Javascript must be enabled to continue!
Modifications in corneal biomechanics and intraocular pressure after deep sclerectomy
View through CrossRef
PurposeTo compare preoperative and postoperative measurements of corneal biomechanical properties and intraocular pressure (IOP) using Goldmann applanation tonometry (GAT) and the ocular response analyzer (ORA, Reichert Inc, Depew, NY) in eyes undergoing deep sclerectomy with implant (DSCI).MethodsNinety eyes of 90 glaucomatous patients undergoing deep sclerectomy with SNOPER® implant and and 30 eyes of 30 normal subjects were included were included. Goldmann applanation IOP, central corneal thickness (CCT), and ORA measurements [corneal compensated IOP (IOPcc), Goldmann‐correlated IOP (IOPg), corneal resistance factor (CRF), and corneal hysteresis (CH)] were taken the day before deep sclerectomy with collagen implant and on days 1, 8, and 30 and three months after surgery.ResultsPreoperative CH and CRF values of the glaucomatous patients were statistically significantly lower than the values in normal subjects. Corneal hysteresis values increased significantly on day 1 after DSCI, and then showed a statistically significant decrease up to day 30. GAT IOP and all the other ORA parameters changed significantly on day 1 after DSCI, but there was no time effect variation up to 3 months. Only CH showed variations up to 3 months after surgery.ConclusionsCH statistically increased between preoperative and postoperative day 1 DSCI. On days 8 and 30, the change in CH values was statistically significant.
Title: Modifications in corneal biomechanics and intraocular pressure after deep sclerectomy
Description:
PurposeTo compare preoperative and postoperative measurements of corneal biomechanical properties and intraocular pressure (IOP) using Goldmann applanation tonometry (GAT) and the ocular response analyzer (ORA, Reichert Inc, Depew, NY) in eyes undergoing deep sclerectomy with implant (DSCI).
MethodsNinety eyes of 90 glaucomatous patients undergoing deep sclerectomy with SNOPER® implant and and 30 eyes of 30 normal subjects were included were included.
Goldmann applanation IOP, central corneal thickness (CCT), and ORA measurements [corneal compensated IOP (IOPcc), Goldmann‐correlated IOP (IOPg), corneal resistance factor (CRF), and corneal hysteresis (CH)] were taken the day before deep sclerectomy with collagen implant and on days 1, 8, and 30 and three months after surgery.
ResultsPreoperative CH and CRF values of the glaucomatous patients were statistically significantly lower than the values in normal subjects.
Corneal hysteresis values increased significantly on day 1 after DSCI, and then showed a statistically significant decrease up to day 30.
GAT IOP and all the other ORA parameters changed significantly on day 1 after DSCI, but there was no time effect variation up to 3 months.
Only CH showed variations up to 3 months after surgery.
ConclusionsCH statistically increased between preoperative and postoperative day 1 DSCI.
On days 8 and 30, the change in CH values was statistically significant.
Related Results
Corneal Biomechanical Changes in Third Trimester of Pregnancy
Corneal Biomechanical Changes in Third Trimester of Pregnancy
Background and Objectives: There is a clear evidence that pregnancy is associated with high production of sex hormones. During the first, second and third trimester of pregnancy, b...
Correlation Between Corneal Biomechanics and Anterior Segment Parameters in Healthy Saudi Females
Correlation Between Corneal Biomechanics and Anterior Segment Parameters in Healthy Saudi Females
Abstract
Background: The ocular response analyzer (ORA) can measure corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann correlated IOP (IOPg) and corneal com...
Evaluation of the effect of the corneal suture removal on corneal biomechanics with Corneal visualization Scheimpflug technology (Corvis ST) after penetrating keratoplasty (PKP)
Evaluation of the effect of the corneal suture removal on corneal biomechanics with Corneal visualization Scheimpflug technology (Corvis ST) after penetrating keratoplasty (PKP)
Background
The cornea is a part of the anterior segment of the eye, which plays an important role in the refraction of light rays on the retina. Cornea also maintains t...
Modification of Corneal Biomechanics and Intraocular Pressure Following Non-Penetrating Deep Sclerectomy
Modification of Corneal Biomechanics and Intraocular Pressure Following Non-Penetrating Deep Sclerectomy
Changes in the cornea can influence outcomes in patients with primary open-angle glaucoma (POAG). We aimed to evaluate the relevance of changes in corneal biomechanics and intraocu...
A retrospective analysis of outcomes of an optical reconstructive surgery combined with corneal transplantation dedicated to manage complications of inflammatory diseases of the anterior chamber of the ey
A retrospective analysis of outcomes of an optical reconstructive surgery combined with corneal transplantation dedicated to manage complications of inflammatory diseases of the anterior chamber of the ey
Background: full thickness corneal transplantation or penetrating keratoplasty (PK) is the only surgical method to manage outcomes of
inflammatory diseases of the anterior eye cham...
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
(English) The cornea is the outermost layer of the eye, essential for vision as it provides protection and contributes 80% of the eye’s refractive power. Its transparency and lack ...
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
BackgroundKeratoconus (KC) is an ectatic corneal disorder characterized by progressive corneal thinning with myopic astigmatism. Intrastromal corneal ring segments (ICRS) have been...
Alteration of corneal biomechanical properties in patients with dry eye disease
Alteration of corneal biomechanical properties in patients with dry eye disease
Purpose
To evaluate the association between symptoms and signs of dry eye diseases (DED) with corneal biomechanical parameters.
Methods
This cross-sectional study enrolled 81 par...