Analysis of Transformer Loading Profile at 11/0.4 kV Distribution Voltage Network at Hospital Melaka
View through CrossRef
On distribution site, to offer customers with comfort in service, the dependability, stability, and residual lifetime of the transformer is important part to consider. The factors that affect the lifetime duration of a transformer are the ambient temperature, transformer oil temperature, and pattern of the consumed load. This paper discusses the load current demand profile of the transformers in three substations, Substation 1-3 (SS1-SS3) at Hospital Melaka. The load current demand profile is measured and recorded using Power Logger Fluke 175. The data logger is installed at main switch board feeder 1 and feeder 2 between 10 to 15 days. The normal loading and short time overloading (due to the contingency when the power supply is breakdown) of the transformers are analyzed in this paper. The finding shows that in normal loading conditions, each substation's transformer is loaded between 30% and 60% of its capacity, and its lifespan is anticipated to be more than ten years. Meanwhile, the short-time overloading of step-up distribution transformer at SS2 (TG1 and TG2) can be improved by raising the transformer size to 1600 kVA and 2000 kVA. This could prevent the transformer loading swing over its full capacity in accordance with the IEC 60076-7 guidelines.
Penerbit Universiti Teknikal Malaysia Melaka Press
Title: Analysis of Transformer Loading Profile at 11/0.4 kV Distribution Voltage Network at Hospital Melaka
Description:
On distribution site, to offer customers with comfort in service, the dependability, stability, and residual lifetime of the transformer is important part to consider.
The factors that affect the lifetime duration of a transformer are the ambient temperature, transformer oil temperature, and pattern of the consumed load.
This paper discusses the load current demand profile of the transformers in three substations, Substation 1-3 (SS1-SS3) at Hospital Melaka.
The load current demand profile is measured and recorded using Power Logger Fluke 175.
The data logger is installed at main switch board feeder 1 and feeder 2 between 10 to 15 days.
The normal loading and short time overloading (due to the contingency when the power supply is breakdown) of the transformers are analyzed in this paper.
The finding shows that in normal loading conditions, each substation's transformer is loaded between 30% and 60% of its capacity, and its lifespan is anticipated to be more than ten years.
Meanwhile, the short-time overloading of step-up distribution transformer at SS2 (TG1 and TG2) can be improved by raising the transformer size to 1600 kVA and 2000 kVA.
This could prevent the transformer loading swing over its full capacity in accordance with the IEC 60076-7 guidelines.
Related Results
TOURISM COMMUNICATION IN INDONESIA SOCIAL MEDIA
TOURISM COMMUNICATION IN INDONESIA SOCIAL MEDIA
Melaka is known to have historical values, even the beginning of the birth of Malaysia began in this country. Melaka is also known as the main maritime trade center in this region ...
High frequency modeling of power transformers under transients
High frequency modeling of power transformers under transients
This thesis presents the results related to high frequency modeling of power transformers. First, a 25kVA distribution transformer under lightning surges is tested in the laborator...
Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
Study of Transformer Lifetime Due to Loading Process on 20 KV Distribution Line
Study of Transformer Lifetime Due to Loading Process on 20 KV Distribution Line
Power transformer is very important in electric power system due to its function to raise or lower the voltage according to its designation. On the power side, the power transforme...
GEOPOLITIK MELAKA DAN PILIHAN POLITIK PENGUNDI DALAM PILIHAN RAYA DUN MELAKA 2021
GEOPOLITIK MELAKA DAN PILIHAN POLITIK PENGUNDI DALAM PILIHAN RAYA DUN MELAKA 2021
Politik Negeri Melaka terkenal sebagai kubu kuat BN sejak sebelum merdeka hingga PRU 2013. Namun pada PRU 2018, Melaka jatuh kepada parti pembangkang iaitu PH. 22 bulan selepas PH ...
TREASURE OF THE MELAKA MALAY SULTANATE: ANALYSIS OF HIDDEN TREASURE ON NANGKA ISLAND, MELAKA
TREASURE OF THE MELAKA MALAY SULTANATE: ANALYSIS OF HIDDEN TREASURE ON NANGKA ISLAND, MELAKA
The Melaka Sultanate rose to prominence as a dominant maritime power, controlling the vital Strait of Melaka and serving as a pivotal center of trade and commerce. The kingdom's pr...
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Abstract
Introduction
Hospitals are high-risk environments for infections. Despite the global recognition of these pathogens, few studies compare microorganisms from community-acqu...
Analisis Penggunaan Transformator Sisipan Untuk Mengatasi Rugi Tegangan dan Pembebanan Lebih
Analisis Penggunaan Transformator Sisipan Untuk Mengatasi Rugi Tegangan dan Pembebanan Lebih
On the JD267 distribution transformer with a capacity of 100 kVA at the Kalibaru feeder on the PT PLN (Persero) ULP Genteng experienced overloading at WBP (88.03%) and high voltag...