Pollution Flashover Characteristics of Composite Crossarm Insulator with a Large Diameter
View through CrossRef
The composite crossarm insulator differs greatly from the suspension insulator in structure and arrangement. This study aims to determine the pollution flashover characteristics of composite crossarm insulators under different voltage grades. Four types of AC composite crossarm insulators with diameters ranging from 100 mm to 450 mm are subjected to artificial pollution test, and then the effects of the surface hydrophobicity state of silicone rubber, core diameter, umbrella structure, arrangement, and insulation distance on the pollution flashover voltage of the composite crossarm insulators are analyzed. Under the pollution grade 0.2/1.0 mg/cm2 and voltage grade from 66 kV to 1000 kV, if the silicone rubber surface changes from HC5 to HC6, the pollution flashover voltage of the composite crossarm insulator will increase by 13.5% to 21.0% compared with the hydrophilic surface. If the core diameter changes from 100 mm to 300 mm, the pollution flashover voltage gradient decreases with the increase in core diameter; if the core diameter changes from 300 mm to 450 mm, the pollution flashover voltage gradient increases with core diameter. Under the same insulation height and core diameter, the umbrella structure will have a certain impact on pollution flashover voltage by up to 1.7% to 5.4%. Under the horizontal arrangement, the pollution flashover voltage can increase by 10.5% to 12.1% compared with that under the vertical arrangement. Under the hydrophilic surface and weak hydrophobicity state, the pollution flashover voltage has a linear relationship with the insulation distance. The above results can provide a reference for the structural design and optimization of the composite crossarm insulator.
Title: Pollution Flashover Characteristics of Composite Crossarm Insulator with a Large Diameter
Description:
The composite crossarm insulator differs greatly from the suspension insulator in structure and arrangement.
This study aims to determine the pollution flashover characteristics of composite crossarm insulators under different voltage grades.
Four types of AC composite crossarm insulators with diameters ranging from 100 mm to 450 mm are subjected to artificial pollution test, and then the effects of the surface hydrophobicity state of silicone rubber, core diameter, umbrella structure, arrangement, and insulation distance on the pollution flashover voltage of the composite crossarm insulators are analyzed.
Under the pollution grade 0.
2/1.
0 mg/cm2 and voltage grade from 66 kV to 1000 kV, if the silicone rubber surface changes from HC5 to HC6, the pollution flashover voltage of the composite crossarm insulator will increase by 13.
5% to 21.
0% compared with the hydrophilic surface.
If the core diameter changes from 100 mm to 300 mm, the pollution flashover voltage gradient decreases with the increase in core diameter; if the core diameter changes from 300 mm to 450 mm, the pollution flashover voltage gradient increases with core diameter.
Under the same insulation height and core diameter, the umbrella structure will have a certain impact on pollution flashover voltage by up to 1.
7% to 5.
4%.
Under the horizontal arrangement, the pollution flashover voltage can increase by 10.
5% to 12.
1% compared with that under the vertical arrangement.
Under the hydrophilic surface and weak hydrophobicity state, the pollution flashover voltage has a linear relationship with the insulation distance.
The above results can provide a reference for the structural design and optimization of the composite crossarm insulator.
Related Results
Flashover Performance and Process of Suspension Insulator Strings Artificially Covered with Snow
Flashover Performance and Process of Suspension Insulator Strings Artificially Covered with Snow
Snow accumulates on the surface of insulator string, causing a decrease in its electrical performance, seriously threatening the reliable operation of the power grid. Most previous...
Simulation of DC surface flashover of epoxy composites in compressed nitrogen
Simulation of DC surface flashover of epoxy composites in compressed nitrogen
To date, numerical simulation techniques for surface flashover are still under development. In this work, a DC surface flashover numerical simulation model is constructed based on ...
Investigation of Insulation Characteristics of GFRP Crossarm Subjected to Lightning Transient
Investigation of Insulation Characteristics of GFRP Crossarm Subjected to Lightning Transient
The advancement of material technology has contributed to the variation of high-performance composites with good electrical insulation and mechanical properties. Their usage in ele...
Surface charge accumulation and pre‐flashover characteristics induced by metal particles on the insulator surfaces of 1100 kV GILs under AC voltage
Surface charge accumulation and pre‐flashover characteristics induced by metal particles on the insulator surfaces of 1100 kV GILs under AC voltage
With the increase in the voltage and capacitance of gas‐insulated transmission lines (GILs), the insulation failure of GIL has attracted more and more attention. Further understand...
Influence of snow accretion on arc flashover gradient for various types of insulators
Influence of snow accretion on arc flashover gradient for various types of insulators
Atmospheric snow accretion along the insulators can eventually bridge adjacent shed spacing, which pose severe risks to the security of power networks. Aiming to investigate the in...
Effects of a Crossarm Brace Application on a 275 kV Fiberglass-Reinforced Polymer Crossarm Subjected to a Lightning Impulse
Effects of a Crossarm Brace Application on a 275 kV Fiberglass-Reinforced Polymer Crossarm Subjected to a Lightning Impulse
The crossarm is an important component of transmission towers, providing insulation for transmission lines at different voltage ratings. Recently, composite crossarms were widely u...
Influence of zinc oxide nanoparticles on flashover voltage of unsaturated polyester resin-based composites for electrical insulators
Influence of zinc oxide nanoparticles on flashover voltage of unsaturated polyester resin-based composites for electrical insulators
Introduction. Polyester-based composites are increasingly used in electrical applications for their insulation, mechanical, and thermal properties. Nanofillers have shown promise i...
NONLINEAR STATIC ANALYSIS OF COMPOSITE SHELLS USING ANALYSIS OF COMPOSITE SHELLS USING ANALYSIS OF COMPOSITE SHELLS USING ANALYSIS OF COMPOSITE SHELLS USING ANALYSIS OF COMPOSITE SHELLS USING ANALYSIS OF COMPOSITE SHELLS USING ANALYSIS OF COMPOSITE SHELLS
NONLINEAR STATIC ANALYSIS OF COMPOSITE SHELLS USING ANALYSIS OF COMPOSITE SHELLS USING ANALYSIS OF COMPOSITE SHELLS USING ANALYSIS OF COMPOSITE SHELLS USING ANALYSIS OF COMPOSITE SHELLS USING ANALYSIS OF COMPOSITE SHELLS USING ANALYSIS OF COMPOSITE SHELLS
This paper presents the results of the geometric nonlinear analysis of composite shell subjected to static load by using an edge-based smoothed finite elements (ES) and the mixed i...