Three-Dimensional Printing of a Transconjunctival Vitrectomy Trocar-Cannula System

View through CrossRef
<b><i>Purpose:</i></b> The aim of this paper was to study the feasibility of manufacturing a customizable trocar-cannula system for vitreoretinal surgery utilizing commercially available three-dimensional (3D) printing technology. <b><i>Methods:</i></b> A digital model of a trocar-cannula system for vitreoretinal surgery was created using computer-aided design (CAD) software and printed utilizing a laser-sintering 3D printer in modified ABS thermoplastic material. The trocar-cannula prototypes were tested in pig eyes. <b><i>Results:</i></b> A customizable digital model was created using commercially available CAD software. Three trocar-cannulas were printed. The smallest cannulas that could be printed had dimensions between 21 and 22G. The trocar-cannulas were inserted in pig eyes after performing sclerotomies with a commercially available 20G MVR blade. One cannula broke during insertion. <b><i>Conclusions:</i></b> This study demonstrates the feasibility of printing a transconjunctival vitrectomy trocar-cannula system with commercially available 3D print technology. The 3D printer and build material used resulted in trocar-cannulas with functional limitations including a minimum size achievable and mechanical resistance.
Title: Three-Dimensional Printing of a Transconjunctival Vitrectomy Trocar-Cannula System
Description:
<b><i>Purpose:</i></b> The aim of this paper was to study the feasibility of manufacturing a customizable trocar-cannula system for vitreoretinal surgery utilizing commercially available three-dimensional (3D) printing technology.
<b><i>Methods:</i></b> A digital model of a trocar-cannula system for vitreoretinal surgery was created using computer-aided design (CAD) software and printed utilizing a laser-sintering 3D printer in modified ABS thermoplastic material.
The trocar-cannula prototypes were tested in pig eyes.
<b><i>Results:</i></b> A customizable digital model was created using commercially available CAD software.
Three trocar-cannulas were printed.
The smallest cannulas that could be printed had dimensions between 21 and 22G.
The trocar-cannulas were inserted in pig eyes after performing sclerotomies with a commercially available 20G MVR blade.
One cannula broke during insertion.
<b><i>Conclusions:</i></b> This study demonstrates the feasibility of printing a transconjunctival vitrectomy trocar-cannula system with commercially available 3D print technology.
The 3D printer and build material used resulted in trocar-cannulas with functional limitations including a minimum size achievable and mechanical resistance.

Related Results

Effectiveness of Protocol Based Nursing Care of Patients with Intravenous Line Cannula in Selected Hospital at Ambala City
Effectiveness of Protocol Based Nursing Care of Patients with Intravenous Line Cannula in Selected Hospital at Ambala City
Health team members are always bound to be right for the betterment of patient, but when it becomes difficult to keep up there comes the need for a guidance to lead them on the rig...
The Glowport – Illuminated vitrectomy trocar cannulas
The Glowport – Illuminated vitrectomy trocar cannulas
The use of small-gauge trocar cannulas during transconjunctival sutureless pars plana vitrectomy (PPV) facilitates the smooth transition of instruments into the posterior segment a...
Trocar localisation for robot-assisted vitreoretinal surgery
Trocar localisation for robot-assisted vitreoretinal surgery
Abstract Purpose Robot-assisted vitreoretinal surgery provides precise and consistent operations on the back of the eye. To perform this safely, kno...
Impact of Cannula Size on Clinical Outcomes in Peripheral Venoarterial Extracorporeal Membrane Oxygenation
Impact of Cannula Size on Clinical Outcomes in Peripheral Venoarterial Extracorporeal Membrane Oxygenation
Venoarterial extracorporeal membrane oxygenation (VA ECMO) is an effective mechanical circulatory support for cardiopulmonary failure. Conventionally, an arterial cannula over 15 F...
The Role of Vitrectomy in Threatment of Epimacular Fibrosis
The Role of Vitrectomy in Threatment of Epimacular Fibrosis
Purpose:а comparison of the results of epimacular fibrosis surgical treatment with vitrectomy and without it.Patients and methods. Two groups of patients with epimacular  fibrosis ...
Transconjunctival sutureless 20G
Transconjunctival sutureless 20G
Abstract Purpose To evaluate a trocar system that allows the use of the regular 20‐gauge vitrectomy instruments for a transconjunctival sutureless surgery for the treatment of vari...
Trocar Site Hernia after Laparoscopic Colectomy: A Case Report and Literature Review
Trocar Site Hernia after Laparoscopic Colectomy: A Case Report and Literature Review
Background. Trocar Site Hernia (TSH) is defined as an incisional hernia which occurs after minimally invasive surgery on the trocar incision site.In 2004 Tonouchi classified trocar...