Komparasi Kinerja AC Kendaraan dengan Menggunakan Refrigeran R-134a, dan R-290
View through CrossRef
The development of vapor compression refrigeration systems currently depends on the issue of environmental problems related to ozone layer depletion (ODP) and global warming potential (GWP). In addition to environmental issues, low energy use is also in the spotlight of researchers. To solve the problem of refrigeration development, natural refrigeration, especially hydrocarbons, is the focus of attention. Hydrocarbons are refrigerants that have excellent properties to be natural refrigerants. This study aims to compare the performance of refrigerant R-134a with R-290. The research used a standard vapor compression refrigeration system with a TEV-type expansion valve. The system performance is seen through compression, refrigeration effect, and COP with variations in compressor rotational speed of 1000 rpm, 1500 rpm, and 2000 rpm. The results showed that the compression work, refrigeration effect, and coefficient of performance (COP) of R-290 had a more excellent value. R-290 produces the highest compression work at a 2000 rpm compressor speed of 33.34 kJ/kg for the refrigeration effect at 1000 rpm of 353.33 kJ/kg and COP at 1500 rpm 12.32.
Universitas Muhammadiyah Magelang
Title: Komparasi Kinerja AC Kendaraan dengan Menggunakan Refrigeran R-134a, dan R-290
Description:
The development of vapor compression refrigeration systems currently depends on the issue of environmental problems related to ozone layer depletion (ODP) and global warming potential (GWP).
In addition to environmental issues, low energy use is also in the spotlight of researchers.
To solve the problem of refrigeration development, natural refrigeration, especially hydrocarbons, is the focus of attention.
Hydrocarbons are refrigerants that have excellent properties to be natural refrigerants.
This study aims to compare the performance of refrigerant R-134a with R-290.
The research used a standard vapor compression refrigeration system with a TEV-type expansion valve.
The system performance is seen through compression, refrigeration effect, and COP with variations in compressor rotational speed of 1000 rpm, 1500 rpm, and 2000 rpm.
The results showed that the compression work, refrigeration effect, and coefficient of performance (COP) of R-290 had a more excellent value.
R-290 produces the highest compression work at a 2000 rpm compressor speed of 33.
34 kJ/kg for the refrigeration effect at 1000 rpm of 353.
33 kJ/kg and COP at 1500 rpm 12.
32.
Related Results
PERAN TATA KELOLA PERUSAHAAN DALAM MEMODERASI PENGARUH IMPLEMANTASI GREEN ACCOUNTING, CORPORATE SOCIAL RESPONSIBILITY DAN FIRM SIZE TERHADAP KINERJA KEUANGAN
PERAN TATA KELOLA PERUSAHAAN DALAM MEMODERASI PENGARUH IMPLEMANTASI GREEN ACCOUNTING, CORPORATE SOCIAL RESPONSIBILITY DAN FIRM SIZE TERHADAP KINERJA KEUANGAN
This study examines the role of corporate governance in moderating the influence of green accounting disclosure, corporate social responsibility (CSR), and firm size on the financi...
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review Anna Tri Wahyuni1), Masfuri2), Liya Arista3)1,2,3 Fakultas Ilmu Keperawatan Univers...
NILAI ESRTIKA MODIFIKASI VESPA ROSOK BONDOWOSO
NILAI ESRTIKA MODIFIKASI VESPA ROSOK BONDOWOSO
NILAI ESTETIKA VESPA MODIFIKASI KOMUNITAS VESPA BONDOWOSO Syarief Abdurahman Arrahim1, I Wayan Sudiarta2, I Gst Ngr. Sura Ardana31,2,3Program Studi Pendidikan Seni RupaFakultas Ba...
KEBERADAAN KENDARAAN RODA TIGA SEBAGAI ODONG-ODONG DI KABUPATEN SUMENEP MENURUT HUKUM POSITIF
KEBERADAAN KENDARAAN RODA TIGA SEBAGAI ODONG-ODONG DI KABUPATEN SUMENEP MENURUT HUKUM POSITIF
Kendaraan atau angkutan adalah wahana alat transportasi, baik yang digerakkan oleh mesin maupun oleh mahluk hidup. Kendaraan terdiri dari kendaraan bermotor dan kendaraan tidak ber...
Sistem Antrian Kendaraan Angkutan Barang pada Unit Pelaksana Penimbangan Kendaraan Bermotor Kayumalue
Sistem Antrian Kendaraan Angkutan Barang pada Unit Pelaksana Penimbangan Kendaraan Bermotor Kayumalue
Abstract. The high arrival flow of freight vehicles at Kayumalue Motor Vehicle Weighing Implementation Unit at certain times causes queues. The purpose of this study was to determi...
Systemic Exposure of Budesonide/Glycopyrrolate/Formoterol Fumarate With Hydrofluoroolefin-1234ze Versus Hydrofluoroalkane-134a Propellants Administered Via Metered-Dose Inhaler With a Spacer in Healthy Adults
Systemic Exposure of Budesonide/Glycopyrrolate/Formoterol Fumarate With Hydrofluoroolefin-1234ze Versus Hydrofluoroalkane-134a Propellants Administered Via Metered-Dose Inhaler With a Spacer in Healthy Adults
Abstract
Rationale: Hydrofluoroolefin-1234ze (HFO-1234ze) propellant is in development for pressurized metered-dose inhalers (pMDIs), having >99.9% lower g...
Bioequivalence of budesonide/glycopyrrolate/formoterol fumarate with a next-generation propellant versus hydrofluoroalkane-134a in healthy adults: phase I, randomized, double-blind, single-dose, partial-replicate, three-way cross-over lung exposure and to
Bioequivalence of budesonide/glycopyrrolate/formoterol fumarate with a next-generation propellant versus hydrofluoroalkane-134a in healthy adults: phase I, randomized, double-blind, single-dose, partial-replicate, three-way cross-over lung exposure and to
Background:
Hydrofluoroolefin-1234ze (HFO-1234ze) is a next-generation propellant with 99.9% lower global warming potential (GWP) than hydrofluoroalkane-134a (H...