Javascript must be enabled to continue!
Comparison of the Initial Repeated Bond Strength among Three Orthodontic Bonding Systems
View through CrossRef
One of the problems that often occurred during orthodontic treatment is bracket failure. This is usually the result either of the patient’s accidentally, applying inappropriate forces to the bracket or of a poor bonding technique. Thus, a significant number of teeth have to be rebonded in an orthodontic practice. Objective: The aim of this study was to evaluate the in vitro initial repeated shear bond strength of the three adhesive systems at two and five minutes after placement of a bracket. Materials and Methods: The three bonding agent adhesives are System1+, Rely-a-bond, Unite. Two hundred and forty human premolar teeth were divided into two groups, a control and an experimental group. Each group was further divided into three subgroups for bonding brackets with the three different adhesives. Only the teeth in the experimental group were sequentially bonded and debonded two times with the same adhesive. The teeth in control and experimental groups were tested for shear bond strength (at two and five minutes after the bracket was bonded) with an Instron testing machine. Results: The studies were found that : (1) there were differences between the shear bond strength of each adhesive in the control and experimental group. Unite had the highest shear bond strength followed by Rely-a-bond and System1+ at two minutes and five minutes, (2) the experiment group ( rebonded brackets) had higher shear bond strength than control group and Unite had in significant difference (p<0.05) of initial repeated bond strength with System1+ and Rely-a-bond at two minutes and five minutes and (3) there were mostly significant difference (p<0.05) between repeated shear bond strength at two minutes and repeated shear bond strength at five minutes. Conclusion: There were significant difference of the initial repeated shear bond strength of each adhesive. The orthodontists should be aware of applying force for tooth movement into the repeated bonding brackets.
Trans Tech Publications, Ltd.
Title: Comparison of the Initial Repeated Bond Strength among Three Orthodontic Bonding Systems
Description:
One of the problems that often occurred during orthodontic treatment is bracket failure.
This is usually the result either of the patient’s accidentally, applying inappropriate forces to the bracket or of a poor bonding technique.
Thus, a significant number of teeth have to be rebonded in an orthodontic practice.
Objective: The aim of this study was to evaluate the in vitro initial repeated shear bond strength of the three adhesive systems at two and five minutes after placement of a bracket.
Materials and Methods: The three bonding agent adhesives are System1+, Rely-a-bond, Unite.
Two hundred and forty human premolar teeth were divided into two groups, a control and an experimental group.
Each group was further divided into three subgroups for bonding brackets with the three different adhesives.
Only the teeth in the experimental group were sequentially bonded and debonded two times with the same adhesive.
The teeth in control and experimental groups were tested for shear bond strength (at two and five minutes after the bracket was bonded) with an Instron testing machine.
Results: The studies were found that : (1) there were differences between the shear bond strength of each adhesive in the control and experimental group.
Unite had the highest shear bond strength followed by Rely-a-bond and System1+ at two minutes and five minutes, (2) the experiment group ( rebonded brackets) had higher shear bond strength than control group and Unite had in significant difference (p<0.
05) of initial repeated bond strength with System1+ and Rely-a-bond at two minutes and five minutes and (3) there were mostly significant difference (p<0.
05) between repeated shear bond strength at two minutes and repeated shear bond strength at five minutes.
Conclusion: There were significant difference of the initial repeated shear bond strength of each adhesive.
The orthodontists should be aware of applying force for tooth movement into the repeated bonding brackets.
Related Results
Surface Activated Bonding -from the Standard SAB to Modified SAB
Surface Activated Bonding -from the Standard SAB to Modified SAB
The surface activated bonding (SAB) was proposedin thelate 1980’s for bonding of metal to metal and to ceramics at room temperature. The standard SAB method is based on surface act...
2 mils Au wire interchip wedge bond cratering study
2 mils Au wire interchip wedge bond cratering study
Au wire thermosonic wedge bonding is applied for die to die interconnect on accelerometer device. With the fragile bond pad structure of MEMS device, bond pad cratering or bond pad...
Evaluation of Four Different Adhesive Systems’ Bonding Strength Between Superficial and Deep Dentin
Evaluation of Four Different Adhesive Systems’ Bonding Strength Between Superficial and Deep Dentin
The success of adhesive restorations largely depends on the optimal bond strength between the tooth structure and the restorative material. The aim of this study was to evaluate th...
Accuracy Evaluation of Indirect Bonding Techniques for Clear Aligner Attachments Using 3D-Printed Models: An In Silico and Physical Model-Based Study
Accuracy Evaluation of Indirect Bonding Techniques for Clear Aligner Attachments Using 3D-Printed Models: An In Silico and Physical Model-Based Study
An inaccurate bonding procedure of the attachments related to clear aligner systems could influence the predictability of tooth movement The aim of this study was to compare the po...
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
Comparative Study of Shear Bond Strength of Recycled Brackets using different Recycling Techniques – An in vitro study
Comparative Study of Shear Bond Strength of Recycled Brackets using different Recycling Techniques – An in vitro study
Introduction: The debonding of brackets is common in orthodontic practice. It may be due to bond failure or as a need for bracket repositioning. Typically practitioners shall disca...
The chemical bond properties and ferroelectricity studies of SrBi4Ti4O15
The chemical bond properties and ferroelectricity studies of SrBi4Ti4O15
Spontaneous polarization as the most immediate parameter in ferroelectricity is always an emphasis in ferroelectric research. Some ferroelectric microscopic theory such as Berry-ph...
Collective D2W Hybrid Bonding for 3D SIC and Heterogeneous Integration
Collective D2W Hybrid Bonding for 3D SIC and Heterogeneous Integration
Heterogeneous integration describes the coalescence of multiple developments of the past years. On the one hand, 3D integration technologies have been emerged and are widely availa...

