Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Environmental impact of single-use, reusable, and mixed trocar systems used for laparoscopic cholecystectomies

View through CrossRef
Introduction Climate change is one of the 21st century’s biggest public health issues and health care contributes up to 10% of the emissions of greenhouse gases in developed countries. About 15 million laparoscopic procedures are performed annually worldwide and single-use medical equipment is increasingly used during these procedures. Little is known about costs and environmental footprint of this change in practice. Methods We employed Life Cycle Assessment method to evaluate and compare the environmental impacts of single-use, reusable, and mixed trocar systems used for laparoscopic cholecystectomies at three hospitals in southern Sweden. The environmental impacts were calculated using the IMPACT 2002+ method and a functional unit of 500 procedures. Monte Carlo simulations were used to estimate differences between trocar systems. Data are presented as medians and 2.5th to 97.5th percentiles. Financial costs were calculated using Life Cycle Costing. Results The single-use system had a 182% higher impact on resources than the reusable system [difference: 5160 MJ primary (4400–5770)]. The single-use system had a 379% higher impact on climate change than the reusable system [difference: 446 kg CO2eq (413–483)]. The single-use system had an 83% higher impact than the reusable system on ecosystem quality [difference: 79 PDF*m2*yr (24–112)] and a 240% higher impact on human health [difference: 2.4x10-4 DALY/person/yr (2.2x10-4-2.6x10-4)]. The mixed and single-use systems had a similar environmental impact. Differences between single-use and reusable trocars with regard to resource use and ecosystem quality were found to be sensitive to lower filling of machines in the sterilization process. For ecosystem quality the difference between the two were further sensitive to a 50% decrease in number of reuses, and to using a fossil fuel intensive electricity mix. Differences regarding effects on climate change and human health were robust in the sensitivity analyses. The reusable and mixed trocar systems were approximately half as expensive as the single-use systems (17360 € and 18560 € versus 37600 €, respectively). Conclusion In the Swedish healthcare system the reusable trocar system offers a robust opportunity to reduce both the environmental impact and financial costs for laparoscopic surgery.
Title: Environmental impact of single-use, reusable, and mixed trocar systems used for laparoscopic cholecystectomies
Description:
Introduction Climate change is one of the 21st century’s biggest public health issues and health care contributes up to 10% of the emissions of greenhouse gases in developed countries.
About 15 million laparoscopic procedures are performed annually worldwide and single-use medical equipment is increasingly used during these procedures.
Little is known about costs and environmental footprint of this change in practice.
Methods We employed Life Cycle Assessment method to evaluate and compare the environmental impacts of single-use, reusable, and mixed trocar systems used for laparoscopic cholecystectomies at three hospitals in southern Sweden.
The environmental impacts were calculated using the IMPACT 2002+ method and a functional unit of 500 procedures.
Monte Carlo simulations were used to estimate differences between trocar systems.
Data are presented as medians and 2.
5th to 97.
5th percentiles.
Financial costs were calculated using Life Cycle Costing.
Results The single-use system had a 182% higher impact on resources than the reusable system [difference: 5160 MJ primary (4400–5770)].
The single-use system had a 379% higher impact on climate change than the reusable system [difference: 446 kg CO2eq (413–483)].
The single-use system had an 83% higher impact than the reusable system on ecosystem quality [difference: 79 PDF*m2*yr (24–112)] and a 240% higher impact on human health [difference: 2.
4x10-4 DALY/person/yr (2.
2x10-4-2.
6x10-4)].
The mixed and single-use systems had a similar environmental impact.
Differences between single-use and reusable trocars with regard to resource use and ecosystem quality were found to be sensitive to lower filling of machines in the sterilization process.
For ecosystem quality the difference between the two were further sensitive to a 50% decrease in number of reuses, and to using a fossil fuel intensive electricity mix.
Differences regarding effects on climate change and human health were robust in the sensitivity analyses.
The reusable and mixed trocar systems were approximately half as expensive as the single-use systems (17360 € and 18560 € versus 37600 €, respectively).
Conclusion In the Swedish healthcare system the reusable trocar system offers a robust opportunity to reduce both the environmental impact and financial costs for laparoscopic surgery.

Related Results

Trocar localisation for robot-assisted vitreoretinal surgery
Trocar localisation for robot-assisted vitreoretinal surgery
Abstract Purpose Robot-assisted vitreoretinal surgery provides precise and consistent operations on the back of the eye. To perform this safely, kno...
Trocar Site Hernia after Laparoscopic Colectomy: A Case Report and Literature Review
Trocar Site Hernia after Laparoscopic Colectomy: A Case Report and Literature Review
Background. Trocar Site Hernia (TSH) is defined as an incisional hernia which occurs after minimally invasive surgery on the trocar incision site.In 2004 Tonouchi classified trocar...
Laparoscopic cholecystectomy in Jos: Prospects and perspectives
Laparoscopic cholecystectomy in Jos: Prospects and perspectives
Abstract Laparoscopic cholecystectomy is now done in a lot more private and public hospital settings presently in low-income countries, particularly sub-Saharan Africa. T...
A <span aria-describedby="tippy-18">Comparison of Clinical Outcomes of Robot-Assisted and Conventional Laparoscopic Surgery
A <span aria-describedby="tippy-18">Comparison of Clinical Outcomes of Robot-Assisted and Conventional Laparoscopic Surgery
Background: Robot-assisted laparoscopic surgery robot-assisted surgical system has gained significant popularity over open and laparoscopic interventions. However, given its high c...
The Almodin–Moron Trocar for Uterine Entry during Fetal Surgery
The Almodin–Moron Trocar for Uterine Entry during Fetal Surgery
<i>Objective: </i>Compare the use of a newly designed and reusable metal trocar for initial uterine entry with the disposable Tulipan–Bruner trocar in creation of a hys...
Outcome of laparoscopy assisted pancreaticoduodenectomy at the department of gastrointestinal surgery, Viet Duc University Hospital
Outcome of laparoscopy assisted pancreaticoduodenectomy at the department of gastrointestinal surgery, Viet Duc University Hospital
Abstract Introduction: Laparoscopic-assisted pancreaticoduodenectomy is a complex surgical procedure associated with a high rate of complications, particularly those arising from...
Evaluation of difficulties in laparoscopic cholecystectomy
Evaluation of difficulties in laparoscopic cholecystectomy
Introduction. For decades, laparoscopic cholecystectomy has been the gold standard in surgical treatment of patients with cholelithiasis all over the world. The main advantag...

Back to Top