Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Alteration of corneal biomechanical properties in patients with dry eye disease

View through CrossRef
Purpose To evaluate the association between symptoms and signs of dry eye diseases (DED) with corneal biomechanical parameters. Methods This cross-sectional study enrolled 81 participants without history of ocular hypertension, glaucoma, keratoconus, corneal edema, contact lens use, diabetes, and ocular surgery. All participants were evaluated for symptoms and signs of DED using OSDI questionnaire, tear film break-up time (TBUT), conjunctival and corneal staining (NEI grading) and Schirmer test. Corneal biomechanical parameters were obtained using Corvis ST. Mixed-effects linear regression analysis was used to determine the association between symptoms and signs of DED with corneal biomechanical parameters. Difference in corneal biomechanical parameter between participants with low (Schirmer value ≤10 mm; LT group) and normal (Schirmer value >10mm; NT group) tear production was analyzed using ANCOVA test. Results The median OSDI scores, TBUT, conjunctival and corneal staining scores as well as Schirmer test were 13±16.5 (range; 0–77), 5.3±4.2 seconds (range; 1.3–11), 0±1 (range; 0–4), 0±2 (ranges; 0–9) and 16±14 mm (range; 0–45) respectively. Regression analysis adjusted with participants’ refraction, intraocular pressure, and central corneal thickness showed that OSDI had a negative association with highest concavity radius (P = 0.02). The association between DED signs and corneal biomechanical parameters were found between conjunctival staining scores with second applanation velocity (A2V, P = 0.04), corneal staining scores with second applanation length (A2L, P = 0.01), Schirmer test with first applanation time (A1T, P = 0.04) and first applanation velocity (P = 0.01). In subgroup analysis, there was no difference in corneal biomechanical parameters between participants with low and normal tear production (P>0.05). The associations were found between OSDI with time to highest concavity (P<0.01) and highest displacement of corneal apex (HC-DA, P = 0.04), conjunctival staining scores with A2L (P = 0.01) and A2V (P<0.01) in LT group, and Schirmer test with A1T (P = 0.02) and HC-DA (P = 0.03), corneal staining scores with A2L (P<0.01) in NT group. Conclusions According to in vivo observation with Corvis ST, patients with DED showed more compliant corneas. The increase in dry eye severity was associated with the worsening of corneal biomechanics in both patients with low and normal tear production.
Title: Alteration of corneal biomechanical properties in patients with dry eye disease
Description:
Purpose To evaluate the association between symptoms and signs of dry eye diseases (DED) with corneal biomechanical parameters.
Methods This cross-sectional study enrolled 81 participants without history of ocular hypertension, glaucoma, keratoconus, corneal edema, contact lens use, diabetes, and ocular surgery.
All participants were evaluated for symptoms and signs of DED using OSDI questionnaire, tear film break-up time (TBUT), conjunctival and corneal staining (NEI grading) and Schirmer test.
Corneal biomechanical parameters were obtained using Corvis ST.
Mixed-effects linear regression analysis was used to determine the association between symptoms and signs of DED with corneal biomechanical parameters.
Difference in corneal biomechanical parameter between participants with low (Schirmer value ≤10 mm; LT group) and normal (Schirmer value >10mm; NT group) tear production was analyzed using ANCOVA test.
Results The median OSDI scores, TBUT, conjunctival and corneal staining scores as well as Schirmer test were 13±16.
5 (range; 0–77), 5.
3±4.
2 seconds (range; 1.
3–11), 0±1 (range; 0–4), 0±2 (ranges; 0–9) and 16±14 mm (range; 0–45) respectively.
Regression analysis adjusted with participants’ refraction, intraocular pressure, and central corneal thickness showed that OSDI had a negative association with highest concavity radius (P = 0.
02).
The association between DED signs and corneal biomechanical parameters were found between conjunctival staining scores with second applanation velocity (A2V, P = 0.
04), corneal staining scores with second applanation length (A2L, P = 0.
01), Schirmer test with first applanation time (A1T, P = 0.
04) and first applanation velocity (P = 0.
01).
In subgroup analysis, there was no difference in corneal biomechanical parameters between participants with low and normal tear production (P>0.
05).
The associations were found between OSDI with time to highest concavity (P<0.
01) and highest displacement of corneal apex (HC-DA, P = 0.
04), conjunctival staining scores with A2L (P = 0.
01) and A2V (P<0.
01) in LT group, and Schirmer test with A1T (P = 0.
02) and HC-DA (P = 0.
03), corneal staining scores with A2L (P<0.
01) in NT group.
Conclusions According to in vivo observation with Corvis ST, patients with DED showed more compliant corneas.
The increase in dry eye severity was associated with the worsening of corneal biomechanics in both patients with low and normal tear production.

Related Results

Evaluation of preoperative dry eye in people undergoing corneal refractive surgery to correct myopia
Evaluation of preoperative dry eye in people undergoing corneal refractive surgery to correct myopia
AIM: To investigate the incidence of preoperative dry eye and related factors in patients undergoing corneal refractive surgery to correct myopia. METHODS: A total of 141 patients ...
<b>Corneal Biomechanical Integrity After Femtosecond Laser-Assisted Versus Manual Incisions in Cataract Surgery: A Systematic Review</b>
<b>Corneal Biomechanical Integrity After Femtosecond Laser-Assisted Versus Manual Incisions in Cataract Surgery: A Systematic Review</b>
Background: The integrity of the clear corneal incision is fundamental to safety, wound sealing, and refractive stability in cataract surgery. Although femtosecond laser-assisted c...
Psihološke odrednice sindroma suhog oka
Psihološke odrednice sindroma suhog oka
Introduction: Dry eye disease (DED) is a worldwide public health problem that may cause serious consequences for the patient's health. The etiology of the disease is multifactorial...
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
(English) The cornea is the outermost layer of the eye, essential for vision as it provides protection and contributes 80% of the eye’s refractive power. Its transparency and lack ...
Effects of TGFB1 and 17 B estradiol on corneal stiffness and thickness
Effects of TGFB1 and 17 B estradiol on corneal stiffness and thickness
Background: Impaired corneal stiffness and transparency are the hallmarks of some of the leading global causes of corneal blindness diseases, such as keratoconus (KCN) which is cha...
Clinical Profile and Corneal Complications of Staphylococcal Blepharitis at the Philippine General Hospital
Clinical Profile and Corneal Complications of Staphylococcal Blepharitis at the Philippine General Hospital
Objectives. Staphylococcal blepharitis is a common ocular condition that can cause significant visual morbidities due to corneal complications. This study described the clinical pr...
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
BackgroundKeratoconus (KC) is an ectatic corneal disorder characterized by progressive corneal thinning with myopic astigmatism. Intrastromal corneal ring segments (ICRS) have been...

Back to Top