Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Comparison of natural contamination accumulation characteristics between composite rod insulators and standard suspended insulator strings

View through CrossRef
In order to attain the pollution characteristics difference between composite rod insulators and standard disc‐type suspended insulator which is critical to the insulation selection of transmission line, pollution accumulated on composite rod insulators and standard form suspended insulators suspended in the same tower near typical pollution sources in Zhejiang province were tested, including the equivalent salt deposit density (ESDD) and the non‐soluble deposit density (NSDD). Also the factors caused the difference were analysed for the first time. It is shown that in Zhejiang area, the contamination on upper surface of composite insulators is more serious than that of standard form suspended insulators, and the situation is inverse on the lower surface; the entire shed value of ESDD and NSDD from composite insulator is 0.8, 1.27 times of the values from standard form suspended insulators, respectively. The contamination difference of upper surface and lower surface of the composite insulators is smaller than that of standard form suspended insulators. According to the analysis, the rainfall and PM10 concentration could notably effect the ESDD difference between composite insulators and standard form suspended insulators. With stronger rainfall and less PM10 concentration, the ESDD ration of composite insulators and standard form suspended insulators trend to be smaller.
Title: Comparison of natural contamination accumulation characteristics between composite rod insulators and standard suspended insulator strings
Description:
In order to attain the pollution characteristics difference between composite rod insulators and standard disc‐type suspended insulator which is critical to the insulation selection of transmission line, pollution accumulated on composite rod insulators and standard form suspended insulators suspended in the same tower near typical pollution sources in Zhejiang province were tested, including the equivalent salt deposit density (ESDD) and the non‐soluble deposit density (NSDD).
Also the factors caused the difference were analysed for the first time.
It is shown that in Zhejiang area, the contamination on upper surface of composite insulators is more serious than that of standard form suspended insulators, and the situation is inverse on the lower surface; the entire shed value of ESDD and NSDD from composite insulator is 0.
8, 1.
27 times of the values from standard form suspended insulators, respectively.
The contamination difference of upper surface and lower surface of the composite insulators is smaller than that of standard form suspended insulators.
According to the analysis, the rainfall and PM10 concentration could notably effect the ESDD difference between composite insulators and standard form suspended insulators.
With stronger rainfall and less PM10 concentration, the ESDD ration of composite insulators and standard form suspended insulators trend to be smaller.

Related Results

Simulation Analysis of Voltage Distribution of 500kV Degraded Magnetic Insulator String
Simulation Analysis of Voltage Distribution of 500kV Degraded Magnetic Insulator String
Abstract Insulators are important power grid equipment and key components to ensure electrical insulation performance. Porcelain insulators with reduced insulation p...
Ribbon Rod - Improvement in Sucker Rod Technology Shows Need to Re-Evaluate Current Artificial Lift Installations
Ribbon Rod - Improvement in Sucker Rod Technology Shows Need to Re-Evaluate Current Artificial Lift Installations
Abstract This study describes ribbon rod as a continuous graphite composite material that can be currently used to partially replace a conventional sucker rod str...
Direct Selection of Functional Insulators in Arabidopsis thaliana
Direct Selection of Functional Insulators in Arabidopsis thaliana
Abstract Background: Insulators are DNA sequences found in all eucaryotes. By forming DNA-protein complexes in vivo they regulate enhancer-promoter interactions and define ...
Influence of snow accretion on arc flashover gradient for various types of insulators
Influence of snow accretion on arc flashover gradient for various types of insulators
Atmospheric snow accretion along the insulators can eventually bridge adjacent shed spacing, which pose severe risks to the security of power networks. Aiming to investigate the in...
Flashover Performance and Process of Suspension Insulator Strings Artificially Covered with Snow
Flashover Performance and Process of Suspension Insulator Strings Artificially Covered with Snow
Snow accumulates on the surface of insulator string, causing a decrease in its electrical performance, seriously threatening the reliable operation of the power grid. Most previous...
Railroad Catenary Insulator Fault Detection Based on Improved Faster R-CNN
Railroad Catenary Insulator Fault Detection Based on Improved Faster R-CNN
Background: The railroad catenary insulator, which is a crucial component of the catenary system and is situated between the pillar and wrist arm, is crucial for electrical conduct...
Rod bipolar cells in the macaque monkey retina: immunoreactivity and connectivity
Rod bipolar cells in the macaque monkey retina: immunoreactivity and connectivity
Rod bipolar cells in the macaque monkey retina were labeled by three antibodies: an antibody against the alpha- and beta-subspecies of protein kinase C (PKC), a polyclonal antiseru...

Back to Top