Autonomous Lightning Strike Detection and Counting System Using Rogowski Coil Current Measurement

View through CrossRef
Lightning strikes are a leading cause of outages on overhead transmission lines, significantly compromising power system reliability. Consequently, monitoring lightning activity is critical to mitigate its impact on lines with high outage rates. This study presents an autonomous lightning strike counter system utilizing a split-core Rogowski coil for non-invasive current measurement on transmission towers. The system combines the Rogowski coil with an active integrator circuit to reconstruct the incident current waveform from the coil voltage signal. A microcontroller-based processing unit records strike occurrences and classifies them by amplitude using predefined thresholds. Laboratory tests were carried out to evaluate the performance of the Rogowski coil and integrator circuit, validating the system accuracy in detecting current pulses associated with lightning strikes. Underway field tests will assess the sensor’s reliability during long-term autonomous operation on 345-kV transmission towers. The results demonstrate that the proposed system represents a practical and cost-effective solution for lightning monitoring in remote areas, contributing to enhanced data collection for engineering studies and improved reliability of electrical infrastructure.
Title: Autonomous Lightning Strike Detection and Counting System Using Rogowski Coil Current Measurement
Description:
Lightning strikes are a leading cause of outages on overhead transmission lines, significantly compromising power system reliability.
Consequently, monitoring lightning activity is critical to mitigate its impact on lines with high outage rates.
This study presents an autonomous lightning strike counter system utilizing a split-core Rogowski coil for non-invasive current measurement on transmission towers.
The system combines the Rogowski coil with an active integrator circuit to reconstruct the incident current waveform from the coil voltage signal.
A microcontroller-based processing unit records strike occurrences and classifies them by amplitude using predefined thresholds.
Laboratory tests were carried out to evaluate the performance of the Rogowski coil and integrator circuit, validating the system accuracy in detecting current pulses associated with lightning strikes.
Underway field tests will assess the sensor’s reliability during long-term autonomous operation on 345-kV transmission towers.
The results demonstrate that the proposed system represents a practical and cost-effective solution for lightning monitoring in remote areas, contributing to enhanced data collection for engineering studies and improved reliability of electrical infrastructure.

Related Results

Radio pulse power distribution of lightning in Jupiter's 2021-2022 stealth superstorms
Radio pulse power distribution of lightning in Jupiter's 2021-2022 stealth superstorms
OverviewJovian lightning has been investigated by every spacecraft mission that visited Jupiter prior to Juno. Lightning is valued because it traces locations with active moist con...
Improving the sensitivity of a PCB Rogowski coil current sensor with split-plate summation
Improving the sensitivity of a PCB Rogowski coil current sensor with split-plate summation
As a promising current sensor for high-frequency pulsed current monitoring, printed circuit board (PCB) Rogowski coils demonstrate distinct advantages, including extended bandwidth...
Long-range Lightning Interferometry (A Simulation Study)
Long-range Lightning Interferometry (A Simulation Study)
Traditional long-range lightning detection and location networks use Time-of-Arrival (TOA) differences, and a single timestamp to locate lightning events. For long propagation dist...
Analysis Duration of Potential Difference Neutralizer for Substation Grounding System
Analysis Duration of Potential Difference Neutralizer for Substation Grounding System
The grounding system design of the 150 kV substation have resolve affect in lightning strike area. The purpose of this study is to determine the duration of the potential differenc...
Lightning Activity in China and Its Optical Characteristics Observed by Geostationary Satellite
Lightning Activity in China and Its Optical Characteristics Observed by Geostationary Satellite
Lightning now has designated as an Essential Climate Variable in the Global Climate Observing System to understand the climate change. Lightning detection from geostationary satell...
Pengujian Peluahan Sebagian Menggunakan Rogowski Coil Inti Ferit dan Non Ferit dengan Variaasi Lilitan Sebanyak 10 Lilitan
Pengujian Peluahan Sebagian Menggunakan Rogowski Coil Inti Ferit dan Non Ferit dengan Variaasi Lilitan Sebanyak 10 Lilitan
Partial Discharge is one of the phenomena that occurs in the electric power system, which is characterized by the phenomenon of heat which will disrupt the insulation system. If th...
PCB Rogowski Coil sensor by using Saw blade pattern for arcing fault detection
PCB Rogowski Coil sensor by using Saw blade pattern for arcing fault detection
Abstract Rogowski is a special current transformer and has been categorised as a low-power stand-alone current sensor. This sensor is designed by using a Saw blade p...