Calibration of triaxial MEMS vector field measurement system

View through CrossRef
Triaxial MEMS vector field measurement system with triaxial MEMS sensors, such as accelerometer and magnetometer, is typically used to acquire navigation information in strap‐down inertial navigation system (SINS). The navigation accuracy of the body is directly affected by the measurement accuracy of the measurement system. This study presents a two‐step calibration algorithm for the triaxial MEMS vector field measurement system based on a detailed analysis of the measurement system error model. In the calibration procedure of this method, the first step is to calibrate the triaxial vector sensor error, including bias, scale factors and non‐orthogonality using the ellipsoid fitting method; the second step is to calibrate the misalignment between the orthogonal sensor frame and the system body frame using the four‐position method. Furthermore, the mathematical analysis of four‐position method calibration error is done to study on the factors influencing the misalignment calibration accuracy, numerical simulation and experiments, which are performed for validating the analysis. A series of calibration experiments on a triaxial MEMS accelerometer in the measurement system show significant enhancement of the accuracy of three components measurement data in the system body frame.
Title: Calibration of triaxial MEMS vector field measurement system
Description:
Triaxial MEMS vector field measurement system with triaxial MEMS sensors, such as accelerometer and magnetometer, is typically used to acquire navigation information in strap‐down inertial navigation system (SINS).
The navigation accuracy of the body is directly affected by the measurement accuracy of the measurement system.
This study presents a two‐step calibration algorithm for the triaxial MEMS vector field measurement system based on a detailed analysis of the measurement system error model.
In the calibration procedure of this method, the first step is to calibrate the triaxial vector sensor error, including bias, scale factors and non‐orthogonality using the ellipsoid fitting method; the second step is to calibrate the misalignment between the orthogonal sensor frame and the system body frame using the four‐position method.
Furthermore, the mathematical analysis of four‐position method calibration error is done to study on the factors influencing the misalignment calibration accuracy, numerical simulation and experiments, which are performed for validating the analysis.
A series of calibration experiments on a triaxial MEMS accelerometer in the measurement system show significant enhancement of the accuracy of three components measurement data in the system body frame.

Related Results

(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
Introduction Heterogeneous gas sensor arrays coupled with machine learning algorithms have been proposed for a wide range of applications. However, i...
(Invited) A 1-mG MEMS Sensor
(Invited) A 1-mG MEMS Sensor
MEMS (microelectromechanical systems) technology has contributed substantially to the miniaturization of inertial sensors, such as accelerometers and gyroscopes [1]. Nowadays, MEMS...
A MEMS IMU De-Noising Method Using Long Short Term Memory Recurrent Neural Networks (LSTM-RNN)
A MEMS IMU De-Noising Method Using Long Short Term Memory Recurrent Neural Networks (LSTM-RNN)
Microelectromechanical Systems (MEMS) Inertial Measurement Unit (IMU) containing a three-orthogonal gyroscope and three-orthogonal accelerometer has been widely utilized in positio...
A review on temperature coefficient of frequency (TCf) in resonant microelectromechanical systems (MEMS)
A review on temperature coefficient of frequency (TCf) in resonant microelectromechanical systems (MEMS)
Microelectromechanical systems (MEMS) have emerged as highly attractive alternatives to conventional commercial off-the-shelf electronic sensors and systems due to their ability to...
RELIABILITY OF MEMS ACCELEROMETERS FOR INSTRUMENTAL INTENSITY MAPPING OF EARTHQUAKES
RELIABILITY OF MEMS ACCELEROMETERS FOR INSTRUMENTAL INTENSITY MAPPING OF EARTHQUAKES
This work investigates suitability of low cost Micro-Electro Mechanical System (MEMS) sensors in strong motion related studies, particularly in shaking intensity networks. Two type...
Patients’ Perceptions of Electronic Monitoring Devices Affect Medication Adherence in Hypertensive African Americans
Patients’ Perceptions of Electronic Monitoring Devices Affect Medication Adherence in Hypertensive African Americans
Background: Electronic monitoring devices (EMDs) are regarded as the gold standard for assessing medication adherence in clinical research. However, little is k...
Dynamic calibration method for track geometry measurement system-a case study in China
Dynamic calibration method for track geometry measurement system-a case study in China
Abstract With the rapid development of railway construction, the mileage of railway detection has increased dramatically, and railway companies have higher requireme...
Heat Deformation in Optical Measurement of MEMS
Heat Deformation in Optical Measurement of MEMS
The present measurement technology in MEMS fields is not enough to produce a high performance MEMS. The measurement without any transfer of energy is required for the measurement o...

Back to Top