Effect of Different Implant-Abutment Connection Materials on the Fracture Resistance of Zirconia Abutments
View through CrossRef
The aim of the present in vitro study was to assess the modes of failures under static load among titanium (Ti) and 1- and 2-piece zirconia abutments. The 1- and 2-piece zirconia abutment specimens were fabricated from prescanned Ti abutments. Twenty-one implant abutments and 21 implant replicas were equally divided into 3 groups as follows: (a) Group 1 (Titanium group); (b) Group 2 (1-piece zirconia abutment group); and (c) Group 3: 2-piece zirconia abutment group). A 250 000-cycle linear fatigue load ranging between 10 N and 210 N was applied to all specimens using an all-electric dynamic test instrument. The specimens were loaded until they fractured. In all groups, assessment of mode of fracture was done on visual assessment by a trained and calibrated investigator. Prior sample-size estimation was performed; and sample distribution was assessed using the Kolmogorov and Shapiro tests. Screw fracture (n = 7) and abutment bending at the apical part (n = 7) occurred in the Ti group. In the 1-piece zirconia group, screw and abutment fractures occurred in 7 and 7 cases, respectively. In the 2-piece zirconia screw fracture (n = 7) above the Ti zirconia junction (transgingival segment) and abutment fracture (n = 7) were determined as the failure modes. In vitro, the 1-piece zirconia abutments are more fracture resistant than titanium and 2-piece zirconia abutments. From a clinical perspective, further studies are needed to determine the minimum static load value required to induce fracture of the 1- and 2-piece zirconia abutments.
American Academy of Implant Dentistry
Title: Effect of Different Implant-Abutment Connection Materials on the Fracture Resistance of Zirconia Abutments
Description:
The aim of the present in vitro study was to assess the modes of failures under static load among titanium (Ti) and 1- and 2-piece zirconia abutments.
The 1- and 2-piece zirconia abutment specimens were fabricated from prescanned Ti abutments.
Twenty-one implant abutments and 21 implant replicas were equally divided into 3 groups as follows: (a) Group 1 (Titanium group); (b) Group 2 (1-piece zirconia abutment group); and (c) Group 3: 2-piece zirconia abutment group).
A 250 000-cycle linear fatigue load ranging between 10 N and 210 N was applied to all specimens using an all-electric dynamic test instrument.
The specimens were loaded until they fractured.
In all groups, assessment of mode of fracture was done on visual assessment by a trained and calibrated investigator.
Prior sample-size estimation was performed; and sample distribution was assessed using the Kolmogorov and Shapiro tests.
Screw fracture (n = 7) and abutment bending at the apical part (n = 7) occurred in the Ti group.
In the 1-piece zirconia group, screw and abutment fractures occurred in 7 and 7 cases, respectively.
In the 2-piece zirconia screw fracture (n = 7) above the Ti zirconia junction (transgingival segment) and abutment fracture (n = 7) were determined as the failure modes.
In vitro, the 1-piece zirconia abutments are more fracture resistant than titanium and 2-piece zirconia abutments.
From a clinical perspective, further studies are needed to determine the minimum static load value required to induce fracture of the 1- and 2-piece zirconia abutments.
Related Results
Dental Implant Abutments and Their Selection - A Review
Dental Implant Abutments and Their Selection - A Review
Dental implants have become the most promising and accepted prosthetic alternative to missing teeth. Innovative and technological advances in implant dentistry have improved the pe...
Fracture Resistance of Implant Abutments Following Abutment Alterations by Milling the Margins: An In Vitro Study
Fracture Resistance of Implant Abutments Following Abutment Alterations by Milling the Margins: An In Vitro Study
This in vitro study evaluated the effect of different levels of preparation of an implant abutment on its fracture resistance. The study evaluated abutments that incorporated a pla...
Implant‐Abutment Interface: Biomechanical Study of Flat Top versus Conical
Implant‐Abutment Interface: Biomechanical Study of Flat Top versus Conical
ABSTRACT Background: Overloading has been identified as a primary factor behind dental implant failure. The peak bone stresses normally appear in the marginal bone. The anchorage s...
Retention of Metal Crowns Luted to Implant Abutments of Two Different Diameters using Different Luting Agents
Retention of Metal Crowns Luted to Implant Abutments of Two Different Diameters using Different Luting Agents
ABSTRACT
Purpose
The desirable properties of a luting agent used for implant prostheses are adequate tensile strength for retention and at the same time render the crowns to be re...
The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study
The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study
This study aimed to compare the in vitro performance of anterior and posterior crowns with screw-retained polyetherketoneketone (PEKK) or zirconia abutments on two-piece zirconia i...
Peri‐Implant Esthetics in Focus: Comparing Anodized Titanium and Zirconium Dioxide Abutments in a Randomized Clinical Trial
Peri‐Implant Esthetics in Focus: Comparing Anodized Titanium and Zirconium Dioxide Abutments in a Randomized Clinical Trial
ABSTRACT
Objective
Achieving optimal esthetics remains challenging due to limited comparative evidence between pink‐anodi...
REUSE OF THE INTRAOSSEOUS PART OF THE DENTAL IMPLANT (THE CLINICAL CASE)
REUSE OF THE INTRAOSSEOUS PART OF THE DENTAL IMPLANT (THE CLINICAL CASE)
Introduction. Replacement of a small included defect in the frontal area with a fixed structure based on the implant is the optimal solution. It is not always required to remove th...
Stochastic Propagation of Discrete Fracture Networks
Stochastic Propagation of Discrete Fracture Networks
This reference is for an abstract only. A full paper was not submitted for this conference.
Abstract
Fractures are ubiquitous st...