Rogowski is a special current transformer and has been categorised as a low-power stand-alone current sensor. This sensor is designed by using a Saw blade pattern with 50 turns and 100 turns. This number of turns will impact the increment of the sensitivity of the sensor. Rogowski coil is used for measuring the alternating current (AC) and high-speed current pulses. The PCB Rogowski Coil will detect the arcing fault that design with AutoCAD software after that import to CST software. An arc is created when the electrical current jumps the gap between two conductive materials. The most common causes of arcs include worn contacts in electrical equipment, damage to insulation, break in a cable and loose connections. In order to reduce the arc fault risk, the arc fault interrupter (AFI) technology and arc fault detectors (AFD) have been developed. However, these devices are most suitable for domestic application or low voltage (LV). This paper proposed a simulation using AutoCAD and CST software to design a Rogowski coil and the Rogowski Coil sensor will be tested by using CST software in terms of radiation pattern. The biggest radiation pattern in red colour is the saw blade pattern in 100 turns at 2 KHz frequency, the radiation pattern covering entire sensor area compared with other radiation patterns with other frequency. The main lobe magnitude for 2 KHz frequency is 46.8 dB, main lobe direction is 180 deg, angular width is 153.4 deg and the side lobe level is zero. This is the best number of turn and frequency compared to 50 turn saw blade sensor.
Title: PCB Rogowski Coil sensor by using Saw blade pattern for arcing fault detection
Description:
Abstract
Rogowski is a special current transformer and has been categorised as a low-power stand-alone current sensor.
This sensor is designed by using a Saw blade pattern with 50 turns and 100 turns.
This number of turns will impact the increment of the sensitivity of the sensor.
Rogowski coil is used for measuring the alternating current (AC) and high-speed current pulses.
The PCB Rogowski Coil will detect the arcing fault that design with AutoCAD software after that import to CST software.
An arc is created when the electrical current jumps the gap between two conductive materials.
The most common causes of arcs include worn contacts in electrical equipment, damage to insulation, break in a cable and loose connections.
In order to reduce the arc fault risk, the arc fault interrupter (AFI) technology and arc fault detectors (AFD) have been developed.
However, these devices are most suitable for domestic application or low voltage (LV).
This paper proposed a simulation using AutoCAD and CST software to design a Rogowski coil and the Rogowski Coil sensor will be tested by using CST software in terms of radiation pattern.
The biggest radiation pattern in red colour is the saw blade pattern in 100 turns at 2 KHz frequency, the radiation pattern covering entire sensor area compared with other radiation patterns with other frequency.
The main lobe magnitude for 2 KHz frequency is 46.
8 dB, main lobe direction is 180 deg, angular width is 153.
4 deg and the side lobe level is zero.
This is the best number of turn and frequency compared to 50 turn saw blade sensor.
Related Results
Improving the sensitivity of a PCB Rogowski coil current sensor with split-plate summation
Improving the sensitivity of a PCB Rogowski coil current sensor with split-plate summation
As a promising current sensor for high-frequency pulsed current monitoring, printed circuit board (PCB) Rogowski coils demonstrate distinct advantages, including extended bandwidth...
Integration Techniques of Fault Detection and Isolation Using Interval Observers
Integration Techniques of Fault Detection and Isolation Using Interval Observers
An interval observer has been illustrated to be a suitable approach to detect and isolate faults affecting complex dynamical industrial systems.
Concerning fault detection, interv...
Rancang Bangun Pembuat Layout PCB Otomatis Berbasis Android
Rancang Bangun Pembuat Layout PCB Otomatis Berbasis Android
ABSTRACT
The purpose of this research is to produce an Android-based automatic PCB layout path maker tool. This tool can automatically create a PCB layout path without etchin...
Pengujian Peluahan Sebagian Menggunakan Rogowski Coil Inti Ferit dan Non Ferit dengan Variaasi Lilitan Sebanyak 10 Lilitan
Pengujian Peluahan Sebagian Menggunakan Rogowski Coil Inti Ferit dan Non Ferit dengan Variaasi Lilitan Sebanyak 10 Lilitan
Partial Discharge is one of the phenomena that occurs in the electric power system, which is characterized by the phenomenon of heat which will disrupt the insulation system. If th...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
Deformational Processes Accommodating Slip on an Active Low-Angle Normal Fault, Suckling-Dayman Metamorphic Core Complex, Papua New Guinea
Deformational Processes Accommodating Slip on an Active Low-Angle Normal Fault, Suckling-Dayman Metamorphic Core Complex, Papua New Guinea
<p><b>Detachment faults that can be shown to have slipped at dips <30° in highly extended continental crust are referred to as “Low-Angle Normal Faults” (LANFs). The...
Arcing fault diagnosis using first peak arrival of EM radiation signal
Arcing fault diagnosis using first peak arrival of EM radiation signal
Abstract
The objective of this study was to diagnose the arcing fault signals based on the first peak of arrival method using antenna to assess its use as potential ...
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Abstract:Little attention had been paid to the intracontinental strike‐slip faults of the Tibetan Plateau. Since the discovery of the Longriba fault using re‐measured GPS data in 2...