Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Modification of Corneal Biomechanics and Intraocular Pressure Following Non-Penetrating Deep Sclerectomy

View through CrossRef
Changes in the cornea can influence outcomes in patients with primary open-angle glaucoma (POAG). We aimed to evaluate the relevance of changes in corneal biomechanics and intraocular pressure (IOP) in patients undergoing non-penetrating deep sclerectomy (NPDS) with the Esnoper V2000 implant® (AJL Ophthalmic S.A., Gasteiz, Spain). We included 42 eyes of 42 patients with POAG scheduled for NPDS with the Esnoper V2000 implant. Biomechanical properties were measured by Ocular Response Analyzer® G3 (ORA; Reichert Inc., Depew, NY, USA). Corneal hysteresis (CH), corneal resistance factor (CRF), corneal compensated IOP (IOPcc), and Goldmann-correlated IOP (IOPg) were measured the day before surgery and on day 1, 7, and 30 and 2 and 3 months after surgery. CH initially increased, fell below the presurgical value at 30 days after the surgery, and increased again at 2 and 3 months. CRF, IOPcc, and IOPg decreased on the first day after surgery, then followed a trend of increasing but stayed below pre-surgery levels. All values reached statistical significance. While observed changes in corneal biomechanics after NPDS and Esnoper V2000 implant were significant, more studies are needed if we are to understand their influence on corneal biomechanics and their clinical relevance in POAG.
Title: Modification of Corneal Biomechanics and Intraocular Pressure Following Non-Penetrating Deep Sclerectomy
Description:
Changes in the cornea can influence outcomes in patients with primary open-angle glaucoma (POAG).
We aimed to evaluate the relevance of changes in corneal biomechanics and intraocular pressure (IOP) in patients undergoing non-penetrating deep sclerectomy (NPDS) with the Esnoper V2000 implant® (AJL Ophthalmic S.
A.
, Gasteiz, Spain).
We included 42 eyes of 42 patients with POAG scheduled for NPDS with the Esnoper V2000 implant.
Biomechanical properties were measured by Ocular Response Analyzer® G3 (ORA; Reichert Inc.
, Depew, NY, USA).
Corneal hysteresis (CH), corneal resistance factor (CRF), corneal compensated IOP (IOPcc), and Goldmann-correlated IOP (IOPg) were measured the day before surgery and on day 1, 7, and 30 and 2 and 3 months after surgery.
CH initially increased, fell below the presurgical value at 30 days after the surgery, and increased again at 2 and 3 months.
CRF, IOPcc, and IOPg decreased on the first day after surgery, then followed a trend of increasing but stayed below pre-surgery levels.
All values reached statistical significance.
While observed changes in corneal biomechanics after NPDS and Esnoper V2000 implant were significant, more studies are needed if we are to understand their influence on corneal biomechanics and their clinical relevance in POAG.

Related Results

Modifications in corneal biomechanics and intraocular pressure after deep sclerectomy
Modifications in corneal biomechanics and intraocular pressure after deep sclerectomy
PurposeTo compare preoperative and postoperative measurements of corneal biomechanical properties and intraocular pressure (IOP) using Goldmann applanation tonometry (GAT) and the ...
Corneal Biomechanical Changes in Third Trimester of Pregnancy
Corneal Biomechanical Changes in Third Trimester of Pregnancy
Background and Objectives: There is a clear evidence that pregnancy is associated with high production of sex hormones. During the first, second and third trimester of pregnancy, b...
Correlation Between Corneal Biomechanics and Anterior Segment Parameters in Healthy Saudi Females
Correlation Between Corneal Biomechanics and Anterior Segment Parameters in Healthy Saudi Females
Abstract Background: The ocular response analyzer (ORA) can measure corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann correlated IOP (IOPg) and corneal com...
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
(English) The cornea is the outermost layer of the eye, essential for vision as it provides protection and contributes 80% of the eye’s refractive power. Its transparency and lack ...
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
BackgroundKeratoconus (KC) is an ectatic corneal disorder characterized by progressive corneal thinning with myopic astigmatism. Intrastromal corneal ring segments (ICRS) have been...
Alteration of corneal biomechanical properties in patients with dry eye disease
Alteration of corneal biomechanical properties in patients with dry eye disease
Purpose To evaluate the association between symptoms and signs of dry eye diseases (DED) with corneal biomechanical parameters. Methods This cross-sectional study enrolled 81 par...

Back to Top