Measurement of Power Frequency Current including Low- and High-Order Harmonics Using a Rogowski Coil

View through CrossRef
The measurement of a power frequency current including low- and high-order harmonics is of great importance in calibration as well as in testing processes. Therefore, this paper presents the measurement of the power frequency current of light-emitting diode (LED) luminaires. LED luminaires were chosen as their input current includes both low- and high-order harmonics. The measurement process depends on reconstructing an LED luminaire current without using the coil parameters. Hence, the current reconstruction process is designed to be dependent on the measured characteristics of the Rogowski coil itself considering the frequency range at which the measurement process is required. An evaluation of the proposed measurement process was theoretically and experimentally carried out. A theoretical evaluation was carried out using MATALB SIMULINK software. However, the experimental evaluation was performed by building a Rogowski coil to measure the input currents of different LED luminaires having different power ratings of 300 W, 400 W, and 600 W. The currents measured using the Rogowski coil were compared with reference currents measured using a standard measurement technique. The obtained results show the efficacy of the proposed measurement method.
Title: Measurement of Power Frequency Current including Low- and High-Order Harmonics Using a Rogowski Coil
Description:
The measurement of a power frequency current including low- and high-order harmonics is of great importance in calibration as well as in testing processes.
Therefore, this paper presents the measurement of the power frequency current of light-emitting diode (LED) luminaires.
LED luminaires were chosen as their input current includes both low- and high-order harmonics.
The measurement process depends on reconstructing an LED luminaire current without using the coil parameters.
Hence, the current reconstruction process is designed to be dependent on the measured characteristics of the Rogowski coil itself considering the frequency range at which the measurement process is required.
An evaluation of the proposed measurement process was theoretically and experimentally carried out.
A theoretical evaluation was carried out using MATALB SIMULINK software.
However, the experimental evaluation was performed by building a Rogowski coil to measure the input currents of different LED luminaires having different power ratings of 300 W, 400 W, and 600 W.
The currents measured using the Rogowski coil were compared with reference currents measured using a standard measurement technique.
The obtained results show the efficacy of the proposed measurement method.

Related Results

Improving the sensitivity of a PCB Rogowski coil current sensor with split-plate summation
Improving the sensitivity of a PCB Rogowski coil current sensor with split-plate summation
As a promising current sensor for high-frequency pulsed current monitoring, printed circuit board (PCB) Rogowski coils demonstrate distinct advantages, including extended bandwidth...
The Rogowski Coil Technology Advancements: A Review of High Current Applications
The Rogowski Coil Technology Advancements: A Review of High Current Applications
Rogowski coil (RC) also known as air-cored was suggested in 1912 and was introduced by German physician Walter Rogowski. This coil is developed for the measurement of alternating a...
PCB Rogowski Coil sensor by using Saw blade pattern for arcing fault detection
PCB Rogowski Coil sensor by using Saw blade pattern for arcing fault detection
Abstract Rogowski is a special current transformer and has been categorised as a low-power stand-alone current sensor. This sensor is designed by using a Saw blade p...
Pengujian Peluahan Sebagian Menggunakan Rogowski Coil Inti Ferit dan Non Ferit dengan Variaasi Lilitan Sebanyak 10 Lilitan
Pengujian Peluahan Sebagian Menggunakan Rogowski Coil Inti Ferit dan Non Ferit dengan Variaasi Lilitan Sebanyak 10 Lilitan
Partial Discharge is one of the phenomena that occurs in the electric power system, which is characterized by the phenomenon of heat which will disrupt the insulation system. If th...
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
E-019 Novel bioactive coil with modified PGLA
E-019 Novel bioactive coil with modified PGLA
PurposeNovel Bioactive Coil with modified PGLA was developed to further improve biological reaction induced by currently available PGLA coils.MethodPrototype coil materials were pr...
Harmonics In Offshore Electrical Power System
Harmonics In Offshore Electrical Power System
Abstract Recently Electrical Submersible Pumps (ESPs) are being widely used in the depleting oil fields with low pressure (Dead Crude) and in deep wells with marg...
Autonomous Lightning Strike Detection and Counting System Using Rogowski Coil Current Measurement
Autonomous Lightning Strike Detection and Counting System Using Rogowski Coil Current Measurement
Lightning strikes are a leading cause of outages on overhead transmission lines, significantly compromising power system reliability. Consequently, monitoring lightning activity is...

Back to Top