E-019 Novel bioactive coil with modified PGLA
View through CrossRef
PurposeNovel Bioactive Coil with modified PGLA was developed to further improve biological reaction induced by currently available PGLA coils.MethodPrototype coil materials were prepared by coating the currently available PGLA coils (matrix coil) with chemically modified PGLA. A total of 12 side wall aneurysms were surgically created in six swine. Four aneurysms were treated with Novel Bioactive Coil, four aneurysms were treated with 90/10 PGLA coils and four aneurysms were treated with bare platinum coil (Gugliemi Detachable Coils), respectively. All animals were kept alive for 14 days after the procedure. Histologic as well as immunohistochemical analyses were performed on each harvested sample.ResultsMacroscopic findings showed that significantly advanced thrombus organization was observed in the Novel Bioactive Coil group compared with the PGLA coil group and the bare platinum coil group. The granulation tissue induced by Novel Bioactive Coil was characterized by its intensive migration of multinuclear giant cells, profound microvascular proliferation and vacuole formation around the coil materials. Qualitative histological analysis showed that Novel Bioactive Coil elicited the most prominent macrophage expression, followed by PGLA coils and bare platinum coil.ConclusionNovel Bioactive Coil has a potential to elicit more accelerated thrombus organization compared with currently used coil materials, including bare platinum coil and PGLA coil.Abstract E-019 Figure 1
Title: E-019 Novel bioactive coil with modified PGLA
Description:
PurposeNovel Bioactive Coil with modified PGLA was developed to further improve biological reaction induced by currently available PGLA coils.
MethodPrototype coil materials were prepared by coating the currently available PGLA coils (matrix coil) with chemically modified PGLA.
A total of 12 side wall aneurysms were surgically created in six swine.
Four aneurysms were treated with Novel Bioactive Coil, four aneurysms were treated with 90/10 PGLA coils and four aneurysms were treated with bare platinum coil (Gugliemi Detachable Coils), respectively.
All animals were kept alive for 14 days after the procedure.
Histologic as well as immunohistochemical analyses were performed on each harvested sample.
ResultsMacroscopic findings showed that significantly advanced thrombus organization was observed in the Novel Bioactive Coil group compared with the PGLA coil group and the bare platinum coil group.
The granulation tissue induced by Novel Bioactive Coil was characterized by its intensive migration of multinuclear giant cells, profound microvascular proliferation and vacuole formation around the coil materials.
Qualitative histological analysis showed that Novel Bioactive Coil elicited the most prominent macrophage expression, followed by PGLA coils and bare platinum coil.
ConclusionNovel Bioactive Coil has a potential to elicit more accelerated thrombus organization compared with currently used coil materials, including bare platinum coil and PGLA coil.
Abstract E-019 Figure 1.
Related Results
Abstract TP89: Ultra Thin Bioabsorbable Polymeric Coating On The Surface Of Coil Materials For Brain Aneurysms Treatment
Abstract TP89: Ultra Thin Bioabsorbable Polymeric Coating On The Surface Of Coil Materials For Brain Aneurysms Treatment
Purpose:
A novel bioactive coil material, which is composed of a bare platinum core coated with an ultrathin layer of 50/50 acidified PGLA was developed for the purpose...
Coil migration during coronary artery fistula transcatheter embolization
Coil migration during coronary artery fistula transcatheter embolization
Link of Video Abstract: https://youtu.be/qD-dDYr0m2U
Introduction: Coronary artery fistula (CAF) transcatheter coil embolization is very effective in treating symptomatic coronar...
Current control and tuning in a closed HTS coil
Current control and tuning in a closed HTS coil
Up to today, a coil made of high temperature superconductor (HTS) usually needs a soldered joint to form a closed circuit. It is very difficult to have the joint fully superconduct...
Improving the Thermofluid Performance of a Shell and Corrugated Coil Heat Exchanger With Novel Configurations
Improving the Thermofluid Performance of a Shell and Corrugated Coil Heat Exchanger With Novel Configurations
Abstract
In the current investigation, novel coil configurations of a shell and corrugated coil heat exchanger (SCCHX) were experimentally examined and compared w...
Structure improved design and intensity experiment on drive coil
Structure improved design and intensity experiment on drive coil
To sustain the strength of electromagnetic force, according to the stress distribution of a drive coil, the prime design requirements of the drive coil are presented, the drive coi...
Magneto-Electric Antenna and Its Application in Geosteering Tool Design
Magneto-Electric Antenna and Its Application in Geosteering Tool Design
Using coil antennae as transmitter and receiver to develop a geosteering tool, one has to increase the spacing between the transmitter and receiver to detect formation boundaries f...
Design 3D Printed Coils for WPT
Design 3D Printed Coils for WPT
Abstract
The geometric shapes of coils influence the performance of a 3D IPT system. In this paper, we proposed a 3D coil design method based on (3D) printing electr...
Signal-to-Noise Ratio and Contrast-to-Noise Ratio Comparisons Between a Wireless Volume Radiofrequency Coil and a Commercially Available Wired Radiofrequency Coil
Signal-to-Noise Ratio and Contrast-to-Noise Ratio Comparisons Between a Wireless Volume Radiofrequency Coil and a Commercially Available Wired Radiofrequency Coil
The design of magnetic resonance imaging (MRI) radiofrequency (RF) coils plays a critical role in determining image quality, with signal-to-noise ratio (SNR) and contrast-to-noise ...