal for measurement of low-frequency vibrations and static accelerations of gravity, which makes it suitable for ground motion detection.
Thus, this study aims at calibrating ADXL345 sensor that is required as sensing component in an affordable earthquake monitoring system with the Earthquake Benchmarking System (Penanda Aras Gempa Bumi, PAG) available in the inventory of Department of Mineral and Geoscience Malaysia, Sabah.
Soil vibrations in EW (east-west or x-axis), NS (north-south or y-axis), and UD (up-down or z-axis) directions during random forces hit on the surface are recorded by both accelerometers.
Acceleration magnitudes recorded by PAG and ADXL345 are extracted and data exploration is performed.
Predominantly, ADXL345 measurements in horizontal and vertical ground movements are on a higher scale than the reference device.
Subsequently, evaluation by using descriptive statistical analysis is chosen to produce numerical equations for data correction operations.
İmplementation of the mathematical functions in ADXL345 for observing land movements in EW, NS, and UD directions resulted in decreasing the range values of output readings.
Higher approximation of magnitudes of ground motion with the PAG system is achieved.

Related Results

(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
Introduction Heterogeneous gas sensor arrays coupled with machine learning algorithms have been proposed for a wide range of applications. However, i...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
Access Denied
Access Denied
Introduction As social-distancing mandates in response to COVID-19 restricted in-person data collection methods such as participant observation and interviews, researchers turned t...
Development of a Mock-up of a Smart Insole Using FSR and ADXL345
Development of a Mock-up of a Smart Insole Using FSR and ADXL345
This research article describes the creation of a mock-up for a Smart Insole prototype that employs Force Sensitive Resistors (FSRs) and an ADXL345 accelerometer. The mock-up is an...
Development of a Mock-up of a Smart Insole Using FSR and ADXL345
Development of a Mock-up of a Smart Insole Using FSR and ADXL345
This research article describes the creation of a mock-up for a Smart Insole prototype that employs Force Sensitive Resistors (FSRs) and an ADXL345 accelerometer. The mock-up is an...
Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
To simplify the cross-calibration process and improve calibration frequency and accuracy, this paper proposes a cross-calibration method for the multispectral remote sensor Multi-S...
Calibration Method of Accelerometer Based on Rotation Principle Using Double Turntable Centrifuge
Calibration Method of Accelerometer Based on Rotation Principle Using Double Turntable Centrifuge
For linear accelerometers, calibration with a precision centrifuge is a key technology, and the input acceleration imposed on the accelerometer should be accurately obtained in the...
Methods matter- construct validity of steps per day in patients with lumbar spinal stenosis
Methods matter- construct validity of steps per day in patients with lumbar spinal stenosis
Abstract Purpose This study aimed to evaluate the ability of a thigh-worn accelerometer to detect walking during daily li...

Back to Top