Javascript must be enabled to continue!
A Comparative Evaluation of Space Closure Rate Between Newer Generation Ceramic Brackets and Conventional Straight Wire Appliances
View through CrossRef
Background: With the emerging concept of aesthetics in orthodontics, ceramic brackets play a major role especially in the anterior region of the dental arch. However, the duration of the orthodontic treatment is one of the most important issues in treating patients with ceramic brackets. Objectives: This study is conducted to compare space closing rate between conventional MBT and Symetri ClearTM bracket systems. Methods: This study is comprised of 18 subjects who were equally separated into two groups. The first group was treated with conventional MBT pre-adjusted bracket and the second group with Symetri ClearTM brackets. Space closure was performed via 0.019 × 0.025 inch stainless steel wires using 9-mm nickel-titanium Sentalloy coil springs with a constant force of 150 g. The distance between the distal of the first molar buccal tube and the mesial of the canine bracket was measured by a digital caliper. The difference of the first and last values was determined to assess the sheer quantity of space closure. The value was then divided by the number of months during which the space closure was carried out to examine the ratio of space closure in mm per month. For the statistical analysis we used paired t test as well as independent t test and the P-value > 0.05 was deemed significant. Results: The MBT group showed a 0.85 mm/appointment retraction rate while the Symetri ClearTM bracket group had a 0.83 mm/appointment retraction rate. The difference in space closing between MBT and Symetri ClearTM groups was not statistically and clinically significant (P-value > 0.05). Conclusions: As the rate of space closure was almost similar in the two types of brackets, we can use Symetri ClearTM brackets instead of MBT brackets without any concern about the duration of treatment and use the esthetic benefits of these brackets simultaneously.
Title: A Comparative Evaluation of Space Closure Rate Between Newer Generation Ceramic Brackets and Conventional Straight Wire Appliances
Description:
Background: With the emerging concept of aesthetics in orthodontics, ceramic brackets play a major role especially in the anterior region of the dental arch.
However, the duration of the orthodontic treatment is one of the most important issues in treating patients with ceramic brackets.
Objectives: This study is conducted to compare space closing rate between conventional MBT and Symetri ClearTM bracket systems.
Methods: This study is comprised of 18 subjects who were equally separated into two groups.
The first group was treated with conventional MBT pre-adjusted bracket and the second group with Symetri ClearTM brackets.
Space closure was performed via 0.
019 × 0.
025 inch stainless steel wires using 9-mm nickel-titanium Sentalloy coil springs with a constant force of 150 g.
The distance between the distal of the first molar buccal tube and the mesial of the canine bracket was measured by a digital caliper.
The difference of the first and last values was determined to assess the sheer quantity of space closure.
The value was then divided by the number of months during which the space closure was carried out to examine the ratio of space closure in mm per month.
For the statistical analysis we used paired t test as well as independent t test and the P-value > 0.
05 was deemed significant.
Results: The MBT group showed a 0.
85 mm/appointment retraction rate while the Symetri ClearTM bracket group had a 0.
83 mm/appointment retraction rate.
The difference in space closing between MBT and Symetri ClearTM groups was not statistically and clinically significant (P-value > 0.
05).
Conclusions: As the rate of space closure was almost similar in the two types of brackets, we can use Symetri ClearTM brackets instead of MBT brackets without any concern about the duration of treatment and use the esthetic benefits of these brackets simultaneously.
Related Results
A Comparative Evaluation of Frictional Resistance of Conventional, Teflon and Epoxy Coated Stainless Steel Archwires in Metal, Ceramic Brackets – An In vitro Study
A Comparative Evaluation of Frictional Resistance of Conventional, Teflon and Epoxy Coated Stainless Steel Archwires in Metal, Ceramic Brackets – An In vitro Study
Aim and Objectives: To evaluate the frictional resistance of Conventional, Teflon, and Epoxy coated stainless steel archwires in Metal, Ceramic brackets.
Materials and Method...
Comparative Evaluation of Frictional Resistance Between Conventional, Self-Ligating, and Ceramic Brackets Using Different Archwire Materials: An In Vitro Study
Comparative Evaluation of Frictional Resistance Between Conventional, Self-Ligating, and Ceramic Brackets Using Different Archwire Materials: An In Vitro Study
Background Frictional resistance at the bracket-archwire interface is a critical determinant of force delivery during sliding mechanics. Bracket design, slot material, ligation met...
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Comparison of active self-ligating brackets and conventional pre-adjusted brackets
Comparison of active self-ligating brackets and conventional pre-adjusted brackets
Abstract
Background
Active self-ligating brackets may be more efficient than conventional pre-adjusted brackets.
...
Static frictional resistances of polycrystalline ceramic brackets with conventional slots, glazed slots and metal slot inserts
Static frictional resistances of polycrystalline ceramic brackets with conventional slots, glazed slots and metal slot inserts
Abstract
Aims
To compare the static frictional resistance of ceramic brackets with a conventional slot (Allure), a glazed...
175 Sternal Closure with Single Compared to Double or Figure-Of-8 Wires in Obese Patients Post Cardiac Surgery: A Systematic Review and Meta-Analysis
175 Sternal Closure with Single Compared to Double or Figure-Of-8 Wires in Obese Patients Post Cardiac Surgery: A Systematic Review and Meta-Analysis
Abstract
Aim
Sternal instability and wound infections are a major cause of morbidity following cardiac surgery, which is further...
Evaluation of the frictional resistance between different bracket types, archwires and ligation materials: An in-vitro study
Evaluation of the frictional resistance between different bracket types, archwires and ligation materials: An in-vitro study
In orthodontic treatment, brackets need to slide along the archwire to allow for alignment of the teeth. The lesser the friction between the bracket and the archwire, the easier it...
The periodontal status of removable appliances vs fixed appliances
The periodontal status of removable appliances vs fixed appliances
Abstract
Background:
Although several researchers have analyzed the dental identity of patients experience with corrective methods using fixed an...

