Abstract Aim Sternal instability and wound infections are a major cause of morbidity following cardiac surgery, which is further amplified in high-risk patients that include diabetics and patients with high BMI. We compare the different outcomes of different sternal wire closure techniques following median sternotomy for cardiac surgery in obese patients Method A comprehensive electronic literature search was undertaken according to PRISMA guidelines from inception to July 2020 to identify all published data comparing single wire sternal closure to either double wire or figure-of-8 techniques following median sternotomy for cardiac surgery in obese patients, defined as a BMI ≥ 30. Results Eight studies met the final inclusion criteria; single wire versus double wire sternal closure (n = 2) and single wire versus figure-of-8 wire closure (n = 6). Higher rate of sternal instability was noted in single wire vs double wire closure (22/150 (14.7%) patients vs 6/150 (4%) patients, p = 0.003, OR 0.25 [95% CI 0.10-0.63]). Similarly, sternal instability was higher in single wire vs figure-of-8 wire closure technique (33/2422 (1.3%) vs 11/8035 (0.1%), p = 0.04 OR 0.30 [95% CI, 0.09-0.96]) respectively. Conclusions There is benefit in the use of either double or figure-of-8 sternal wire closure techniques over single wire closure in terms of sternal instability. However, as the studies were limited, larger scale comparative studies are required to provide a solid evidence base for choosing the optimal sternal closure technique in this high-risk group of patients.
Title: 175 Sternal Closure with Single Compared to Double or Figure-Of-8 Wires in Obese Patients Post Cardiac Surgery: A Systematic Review and Meta-Analysis
Description:
Abstract Aim Sternal instability and wound infections are a major cause of morbidity following cardiac surgery, which is further amplified in high-risk patients that include diabetics and patients with high BMI.
We compare the different outcomes of different sternal wire closure techniques following median sternotomy for cardiac surgery in obese patients Method A comprehensive electronic literature search was undertaken according to PRISMA guidelines from inception to July 2020 to identify all published data comparing single wire sternal closure to either double wire or figure-of-8 techniques following median sternotomy for cardiac surgery in obese patients, defined as a BMI ≥ 30.
Results Eight studies met the final inclusion criteria; single wire versus double wire sternal closure (n = 2) and single wire versus figure-of-8 wire closure (n = 6).
Higher rate of sternal instability was noted in single wire vs double wire closure (22/150 (14.
7%) patients vs 6/150 (4%) patients, p = 0.
003, OR 0.
25 [95% CI 0.
10-0.
63]).
Similarly, sternal instability was higher in single wire vs figure-of-8 wire closure technique (33/2422 (1.
3%) vs 11/8035 (0.
1%), p = 0.
04 OR 0.
30 [95% CI, 0.
09-0.
96]) respectively.
Conclusions There is benefit in the use of either double or figure-of-8 sternal wire closure techniques over single wire closure in terms of sternal instability.
However, as the studies were limited, larger scale comparative studies are required to provide a solid evidence base for choosing the optimal sternal closure technique in this high-risk group of patients.

Related Results

Improving Sternal Closure Outcomes in Cardiac Surgery: Polyethylene Suture Tapes vs. Steel Wires
Improving Sternal Closure Outcomes in Cardiac Surgery: Polyethylene Suture Tapes vs. Steel Wires
Background: Steel wires are often inadequate for sternal closure for patients at high risk of sternal complications. This study compares a novel sternal closure system to conventio...
Interlocking Multi-Twisted Wires Versus Interrupted Simple Sternal Wires for Closure of Median Sternotomy
Interlocking Multi-Twisted Wires Versus Interrupted Simple Sternal Wires for Closure of Median Sternotomy
Background: Although closure of a sternotomy incision is usually a simple procedure, failure to do so (sternal dehiscence) is a serious complication and is an independent factor th...
Application of new rigid sternal plates and prediction of sternal dehiscence in high-risk patients
Application of new rigid sternal plates and prediction of sternal dehiscence in high-risk patients
Background: Sternal dehiscence is a serious complication of cardiac surgery that has been a clinically intractable problem. The study aimed to explore the advanta...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical a...
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Abstract Introduction Tarlatamab is a Delta-like ligand 3 (DLL3) -directed bispecific T-cell engager recently approved for use in patients with advanced small cell lung cancer (SCL...
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract Introduction Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...

Back to Top