Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Surface charge accumulation and pre‐flashover characteristics induced by metal particles on the insulator surfaces of 1100 kV GILs under AC voltage

View through CrossRef
With the increase in the voltage and capacitance of gas‐insulated transmission lines (GILs), the insulation failure of GIL has attracted more and more attention. Further understanding of the partial discharge (PD) and flashover characteristics of metal particles on the insulator surface, as well as the flashover mechanism, is necessary to reduce the failure rate and improve the reliability of the equipment. In this study, an ultra‐high voltage (UHV) AC insulator PD test and measurement system based on the cross‐reference pulse current (PC) and ultra‐high frequency (UHF) methods were established. The PD development and flashover characteristics of 5 mm‐long metal particles at different positions on the surface of a UHV AC insulator, as well as the surface charge accumulation, were studied. The results show that the discharge of millimetre‐scale metal particles on the insulator surface under PD test conditions is relatively low (generally lower than 2PC), and it is difficult to be detected by the conventional PC and UHF methods due to their insufficient sensitivity. Moreover, it is found that the weak PDs of the millimetre‐scale metal particles will result in a charge accumulation on the insulator surface under AC voltage, which eventually will lead to the insulator flashover. The PDs of the UHV AC insulator before flashover are generally small, which will make it difficult for online monitoring systems to give an effective alarm before flashover.
Title: Surface charge accumulation and pre‐flashover characteristics induced by metal particles on the insulator surfaces of 1100 kV GILs under AC voltage
Description:
With the increase in the voltage and capacitance of gas‐insulated transmission lines (GILs), the insulation failure of GIL has attracted more and more attention.
Further understanding of the partial discharge (PD) and flashover characteristics of metal particles on the insulator surface, as well as the flashover mechanism, is necessary to reduce the failure rate and improve the reliability of the equipment.
In this study, an ultra‐high voltage (UHV) AC insulator PD test and measurement system based on the cross‐reference pulse current (PC) and ultra‐high frequency (UHF) methods were established.
The PD development and flashover characteristics of 5 mm‐long metal particles at different positions on the surface of a UHV AC insulator, as well as the surface charge accumulation, were studied.
The results show that the discharge of millimetre‐scale metal particles on the insulator surface under PD test conditions is relatively low (generally lower than 2PC), and it is difficult to be detected by the conventional PC and UHF methods due to their insufficient sensitivity.
Moreover, it is found that the weak PDs of the millimetre‐scale metal particles will result in a charge accumulation on the insulator surface under AC voltage, which eventually will lead to the insulator flashover.
The PDs of the UHV AC insulator before flashover are generally small, which will make it difficult for online monitoring systems to give an effective alarm before flashover.

Related Results

Simulation of DC surface flashover of epoxy composites in compressed nitrogen
Simulation of DC surface flashover of epoxy composites in compressed nitrogen
To date, numerical simulation techniques for surface flashover are still under development. In this work, a DC surface flashover numerical simulation model is constructed based on ...
Flashover Performance and Process of Suspension Insulator Strings Artificially Covered with Snow
Flashover Performance and Process of Suspension Insulator Strings Artificially Covered with Snow
Snow accumulates on the surface of insulator string, causing a decrease in its electrical performance, seriously threatening the reliable operation of the power grid. Most previous...
Pollution Flashover Characteristics of Composite Crossarm Insulator with a Large Diameter
Pollution Flashover Characteristics of Composite Crossarm Insulator with a Large Diameter
The composite crossarm insulator differs greatly from the suspension insulator in structure and arrangement. This study aims to determine the pollution flashover characteristics of...
Influence of snow accretion on arc flashover gradient for various types of insulators
Influence of snow accretion on arc flashover gradient for various types of insulators
Atmospheric snow accretion along the insulators can eventually bridge adjacent shed spacing, which pose severe risks to the security of power networks. Aiming to investigate the in...
Influence of zinc oxide nanoparticles on flashover voltage of unsaturated polyester resin-based composites for electrical insulators
Influence of zinc oxide nanoparticles on flashover voltage of unsaturated polyester resin-based composites for electrical insulators
Introduction. Polyester-based composites are increasingly used in electrical applications for their insulation, mechanical, and thermal properties. Nanofillers have shown promise i...
Wettability’s Challenge to High-Voltage Insulators: Polyurethane as Preventive Coating
Wettability’s Challenge to High-Voltage Insulators: Polyurethane as Preventive Coating
The failure of a porcelain insulator on a transmission line is a crucial cause of power supply interruptions, leading to poor reliability and revenue loss. The insulator’s performa...
Progress in Surface Theory
Progress in Surface Theory
The workshop Progress in Surface Theory , organised by Uwe Abresch (Bochum), Josef Dorfmeister (München), and Masaaki Umehara (Osaka) was he...

Back to Top