Force Transfer and Stress Distribution in an Implant-Supported Overdenture Retained with a Hader Bar Attachment: A Finite Element Analysis
View through CrossRef
Background and Objectives. A key factor for the long-term function of a dental implant is the manner in which stresses are transferred to the surrounding bone. The effect of adding a stiffener to the tissue side of the Hader bar helps to reduce the transmission of the stresses to the alveolar bone. But the ideal thickness of the stiffener to be attached to the bar is a subject of much debate. This study aims to analyze the force transfer and stress distribution of an implant-supported overdenture with a Hader bar attachment. The stiffener of the bar attachments was varied and the stress distribution to the bone around the implant was studied. Methods. A CT scan of edentulous mandible was used and three models with 1, 2, and 3 mm thick stiffeners were created and subjected to loads of emulating the masticatory forces. These different models were analyzed by the Finite Element Software (Ansys, Version 8.0) using von Mises stress analysis. Results. The results showed that the maximum stress concentration was seen in the neck of the implant for models A and B. In model C the maximum stress concentration was in the bar attachment making it the model with the best stress distribution, as far as implant failures are concerned. Conclusion. The implant with Hader bar attachment with a 3 mm stiffener is the best in terms of stress distribution, where the stress is concentrated at the bar and stiffener regions.
Title: Force Transfer and Stress Distribution in an Implant-Supported Overdenture Retained with a Hader Bar Attachment: A Finite Element Analysis
Description:
Background and Objectives.
A key factor for the long-term function of a dental implant is the manner in which stresses are transferred to the surrounding bone.
The effect of adding a stiffener to the tissue side of the Hader bar helps to reduce the transmission of the stresses to the alveolar bone.
But the ideal thickness of the stiffener to be attached to the bar is a subject of much debate.
This study aims to analyze the force transfer and stress distribution of an implant-supported overdenture with a Hader bar attachment.
The stiffener of the bar attachments was varied and the stress distribution to the bone around the implant was studied.
Methods.
A CT scan of edentulous mandible was used and three models with 1, 2, and 3 mm thick stiffeners were created and subjected to loads of emulating the masticatory forces.
These different models were analyzed by the Finite Element Software (Ansys, Version 8.
0) using von Mises stress analysis.
Results.
The results showed that the maximum stress concentration was seen in the neck of the implant for models A and B.
In model C the maximum stress concentration was in the bar attachment making it the model with the best stress distribution, as far as implant failures are concerned.
Conclusion.
The implant with Hader bar attachment with a 3 mm stiffener is the best in terms of stress distribution, where the stress is concentrated at the bar and stiffener regions.
Related Results
Influence of Roxolid Implant Material on The Implant Stability of Maxillary Implant Retained Overdenture
Influence of Roxolid Implant Material on The Implant Stability of Maxillary Implant Retained Overdenture
Abstract
Background
Long-term success of implant restoration depends on many factors one of them is the sufficient implant stability which is lowered in compromised bone d...
Retention Evaluation of Implant-Supported Palateless Maxillary Overdentures Retained by PEEK Telescopic Attachment
Retention Evaluation of Implant-Supported Palateless Maxillary Overdentures Retained by PEEK Telescopic Attachment
Background: Retention and stabilization of implant-supported overdenture is associated with more patient satisfaction, chewing capability, and oral health-related quality of life. ...
Implant‐Abutment Interface: Biomechanical Study of Flat Top versus Conical
Implant‐Abutment Interface: Biomechanical Study of Flat Top versus Conical
ABSTRACT Background: Overloading has been identified as a primary factor behind dental implant failure. The peak bone stresses normally appear in the marginal bone. The anchorage s...
Observation of the effect on immediate mandibular implant-supported overdenture of micro implant system of Italy
Observation of the effect on immediate mandibular implant-supported overdenture of micro implant system of Italy
The study was design to investigate the clinical effect of Micro implant system in Italy on immediate mandibular implant-supported overdenture. A total of 192 patients with mandibu...
How the initial retentive force of implant-supported overdentures can be affected with splinted and unsplinted attachments systems
How the initial retentive force of implant-supported overdentures can be affected with splinted and unsplinted attachments systems
Background:
The aim of this study was to evaluate the retention of implant-supported overdentures with different attachment systems.
M...
Clinical performance of implant supported mandibular overdentures with cantilever bar and stud attachments: A retrospective study
Clinical performance of implant supported mandibular overdentures with cantilever bar and stud attachments: A retrospective study
AbstractBackgroundTreatment of edentulous patients with implant‐supported over‐dentures improves denture's retention and stability. Published data concerning implant‐supported over...
Finite Element Analysis (FEA) of Palatal Coverage on Implant Retained Maxillary Overdentures
Finite Element Analysis (FEA) of Palatal Coverage on Implant Retained Maxillary Overdentures
Purpose: The aim of this study was to determine stress levels on supporting structures of implant-retained overdentures as a function of varying degrees of palatal coverage using f...
Stress and Strain Analysis of the Bone-Implant Interface: A Comparison of Fiber-Reinforced Composite and Titanium Implants Utilizing 3-Dimensional Finite Element Study
Stress and Strain Analysis of the Bone-Implant Interface: A Comparison of Fiber-Reinforced Composite and Titanium Implants Utilizing 3-Dimensional Finite Element Study
This study analyzed stress and strain mediated by 2 different implant materials, titanium (Ti) and experimental fiber-reinforced composite (FRC), on the implant and on the bone tis...