Analysis and Comparison of Pollution Flashover Performance of Porcelain Insulators in Distribution System 22 kV
View through CrossRef
Electrical insulators of the Provincial Electricity Authority (PEA) of medium system are mostly porcelain insulator types that consist of pin type, line post, and pin post insulators. The distribution lines will be polluted by industrial contaminants, salt fog or natural dust. Experience shows that pollution flashover is one of the main natural calamities harming and affecting the voltage stability and reliability of distribution system. This paper compares the test results obtained from the artificial pollution tests according to IEC 60507 in the chamber for tests with standard porcelain insulators consist, pin post, line post and pin type insulators of medium system under same test conditions. The salt fog test results indicate that the pollution flashover performance of pin type insulator is less than to 50 percent of wet power frequency withstand voltage at equivalent salt deposit density (ESDD) = 0.5 mg/cm2 and the leakage current (LC) of pin type insulator increased to 11.4 mA at ESDD = 0.5 mg/cm2 at nominal voltage. In the experiment indicate that AC pollution flashover performance of pin post insulator has better than line post and pin type insulators in the serious pollution area. This data will be useful to be guideline for solving problems and reducing power loss from leakage current on the surface of the insulators as a result of surface dirt and pollution. Moreover, it will be useful to select or design suitable insulators for using in places with salt conditions, high rainfall, high wind speeds and high humidity.
Trans Tech Publications, Ltd.
Title: Analysis and Comparison of Pollution Flashover Performance of Porcelain Insulators in Distribution System 22 kV
Description:
Electrical insulators of the Provincial Electricity Authority (PEA) of medium system are mostly porcelain insulator types that consist of pin type, line post, and pin post insulators.
The distribution lines will be polluted by industrial contaminants, salt fog or natural dust.
Experience shows that pollution flashover is one of the main natural calamities harming and affecting the voltage stability and reliability of distribution system.
This paper compares the test results obtained from the artificial pollution tests according to IEC 60507 in the chamber for tests with standard porcelain insulators consist, pin post, line post and pin type insulators of medium system under same test conditions.
The salt fog test results indicate that the pollution flashover performance of pin type insulator is less than to 50 percent of wet power frequency withstand voltage at equivalent salt deposit density (ESDD) = 0.
5 mg/cm2 and the leakage current (LC) of pin type insulator increased to 11.
4 mA at ESDD = 0.
5 mg/cm2 at nominal voltage.
In the experiment indicate that AC pollution flashover performance of pin post insulator has better than line post and pin type insulators in the serious pollution area.
This data will be useful to be guideline for solving problems and reducing power loss from leakage current on the surface of the insulators as a result of surface dirt and pollution.
Moreover, it will be useful to select or design suitable insulators for using in places with salt conditions, high rainfall, high wind speeds and high humidity.
Related Results
Pollution Flashover Characteristics of Composite Crossarm Insulator with a Large Diameter
Pollution Flashover Characteristics of Composite Crossarm Insulator with a Large Diameter
The composite crossarm insulator differs greatly from the suspension insulator in structure and arrangement. This study aims to determine the pollution flashover characteristics of...
Simulation of DC surface flashover of epoxy composites in compressed nitrogen
Simulation of DC surface flashover of epoxy composites in compressed nitrogen
To date, numerical simulation techniques for surface flashover are still under development. In this work, a DC surface flashover numerical simulation model is constructed based on ...
Influence of snow accretion on arc flashover gradient for various types of insulators
Influence of snow accretion on arc flashover gradient for various types of insulators
Atmospheric snow accretion along the insulators can eventually bridge adjacent shed spacing, which pose severe risks to the security of power networks. Aiming to investigate the in...
Flashover Performance and Process of Suspension Insulator Strings Artificially Covered with Snow
Flashover Performance and Process of Suspension Insulator Strings Artificially Covered with Snow
Snow accumulates on the surface of insulator string, causing a decrease in its electrical performance, seriously threatening the reliable operation of the power grid. Most previous...
Influence of zinc oxide nanoparticles on flashover voltage of unsaturated polyester resin-based composites for electrical insulators
Influence of zinc oxide nanoparticles on flashover voltage of unsaturated polyester resin-based composites for electrical insulators
Introduction. Polyester-based composites are increasingly used in electrical applications for their insulation, mechanical, and thermal properties. Nanofillers have shown promise i...
Comparison of natural contamination accumulation characteristics between composite rod insulators and standard suspended insulator strings
Comparison of natural contamination accumulation characteristics between composite rod insulators and standard suspended insulator strings
In order to attain the pollution characteristics difference between composite rod insulators and standard disc‐type suspended insulator which is critical to the insulation selectio...
Simulation Analysis of Voltage Distribution of 500kV Degraded Magnetic Insulator String
Simulation Analysis of Voltage Distribution of 500kV Degraded Magnetic Insulator String
Abstract
Insulators are important power grid equipment and key components to ensure electrical insulation performance. Porcelain insulators with reduced insulation p...
Experimental study and mathematical modelling of flashover on extra‐high voltage insulators covered with ice
Experimental study and mathematical modelling of flashover on extra‐high voltage insulators covered with ice
AbstractUsing a test method developed at the high‐voltage laboratory of the NSERC/Hydro‐Quebec/UQAC Industrial Chair on Atmospheric Icing of Power Network Equipment (CIGELE), the r...