Alumina Trihydrate Effect on Flashover Voltage of Polyester Insulators by Whale Optimization Algorithm Technique

View through CrossRef
Ceramic materials are commonly used as outdoor insulators for high-voltage power transmission lines. Presently, these ceramic insulators are replaced by composite polymeric insulators with polyester, especially in rainy areas. Unlike ceramic materials, polymer materials have a shorter life, so fillers are used to improve their physical and chemical properties. This paper aims to improve the flashover voltage performance of polyester loaded with Alumina Trihydrate filler in wet weather condition. Due to the high cost of raw materials (polyester and Alumina Trihydrate filler), the Whale Optimization Algorithm model was used to predict the best concentration of Alumina Trihydrate filler to give the best value of flashover voltage. The model is based on experimental data of flashover voltage measurements. A positive correlation of the calculations from the Whale Optimization Algorithm model with experimental data has been demonstrated. The results showed that the flashover voltage performance of polyester is increased with the increase of Alumina Trihydrate filler concentration. Also, the optimum concentration of Alumina Trihydrate filler and flashover values predicted by the MATLAB Whale Optimization Algorithm are very accurate.
Title: Alumina Trihydrate Effect on Flashover Voltage of Polyester Insulators by Whale Optimization Algorithm Technique
Description:
Ceramic materials are commonly used as outdoor insulators for high-voltage power transmission lines.
Presently, these ceramic insulators are replaced by composite polymeric insulators with polyester, especially in rainy areas.
Unlike ceramic materials, polymer materials have a shorter life, so fillers are used to improve their physical and chemical properties.
This paper aims to improve the flashover voltage performance of polyester loaded with Alumina Trihydrate filler in wet weather condition.
Due to the high cost of raw materials (polyester and Alumina Trihydrate filler), the Whale Optimization Algorithm model was used to predict the best concentration of Alumina Trihydrate filler to give the best value of flashover voltage.
The model is based on experimental data of flashover voltage measurements.
A positive correlation of the calculations from the Whale Optimization Algorithm model with experimental data has been demonstrated.
The results showed that the flashover voltage performance of polyester is increased with the increase of Alumina Trihydrate filler concentration.
Also, the optimum concentration of Alumina Trihydrate filler and flashover values predicted by the MATLAB Whale Optimization Algorithm are very accurate.

Related Results

Influence of zinc oxide nanoparticles on flashover voltage of unsaturated polyester resin-based composites for electrical insulators
Influence of zinc oxide nanoparticles on flashover voltage of unsaturated polyester resin-based composites for electrical insulators
Introduction. Polyester-based composites are increasingly used in electrical applications for their insulation, mechanical, and thermal properties. Nanofillers have shown promise i...
Simulation of DC surface flashover of epoxy composites in compressed nitrogen
Simulation of DC surface flashover of epoxy composites in compressed nitrogen
To date, numerical simulation techniques for surface flashover are still under development. In this work, a DC surface flashover numerical simulation model is constructed based on ...
Pollution Flashover Characteristics of Composite Crossarm Insulator with a Large Diameter
Pollution Flashover Characteristics of Composite Crossarm Insulator with a Large Diameter
The composite crossarm insulator differs greatly from the suspension insulator in structure and arrangement. This study aims to determine the pollution flashover characteristics of...
Flashover Performance and Process of Suspension Insulator Strings Artificially Covered with Snow
Flashover Performance and Process of Suspension Insulator Strings Artificially Covered with Snow
Snow accumulates on the surface of insulator string, causing a decrease in its electrical performance, seriously threatening the reliable operation of the power grid. Most previous...
Influence of snow accretion on arc flashover gradient for various types of insulators
Influence of snow accretion on arc flashover gradient for various types of insulators
Atmospheric snow accretion along the insulators can eventually bridge adjacent shed spacing, which pose severe risks to the security of power networks. Aiming to investigate the in...
Analysis and Comparison of Pollution Flashover Performance of Porcelain Insulators in Distribution System 22 kV
Analysis and Comparison of Pollution Flashover Performance of Porcelain Insulators in Distribution System 22 kV
Electrical insulators of the Provincial Electricity Authority (PEA) of medium system are mostly porcelain insulator types that consist of pin type, line post, and pin post insulato...
The application of baleen whale genomes in conservation and evolutionary research
The application of baleen whale genomes in conservation and evolutionary research
Baleen whales (Mysticeti) are a clade of highly adapted carnivorous marine mammals that can reach extremely large body sizes and feature characteristic keratinaceous baleen plates ...
Comparison of natural contamination accumulation characteristics between composite rod insulators and standard suspended insulator strings
Comparison of natural contamination accumulation characteristics between composite rod insulators and standard suspended insulator strings
In order to attain the pollution characteristics difference between composite rod insulators and standard disc‐type suspended insulator which is critical to the insulation selectio...