Javascript must be enabled to continue!
Static frictional resistances of polycrystalline ceramic brackets with conventional slots, glazed slots and metal slot inserts
View through CrossRef
Abstract
Aims
To compare the static frictional resistance of ceramic brackets with a conventional slot (Allure), a glazed slot (Mystique) and a metal slot insert (Clarity).
Method
Twenty five brackets of each type, with slot size 0.022 x 0.028 inch and Roth prescription were tested by sliding against straight lengths of 0.019 x 0.025 inch rectangular stainless steel wire. During the tests the brackets and wire were lubricated with artificial saliva. Static frictional forces at three different simulated binding angulations (0, 5 and 10 degrees) were measured for each type of bracket.
Results
At each of the angulations tested, the Clarity brackets produced the lowest static frictional resistance. At 0 degree angulation (below the critical angle for binding) the Allure brackets produced the greatest friction. The difference in friction between the Clarity and Mystique brackets was not statistically significant. As the angulations were increased to 5 degrees the Allure brackets again produced the greatest frictional resistance, although this was not significantly higher than the Mystique brackets. The Mystique brackets produced the greatest frictional resistance at 10 degrees, but again there was no statistical difference from the Allure brackets.
Conclusions
A glazed slot ceramic bracket demonstrates low frictional resistance at non-binding angulations and compares favourably with a metal slot ceramic bracket. Increasing angulations through 5 to 10 degrees of simulated binding results in high levels of static frictional resistance such that the bracket behaves more like a conventional polycrystalline ceramic bracket.
Title: Static frictional resistances of polycrystalline ceramic brackets with conventional slots, glazed slots and metal slot inserts
Description:
Abstract
Aims
To compare the static frictional resistance of ceramic brackets with a conventional slot (Allure), a glazed slot (Mystique) and a metal slot insert (Clarity).
Method
Twenty five brackets of each type, with slot size 0.
022 x 0.
028 inch and Roth prescription were tested by sliding against straight lengths of 0.
019 x 0.
025 inch rectangular stainless steel wire.
During the tests the brackets and wire were lubricated with artificial saliva.
Static frictional forces at three different simulated binding angulations (0, 5 and 10 degrees) were measured for each type of bracket.
Results
At each of the angulations tested, the Clarity brackets produced the lowest static frictional resistance.
At 0 degree angulation (below the critical angle for binding) the Allure brackets produced the greatest friction.
The difference in friction between the Clarity and Mystique brackets was not statistically significant.
As the angulations were increased to 5 degrees the Allure brackets again produced the greatest frictional resistance, although this was not significantly higher than the Mystique brackets.
The Mystique brackets produced the greatest frictional resistance at 10 degrees, but again there was no statistical difference from the Allure brackets.
Conclusions
A glazed slot ceramic bracket demonstrates low frictional resistance at non-binding angulations and compares favourably with a metal slot ceramic bracket.
Increasing angulations through 5 to 10 degrees of simulated binding results in high levels of static frictional resistance such that the bracket behaves more like a conventional polycrystalline ceramic bracket.
Related Results
Evaluation of the frictional resistance between different bracket types, archwires and ligation materials: An in-vitro study
Evaluation of the frictional resistance between different bracket types, archwires and ligation materials: An in-vitro study
In orthodontic treatment, brackets need to slide along the archwire to allow for alignment of the teeth. The lesser the friction between the bracket and the archwire, the easier it...
A Comparative Evaluation of Frictional Resistance of Conventional, Teflon and Epoxy Coated Stainless Steel Archwires in Metal, Ceramic Brackets – An In vitro Study
A Comparative Evaluation of Frictional Resistance of Conventional, Teflon and Epoxy Coated Stainless Steel Archwires in Metal, Ceramic Brackets – An In vitro Study
Aim and Objectives: To evaluate the frictional resistance of Conventional, Teflon, and Epoxy coated stainless steel archwires in Metal, Ceramic brackets.
Materials and Method...
Comparison of active self-ligating brackets and conventional pre-adjusted brackets
Comparison of active self-ligating brackets and conventional pre-adjusted brackets
Abstract
Background
Active self-ligating brackets may be more efficient than conventional pre-adjusted brackets.
...
Passive self-ligating metal brackets: evaluation of torque and slot measurements
Passive self-ligating metal brackets: evaluation of torque and slot measurements
New orthodontic bracket designs have been regularly developed. Their clinical performance depends on reliability of measures, among other factors. Objective: The aim of this study ...
A new elastic slot system and V-wire mechanics
A new elastic slot system and V-wire mechanics
ABSTRACTObjective:To biomechanically test a new elastic slot system and V-wire mechanics.Materials and Methods:Conventional twin and self-ligating brackets and the new elastodynami...
Ceramic inserts do not generally improve resin composite margins
Ceramic inserts do not generally improve resin composite margins
summary Ceramic inserts are reported to possibly reduce polymerization shrinkage for posterior resin composite fillings. The aim of the present investigation was to evaluate the e...
The effects of silver coating on friction coefficient and shear bond strength of steel orthodontic brackets
The effects of silver coating on friction coefficient and shear bond strength of steel orthodontic brackets
SummaryAims of the present study was to measure frictional resistance between silver coated brackets and different types of arch wires, and shear bond strength of these brackets to...
Comparative Study of Shear Bond Strength of Recycled Brackets using different Recycling Techniques – An in vitro study
Comparative Study of Shear Bond Strength of Recycled Brackets using different Recycling Techniques – An in vitro study
Introduction: The debonding of brackets is common in orthodontic practice. It may be due to bond failure or as a need for bracket repositioning. Typically practitioners shall disca...

