The effects of silver coating on friction coefficient and shear bond strength of steel orthodontic brackets

View through CrossRef
SummaryAims of the present study was to measure frictional resistance between silver coated brackets and different types of arch wires, and shear bond strength of these brackets to the tooth. In an experimental clinical research 28 orthodontic brackets (standard, 22 slots) were coated with silver ions using electroplate method. Six brackets (coated: 3, uncoated: 3) were evaluated with Scanning Electron Microscopy and Atomic Force Microscopy. The amount of friction in 15 coated brackets was measured with three different kinds of arch wires (0.019 × 0.025‐in stainless steel [SS], 0.018‐in stainless steel [SS], 0.018‐in Nickel‐Titanium [Ni‐Ti]) and compared with 15 uncoated steel brackets. In addition, shear bond strength values were compared between 10 brackets with silver coating and 10 regular brackets. Universal testing machine was used to measure shear bond strength and the amount of friction between the wires and brackets. SPSS 18 was used for data analysis with t‐test. SEM and AFM results showed deposition of a uniform layer of silver, measuring 8–10 μm in thickness on bracket surfaces. Silver coating led to higher frictional forces in all the three types of arch wires, which was statistically significant in 0.019 × 0.025‐in SS and 0.018‐in Ni‐Ti, but it did not change the shear bond strength significantly. Silver coating with electroplating method did not affect the bond strength of the bracket to enamel; in addition, it was not an effective method for decreasing friction in sliding mechanics. SCANNING 37:294–299, 2015. © 2015 Wiley Periodicals, Inc.
Title: The effects of silver coating on friction coefficient and shear bond strength of steel orthodontic brackets
Description:
SummaryAims of the present study was to measure frictional resistance between silver coated brackets and different types of arch wires, and shear bond strength of these brackets to the tooth.
In an experimental clinical research 28 orthodontic brackets (standard, 22 slots) were coated with silver ions using electroplate method.
Six brackets (coated: 3, uncoated: 3) were evaluated with Scanning Electron Microscopy and Atomic Force Microscopy.
The amount of friction in 15 coated brackets was measured with three different kinds of arch wires (0.
019 × 0.
025‐in stainless steel [SS], 0.
018‐in stainless steel [SS], 0.
018‐in Nickel‐Titanium [Ni‐Ti]) and compared with 15 uncoated steel brackets.
In addition, shear bond strength values were compared between 10 brackets with silver coating and 10 regular brackets.
Universal testing machine was used to measure shear bond strength and the amount of friction between the wires and brackets.
SPSS 18 was used for data analysis with t‐test.
SEM and AFM results showed deposition of a uniform layer of silver, measuring 8–10 μm in thickness on bracket surfaces.
Silver coating led to higher frictional forces in all the three types of arch wires, which was statistically significant in 0.
019 × 0.
025‐in SS and 0.
018‐in Ni‐Ti, but it did not change the shear bond strength significantly.
Silver coating with electroplating method did not affect the bond strength of the bracket to enamel; in addition, it was not an effective method for decreasing friction in sliding mechanics.
SCANNING 37:294–299, 2015.
© 2015 Wiley Periodicals, Inc.

Related Results

Comparative Study of Shear Bond Strength of Recycled Brackets using different Recycling Techniques – An in vitro study
Comparative Study of Shear Bond Strength of Recycled Brackets using different Recycling Techniques – An in vitro study
Introduction: The debonding of brackets is common in orthodontic practice. It may be due to bond failure or as a need for bracket repositioning. Typically practitioners shall disca...
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
Comparison of the Initial Repeated Bond Strength among Three Orthodontic Bonding Systems
Comparison of the Initial Repeated Bond Strength among Three Orthodontic Bonding Systems
One of the problems that often occurred during orthodontic treatment is bracket failure. This is usually the result either of the patient’s accidentally, applying inappropriate for...
Comparison of active self-ligating brackets and conventional pre-adjusted brackets
Comparison of active self-ligating brackets and conventional pre-adjusted brackets
Abstract Background Active self-ligating brackets may be more efficient than conventional pre-adjusted brackets. ...
A 3D-Printed Crown Integrated with 3D-Printed Orthodontic Brackets: A Novel One-Unit Printing Technique
A 3D-Printed Crown Integrated with 3D-Printed Orthodontic Brackets: A Novel One-Unit Printing Technique
This study aimed to present a new application of 3D printing technology for crowns integrated with orthodontic brackets as one unit and to assess the strength of the bonded groups ...
Coating Processes of Pharmaceutical Applicability: A Glimpse
Coating Processes of Pharmaceutical Applicability: A Glimpse
Presentation of manuscript is aiming to furnish glimpse on coating processes. Coating is process of snugly covering substrate surface with coating materials (CoM). In due course co...
Optimization of magnetoelectricity in thickness shear mode LiNbO3/magnetostrictive laminated composite
Optimization of magnetoelectricity in thickness shear mode LiNbO3/magnetostrictive laminated composite
Magnetoelectric (ME) composites have recently attracted much attention and triggered a great number of research activities, owing to their potential applications in sensors and tra...